CardioPulse: developments in the treatment of aortic aneurysms in 2014

2015

Since the introduction of EndoVascular Aortic Repair (EVAR) for the treatment of abdominal aortic aneurysms (AAA) more than 20 years ago, the technique has evolved rapidly, from tubular grafts for fairly simple abdominal aortic anatomy, to bifurcated, fenestrated, branched, or parallel grafts for complex aortic aneurysms, no longer confined to the infrarenal abdominal aorta.

Aortic Aneurysm ThoracicAortic RuptureEndovascular ProceduresBiomedical Technology610 Medicine & healthEquipment DesignSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis10020 Clinic for Cardiac SurgeryBlood Vessel Prosthesis ImplantationHumansaortic aneurysmAortic Aneurysm Abdominal
researchProduct

Early results of a low-profile stent-graft for thoracic endovascular aortic repair

2020

Purpose To assess outcomes of a low-profile thoracic stent-graft in the treatment of thoracic aortic pathologies. Methods A retrospective analysis of all consecutive patients with aortic thoracic pathologies treated with the RelayPro device in two university hospitals between October 2018 and July 2019. Results 23 patients (65% men; mean age 63.4 ± 15 years) were treated. Pathologies included aortic dissections (n = 10), 5 residual type A (22%) and 5 type B (22%), 6 degenerative aortic aneurysms (26%), 4 penetrating aortic ulcers (17%), and aortic erosion, intramural hematoma and aortic rupture (n = 1 and 4% in each case). Two cases (9%) were emergent and two urgent. Proximal landing was a…

Aortic archElephant trunksEndoleakCardiovascular ProceduresPhysiologymedicine.medical_treatmentVascular SurgeryAorta ThoracicPathology and Laboratory MedicineNervous SystemPostoperative ComplicationsMedicine and Health SciencesLeukocytosisAortaCerebrospinal FluidAged 80 and overMultidisciplinaryQRArteriesMiddle AgedBody FluidsTreatment OutcomeMedicineEngineering and TechnologyFemaleStentsmedicine.symptomAnatomyResearch ArticleBiotechnologymedicine.medical_specialtyScienceAortic DiseasesBioengineeringSurgical and Invasive Medical ProceduresBlood Vessel Prosthesis Implantationmedicine.arterymedicineHumansAortic ruptureAgedRetrospective StudiesAortabusiness.industryStentBiology and Life SciencesVascular surgerySurgeryAppositionSurgical RepairAnatomical PathologyCardiovascular AnatomyBlood VesselsMedical Devices and EquipmentbusinessPLoS ONE
researchProduct

Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…

2012

Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…

Aortic archEndoleakMedizinAnastomotic LeakAorta ThoracicChest painPatient Care PlanningAortic aneurysmPostoperative ComplicationsIntraoperative ComplicationsBrain DiseasesEndovascular ProceduresAngiographyEquipment DesignGeneral MedicineTreatment OutcomeCardiothoracic surgeryDescending aortacardiovascular systemCardiologyStentsmedicine.symptomCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialtyConsensusAortic DiseasesPerioperative CareSpinal Cord DiseasesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryInternal medicineMonitoring IntraoperativemedicineHumansAortaAortic Aneurysm Thoracicbusiness.industryContraindicationsPatient SelectionVascular System Injuriesmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic DissectionSurgerybusinessTomography X-Ray ComputedEchocardiography TransesophagealEuropean Journal of Cardio-Thoracic Surgery
researchProduct

Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse

2011

OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…

Aortic archMalemedicine.medical_specialtyAortographymedicine.medical_treatmentHemodynamicsAorta ThoracicFOS: Medical engineeringProsthesis DesignAortographyBlood Vessel Prosthesis ImplantationImaging Three-DimensionalBlood vessel prosthesismedicine.arteryMaterials TestingmedicineHumansComputer Simulationthoracic aortic stent graft (TASG)Aortamedicine.diagnostic_testbusiness.industryEndovascular ProceduresHemodynamicsModels CardiovascularStentSettore ING-IND/34 - Bioingegneria Industrialenutritional and metabolic diseases90399 Biomedical Engineering not elsewhere classifiedCurvatures of the stomachSurgeryBiomechanical PhenomenaBlood Vessel ProsthesisProsthesis FailureEquipment Failure AnalysisRegional Blood FlowRadiographic Image Interpretation Computer-AssistedStentslipids (amino acids peptides and proteins)SurgeryStress Mechanicalbiological phenomena cell phenomena and immunitybusinessNuclear medicineTomography X-Ray ComputedCardiology and Cardiovascular MedicinePerfusionAlgorithmsJournal of Vascular Surgery
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Outcomes of aortic valve repair according to valve morphology and surgical techniques

2012

OBJECTIVES: The aim of this study was to assess the impact of aortic valve morphology and different surgical aortic valve repair techni- ques on long-term clinical outcomes. METHODS: Between February 2003 and May 2010, 216 patients with aortic insufficiency underwent aortic valve repair in our institu- tion. Ages ranged between 26 and 82 years (mean 53 ± 15 years). Aortic valve dysfunctions, according to functional classification, were: type I in 55 patients (25.5%), type II in 126 (58.3%) and type III in 35 (16.2%). Sixty-six patients (27.7%) had a bicuspid valve. Aortic valve repair techniques included sub-commissural plasty in 138 patients, plication in 84, free-edge reinforcement in 80,…

