Search results for "CEM"

showing 10 items of 3487 documents

Reaction of the bone structure to methotrexate-Palacos flow y. Experimental investigations in animals.

1989

With the combined osteosynthesis of pathological fractures in association with tumors and/or metastases in mind, E. Merck (Darmstadt, FRG) developed a bone cement containing a cytostatic agent, methotrexate-Palacos flow y (MTX-Pf). The animal-experimental study presented here investigates the tolerability of MTX-Pf in the femurs of rabbits with lateral comparison. In these investigations we used both the concentration of 0.63% MTX, as is currently used in standard clinical surgery, as well as a much higher concentration of 2.5% MTX. The histological sections were investigated using microradiographic methods and provided no indication of any significant differences between the femora with th…

musculoskeletal diseasesmedicine.medical_specialtyBone and BonesFractures BoneMedicineAnimalsOrthopedics and Sports Medicineskin and connective tissue diseasesWound HealingOsteosynthesisbusiness.industryBone CementsGeneral MedicineBone cementSurgeryFracture Fixation IntramedullaryMethotrexateTolerabilityOrthopedic surgerySurgeryMethotrexateRabbitsPathological fracturesbusinessBone structuremedicine.drugArchives of orthopaedic and trauma surgery
researchProduct

The PROMISE study protocol: a multicenter prospective study of process optimization with interdisciplinary and cross-sectoral care for German patient…

2021

Background and purpose — Knee and hip replacement are common and increasing procedures, and an optimized care process that could be implemented in different settings would be useful. The PROMISE trial investigates whether a new care process works equally in different German settings and how the results compare with current non-standardized care. Patients and methods — This multi-center prospective mixed-method study includes 2,000 German patients receiving arthritis-related hip or knee endoprostheses. An interdisciplinary and cross-sectoral care process was developed and implemented in 3 German hospitals with different levels of care, and corresponding rehabilitation centers were included t…

musculoskeletal diseasesmedicine.medical_specialtyCare processArthroplasty Replacement HipMEDLINEHip replacement (animal)German03 medical and health sciencesDisability Evaluation0302 clinical medicineGermanySurveys and QuestionnairesmedicineHumansOrthopedics and Sports Medicine030212 general & internal medicineProspective StudiesProspective cohort studyArthroplasty Replacement KneePain MeasurementProtocol (science)Orthopedic surgeryPatient Care Team030222 orthopedicsbusiness.industryGeneral MedicineProstheses and Implantslanguage.human_languageTreatment OutcomeCross sectorallanguagePhysical therapyQuality of LifeSurgerybusinessRD701-811Research ArticleActa Orthopaedica
researchProduct

The Epidemiology of Hip and Knee Primary and Revision Arthroplasties during the COVID-19 Pandemic

2021

Background: The purpose of this study was to provide a comprehensive assessment of the impact of the COVID-19 pandemic on the epidemiology of primary and revision arthroplasties of the hip and knee joint. Methods: This study compared the data on knee and hip arthroplasty procedures from 2 hospitals (primary and revision) conducted in two periods: the period of the COVID-19 pandemic in Poland (from 4 March 2020 to 15 October 2020) and the corresponding period prior to the pandemic (from 4 March 2019 to 15 October 2019). We compared the epidemiological data, demographic data, and hospital stay duration data from these two periods. Results: Our analysis demonstrated that the total number of hi…

musculoskeletal diseasesmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)Leadership and Managementmedicine.medical_treatmentKnee replacementHealth InformaticsSARS-COV-2Knee JointArticle03 medical and health sciences0302 clinical medicineHealth Information ManagementEpidemiologyPandemicmedicineDuration data030222 orthopedicsknee revisionknee arthroplastiesbusiness.industryhip arthroplastiesHealth Policypandemiclock-downR030229 sport sciencesArthroplastySurgeryOrthopedic surgeryMedicineepidemiologyhip revisionbusinessCovid-19knee arthroplasties; hip arthroplasties; knee revision; hip revision; Covid-19; epidemiology; lock-down; pandemic; SARS-COV-2Healthcare
researchProduct

Optimal positioning of the humeral component in the reverse shoulder prosthesis.

