Search results for "CALIBRATION"
showing 10 items of 890 documents
Analysis and calibration of absorptive images of Bose-Einstein condensate at non-zero temperatures
2008
We describe the method allowing quantitative interpretation of absorptive images of mixtures of BEC and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.
The energy calibration of LEP in the 1993 scan
1995
This report summarizes the procedure for providing the absolute energy calibration of the LEP beams during the energy scan in 1993. The average beam energy around the LEP ring was measured in 25 calibrations with the resonant depolarization technique. The time variation of this average beam energy is well described by a model of the accelerator based on monitored quantities. The absolute calibration of the centre of mass energies of the off-peak points is determined with a precision of 2 parts in 10(5) resulting in a systematic error on the Z-mass of about 1.4 MeV and on the Z-width of about 1.5 MeV.
Calibration of the NEXT-White detector using 83m Kr decays
2018
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterr'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83mKr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for …
Atmospheric turbulence in phase-referenced and wide-field interferometric images
2010
Phase referencing is a standard calibration procedure in radio interferometry. It allows us to detect weak sources by using quasisimultaneous observations of closeby sources acting as calibrators. However, atmospheric turbulence may introduce strong differences in the optical paths of the signals of the target and calibrator and affect, or even waste, phase referencing in cases of relatively large calibrator-to-target separations and/or bad weather. The situation is similar in wide-field interferometric observations. We present the results of a Monte Carlo study of the astrometric precision and sensitivity of an interferometric array (a realization of the Square Kilometre Array, SKA) in pha…
A single stage adiabatic demagnetization refrigerator for testing x-ray microcalorimeters
2004
A single stage Adiabatic Demagnetization Refrigerator (ADR), has been set-up at the X-ray Astronomy Calibration and Testing (XACT) facility of INAF - Osservatorio Astronomico di Palermo G.S. Vaiana, for the development and testing of cryogenic X-ray detectors for laboratory and astrophysical applications. The ADR allows to cool detectors at temperatures below 40 mK and to maintain them at constant operating temperature for many hours. We describe the design and construction of the ADR and present test results and performances.
Calibration of the XRT-SOLARB flight filters at the XACT facility of INAF-OAPA
2004
The X-Ray Telescope (XRT) experiment on-board the Japanese satellite SOLAR-B (launch in 2006) aimed at providing full Sun field of view at ~ 1.5" angular resolution, will be equipped with two wheels of focal-plane filters to select spectral features of X-ray emission from the Solar corona, and a front-end filter to significantly reduce the visible light contamination. We present the results of the X-ray calibrations of the XRT flight filters performed at the X-ray Astronomy Calibration and Testing (XACT) facility of INAF-OAPA. We describe the instrumental set-up, the adopted measurement technique, and present the transmission vs. energy and position measurements.
Calibration of the XRT-SOLARB flat mirror samples at the XACT Facility of INAF-OAPA
2004
The X-Ray Telescope (XRT) experiment on-board the Japanese satellite SOLAR-B (launch in 2006) is equipped with a modified Wolter I grazing incidence X-ray telescope (focal length 2700 mm) to image the full Sun at ~ 1.5" angular resolution onto a 2048 x 2048 back illuminated CCD focal plane detector. The X-ray telescope consisting of one single reflecting shell is coated with ion beam sputtered Iridium over a binding layer of Chromium to provide nearly 5 square centimetres effective area at 60 A. We present preliminary results of X-ray calibrations of the XRT flat mirror samples performed at the X-ray Astronomy Calibration and Testing (XACT) facility of INAF-OAPA. We describe the instrumenta…
The Palermo XACT facility: a new 35 m long soft x-ray beam-line for the development and calibration of next-generation x-ray observatories
2006
The X-ray Astronomy Calibration and Testing (XACT) facility of the Instituto Nazionale di Astrofisica (INAF) at Osservatorio Astronomico di Palermo has recently undergone a major upgrade with the design and construction of a 35 meter long vacuum beam-line operating in the soft X-rays (0.1-20 keV) and the addition of new hardware to meet the requirements for testing and calibration of next generation X-ray missions. We report on the present configuration of the facility and briefly survey the range of its applications.
The AB Doradus system revisited: The dynamical mass of AB Dor A/C
2017
We report new radio interferometric observations of the quadruple pre-main-sequence (PMS) system ABD oradus. From these observations, combined with existing VLT near-infrared relative astrometry, we have refined the estimates of the dynamical masses of the system. In particular, we find component masses of 0.86 ± 0.09M⊙ and 0.090 ± 0.003M⊙ for ABD or A and ABD or C, respectively. These dynamical masses, coupled with temperatures and luminosities, allow for comparison with theoretical stellar models. The case of ABDorC, in terms of calibration of evolutionary models of low-mass young stars has been widely reported in previous studies. In this contribution, we compare the measured properties …
Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters
2013
After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons lear…