Aortic valveMaleTime Factorsmedicine.medical_treatmentKaplan-Meier EstimateAortic valve repairRecurrenceRisk FactorsMitral valve80 and overHospital MortalityCoronary Artery BypassAortaUltrasonographyAged 80 and overTricuspid valveCalcinosisCardiac Valve AnnuloplastyMiddle AgedAortic valve repair • Bicuspid aortic valve • Tricuspid aortic valve • Aortic annulus stabilization medicine.anatomical_structureTreatment OutcomeAortic ValveReplantationcardiovascular systemCardiologyChordae TendineaeMitral ValveFemaleChordae tendineaeCardiology and Cardiovascular MedicineAdult; Aged; Aged 80 and over; Aorta; Aortic Valve; Aortic Valve Insufficiency; Blood Vessel Prosthesis Implantation; Calcinosis; Chordae Tendineae; Coronary Artery Bypass; Disease-Free Survival; Female; Hospital Mortality; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Mitral Valve; Proportional Hazards Models; Recurrence; Replantation; Risk Assessment; Risk Factors; Time Factors; Treatment Outcome; Ultrasonography; Cardiac Valve Annuloplasty; Suture TechniquesPulmonary and Respiratory MedicineAdultmedicine.medical_specialtyAortic Valve InsufficiencyRisk AssessmentCardiac Valve AnnuloplastyDisease-Free SurvivalBlood Vessel Prosthesis ImplantationBicuspid valveInternal medicinemedicineHumansAgedProportional Hazards ModelsMitral valve repairbusiness.industrySuture TechniquesSettore MED/23 - Chirurgia CardiacaOriginal ArticlesSurgerySurgerybusiness
researchProduct

Large platelets but not putative endothelial progenitor cells are associated with low strut coverage after drug-eluting stent implantation

2015

Objectives This study assessed whether different subsets of circulating endothelial and putative endothelial progenitor cells (CEC and EPC) correlate with stent strut coverage (SSC) using second generation optical coherence tomography (OCT). Background Due to the lack of imaging modalities with a resolution down to the magnitude of a few cells, the influence of EPC on endothelialisation of drug-eluting stents has not been assessed in patients. Methods In 37 patients, SSC of everolimus-eluting stents was assessed by OCT 5-7months after stent implantation. Different subsets of EPC (CD34(+)KDR(+), CD34(+)KDR(+)CD45(dim), CD133(+), CD3(+)CD31(+)), CEC (CD31(+)CD45(-)CD146(+)), and CD31(+)CD45(-…

Blood PlateletsMaleCD31medicine.medical_specialtymedicine.medical_treatmentCD34UrologyFlow cytometryBlood Vessel Prosthesis ImplantationAntigens CDmedicineHumansPlateletEverolimusProgenitor cellAgedEndothelial Progenitor Cellsmedicine.diagnostic_testbusiness.industryStentDrug-Eluting StentsKinase insert domain receptorMiddle AgedFlow CytometryVascular Endothelial Growth Factor Receptor-2Drug-eluting stentImmunologycardiovascular systemFemaleCardiology and Cardiovascular MedicinebusinessImmunosuppressive AgentsTomography Optical CoherenceInternational Journal of Cardiology
researchProduct

Mortality of ruptured abdominal aortic aneurysm with selective use of endovascular repair

2009

The aim of this review was to examine the results over a seven-year period of treatment for ruptured abdominal aortic aneurysm (RAAA). From 2002 on, our tertiary referral centre offered both open and endovascular (EVAR) treatment modalities for RAAA. All patients with a proven RAAA who were admitted into our hospital were included. Primary outcome measure was surgical mortality. In total 261 patients were admitted with suspicion of acute AAA. Of these, 175 (67%) had a RAAA, confirmed by computed tomography-scanning or at laparotomy. One hundred and fifty-nine patients (90.9%) were treated, 114 by open repair and 45 by EVAR. Overall mortality of patients treated was 25.2%, with an open repai…

Blood Vessel Prosthesis ImplantationTime FactorsTreatment Outcomeabdominal aortic aneurysmsurgical mortalityAortic RuptureHemodynamicsHumansendovascular repairTomography X-Ray ComputedAortographySettore MED/22 - Chirurgia VascolareAortic Aneurysm Abdominal
researchProduct

External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.

2007

Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigat…

Carotid Artery Diseasesmedicine.medical_specialtyCarotid Artery CommonCarotid arteriesmedicine.medical_treatmentPolyesters030232 urology & nephrologyBiomedical EngineeringMedicine (miscellaneous)BioengineeringVein graft030204 cardiovascular system & hematologyDistensionBiomaterials03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineMedicineAnimalsSaphenous VeinNeointimal hyperplasiaPolyester meshHyperplasiaSheepbusiness.industryGraft Occlusion VascularStentGeneral MedicineSurgical Meshequipment and suppliesmedicine.diseaseSurgeryCompliance (physiology)Disease Models Animalsurgical procedures operativeSurgical meshStentsbusinessTunica IntimaDilatation PathologicThe International journal of artificial organs
researchProduct

The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…

2012

The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…

Clinical Trials as TopicEvidence-Based Medicine10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Procedures610 Medicine & healthProsthesis DesignRisk Assessment2705 Cardiology and Cardiovascular Medicine10020 Clinic for Cardiac Surgery2746 SurgeryBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationTreatment OutcomeRisk FactorsHumansStentsClinical CompetenceRegistriesLearning Curvestents endovascular procedures aortic aneurysm abdominalAortic Aneurysm Abdominal
researchProduct