2014

Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…

musculoskeletal diseasesmedicine.medical_specialtyFEM analysesmedicine.medical_treatmentReplacementDeltoid curveProsthesis DesignProsthesisArthroplastyArthropathymedicineHumansOrthopedics and Sports MedicineHumerusRotator cuffArthroplasty ReplacementSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeTotal reverse shoulder arthroplasty Intrinsic stability FEM analyses Polyethylene wear Stability ratioFEM analyses; Intrinsic stability; Polyethylene wear; Stability ratio; Total reverse shoulder arthroplasty; Arthroplasty Replacement; Humans; Humerus; Prosthesis Design; Shoulder Joint; Orthopedics and Sports Medicine; Surgery; Medicine (all)business.industryShoulder JointMedicine (all)Intrinsic stabilityHumerusShoulder Prosthesismedicine.diseaseArthroplastySurgerymedicine.anatomical_structurePolyethylene wearStability ratioTotal reverse shoulder arthroplastySurgeryShoulder jointbusinesshuman activitiesMusculoskeletal surgery
researchProduct

Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences

2020

Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…

musculoskeletal diseasesmedicine.medical_specialtyKinematicsKnee Jointmedicine.medical_treatmentComparisonKinematicsPromProsthesis DesignProsthesis03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicinePosterior-stabilized kneeRange of Motion ArticularSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeArthroplasty Replacement KneeOrthodontics030222 orthopedicsKnee laxitybusiness.industryTKAPosterior stabilized030229 sport sciencesKinematicmusculoskeletal systemNavigationBiomechanical PhenomenaSurgeryCohortOrthopedic surgerySurgeryMobile bearingKnee ProsthesisRange of motionbusinessMUSCULOSKELETAL SURGERY
researchProduct

Patient Specific Instrumentation for Total Knee Arthroplasty: a Literature Review

2014

During the past decade, total knee arthroplasty (TKA) has been markedly increased. Recently, patient-specific custom cutting guides have been commercially introduced in order to achieve an accurate component alignment during TKA. In fact, these cutting blocks are specific to a patient’s knee anatomy and should help the surgeons to perform bone cuts, reducing the complexity of conventional alignment and sizing tools. Nevertheless, there are critical arguments against patient-specific cutting guides for routine use, such as poor evidence and higher costs. Additionally, there are still no mild and long-term results available that describe the clinical outcomes following patient-specific instru…

musculoskeletal diseasesmedicine.medical_specialtyKnee JointTotal knee arthroplastytotal knee arthroplasty patient specific instrumentation PSI knee ProsthesisSettore MED/33 - Malattie Apparato LocomotoreMedicineHumansOrthopedics and Sports MedicineComponent alignmentInstrumentation (computer programming)Arthroplasty Replacement KneeEvidence-Based Medicinebusiness.industryMagnetic Resonance ImagingSurgeryTreatment OutcomePatient specific instrumentationSurgery Computer-AssistedOrthopedic surgeryPractice Guidelines as TopicPhysical therapySurgerybusinessKnee ProsthesisTomography X-Ray Computed
researchProduct

Herniation of an intervertebral disc with cauda compression syndrome in childhood.

1979

A case of a lumbosacral disc herniation of traumatic origin with compression of the cauda equina in a child is reported. The problems of early diagnosis, timely operative procedure, and prognosis of neurological deficit of operated disc herniation in childhood are discussed.

musculoskeletal diseasesmedicine.medical_specialtyNeurologyDisc herniationLumbar VertebraeCauda Equinabusiness.industryCauda equinaIntervertebral discCompression (physics)Surgerymedicine.anatomical_structureNeurologymedicineHumansParalysisFemaleNeurology (clinical)businessChildSpinal Cord CompressionLumbosacral jointIntervertebral Disc DisplacementNeuroradiologyNeurological deficitJournal of neurology
researchProduct

Molekulare Signalwege der aseptischen Endoprothesenlockerung (Molecular pathways in aseptic loosening of orthopaedic endoprosthesis)

2008

Operative joint replacement to treat disabling joint conditions secondary to degenerative and inflammatory arthritides has become one of the most efficacious and cost-effective procedures to relieve pain and restore joint function. However, prosthetic implants are not built to last forever and osteolysis and aseptic loosening has been associated with prosthetic arthroplasties since their introduction. The functional life of a synthetic joint is influenced by many factors including the material of the implant, operation procedures and the surgeon involved, as well as patient-related factors. Although promising developments have been achieved in this field, more than 10% of all implants still…

musculoskeletal diseasesmedicine.medical_specialtyOsteolysisSignal Pathwaysbusiness.industryJoint replacementmedicine.medical_treatment10051 Rheumatology Clinic and Institute of Physical MedicineBiomedical EngineeringAseptic loosening2204 Biomedical EngineeringImplant failure610 Medicine & healthmedicine.diseaseSurgeryProsthetic implantsMedicineSmall particlesImplantbusiness
researchProduct

Joint contractures in the absence of inflammation may indicate mucopolysaccharidosis

2009

Abstract Background Undiagnosed patients with the attenuated form of mucopolysaccharidosis (MPS) type I often have joint symptoms in childhood that prompt referral to a rheumatologist. A survey conducted by Genzyme Corporation of 60 European and Canadian rheumatologists and pediatric rheumatologists demonstrated that Bone and joint manifestations are prominent among most patients with MPS disorders. These life-threatening lysosomal storage diseases are caused by deficient activity of specific enzymes involved in the degradation of glycosaminoglycans. Patients with attenuated MPS disease often experience diagnostic delays. Enzyme replacement therapy is now commercially available for MPS I (l…

musculoskeletal diseasesmedicine.medical_specialtyPediatricscongenital hereditary and neonatal diseases and abnormalitieslcsh:Diseases of the musculoskeletal systemIdursulfaseMucopolysaccharidosisDiseaseRheumatologyInternal medicinemedicineImmunology and AllergyPediatrics Perinatology and Child HealthYoung adultCarpal tunnel syndromeskin and connective tissue diseasesbusiness.industrylcsh:RJ1-570nutritional and metabolic diseaseslcsh:PediatricsEnzyme replacement therapyHypothesismedicine.diseaseRheumatologyJoint painPediatrics Perinatology and Child Healthmedicine.symptomlcsh:RC925-935businessmedicine.drugPediatric Rheumatology
researchProduct

Reconstruction of vertebral body in thoracolumbar AO type A post-traumatic fractures by balloon kyphoplasty: a series of 85 patients with a long foll…

2019

Background Traumatic fractures of the thoracolumbar spine are common injuries, accounting for approximately 90% of all spinal traumas. Optimal management of these fractures still gives rises to much debate in the literature. Currently, one of the treatment options in young patients with stable traumatic vertebral fractures is conservative treatment using braces. Kyphoplasty as a minimally invasive procedure has been shown to be effective in stabilizing vertebral body fractures, resulting in immediate pain relief and improved physical function with early return to work activity. The aim of the study is to report VAS, ODI scores, and kyphosis correction following treatment. Methods This is a …

musculoskeletal diseasesmedicine.medical_specialtyPercutaneousVertebral BodyKyphosisPainBalloonFractures CompressionMedicineHumansKyphoplastyRetrospective StudiesCobb anglebusiness.industryBone CementsRetrospective cohort studymedicine.diseaseSurgeryOswestry Disability IndexTreatment OutcomeRadiological weaponCohortSpinal FracturesSurgeryNeurology (clinical)businessFollow-Up StudiesJournal of neurosurgical sciences
researchProduct