Search results for "CHAMBER"

showing 10 items of 359 documents

Combined effects of type and depth of counting chamber, and rateof image frame capture, on bull sperm motility and kinematics

2019

Semen quality assessment requires accurate, reliable and objective methods for examination of sperm variables including sperm motility. For preparation of semen samples for artificial insemination, as a genetic resource, samples that are used for insemination need to have the capacity to result in a highly acceptable fertility rate. Several methods have been developed for evaluation of bull sperm in laboratory conditions and for preparation of doses for artificial insemination. Computer-assisted semen analyses can provide objective information on various sperm variables. Nevertheless, this equipment requires fine-calibrations considering differences among species, breeds and conditions for …

Maleendocrine systemmedicine.medical_treatmentSemenKinematicsBreedingBiologyInseminationSperm kinematics03 medical and health sciencesSemen quality0302 clinical medicineEndocrinologyFood AnimalsStatisticsBull breedImage Processing Computer-AssistedmedicineAnimalsInsemination ArtificialSperm motility030219 obstetrics & reproductive medicineSperm Counturogenital systemArtificial insemination0402 animal and dairy science04 agricultural and veterinary sciencesGeneral MedicineSpermatozoa040201 dairy & animal scienceSpermBreedBiomechanical PhenomenaSemen AnalysisCattleAnimal Science and ZoologyCASA-MotCapture frame rateCounting chamber
researchProduct

Pupil size differences between female and male patients after cataract surgery.

2022

Purpose To evaluate the changes in pupil diameter in women and men after cataract surgery. The correlation of pupillary changes with the variables age and anterior chamber depth will be analyzed. Methods The values of 109 randomized eyes who underwent cataract surgery were obtained and divided into two groups, 71 women and 38 men. Pupil diameter was measured preoperatively and 3-months postoperatively using the pupillometer software of the Topolyzer Vario (Wavelight Laser Technologie AG). Anterior chamber depth was obtained with Pentacam® (Oculus). Differences in pupillary diameters were investigated and correlations with age and anterior chamber depth were analyzed. Results For mesopic pup…

Malemedicine.medical_specialtyLightMesopic visionmedicine.medical_treatmentUlls -- AnatomiaAfter cataractGender-related effectPupilCataract03 medical and health sciences0302 clinical medicineEye -- AnatomyMedicineHumansClinical significanceAnterior chamberPupil disordersbusiness.industryPupil sizePupilCataract surgerySurgeryMale patient030221 ophthalmology & optometryCataractes:Ciències de la visió [Àrees temàtiques de la UPC]Femalesense organsbusiness030217 neurology & neurosurgeryAge factorsOptometryPhotopic visionJournal of optometry
researchProduct

Relationship among Corneal Biomechanics, Refractive Error, and Axial Length

2014

Purpose To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickne…

Malemedicine.medical_specialtyRefractive errorIntraocular pressureocular parametersAdolescentgenetic structuresAnterior ChamberVisual AcuityEmmetropiaCorneachildrenOphthalmologyHumansMedicinerefractive errorChildIntraocular PressureDioptreÓpticabusiness.industryBiomechanicsHigh myopiaAxial lengthElastic TissueRefractive Errorsmedicine.diseaseeye diseasesBiomechanical PhenomenaAxial Length EyeOphthalmologyCross-Sectional Studiesagecorneal biomechanical propertiesRegression AnalysisOptometryFemaleMultiple linear regression analysissense organsbusinessTomography Optical CoherenceOptometryOptometry and Vision Science
researchProduct

The methane Raman spectrum from 1200 to 5500 cm(-1): A first step toward temperature diagnostic using methane as a probe molecule in combustion syste…

2005

International audience; We present a study of the spontaneous Raman spectra of (CH4)-C-12 from 1200 to 5500 cm(-1) at various temperatures. This study is of interest from a fundamental as well as from a practical point of view with regards to the temperature diagnostic in hydrocarbon combustion. The present investigation shows that the spontaneous (CH4)-C-12 Raman spectra are very sensitive to temperature and that the complexity of methane spectra is not an obstacle to use methane as a probe molecule in laser-diagnostic techniques. Our study consists in determining the polarisability parameters of methane (CH4)-C-12, unknown at the present time, from spontaneous Raman spectra recorded at pr…

Materials scienceAnalytical chemistry02 engineering and technologyCombustion01 natural sciences7. Clean energyTemperature measurementMethaneSpectral linesymbols.namesakechemistry.chemical_compoundNuclear magnetic resonance(CH4)-C-12Coherent anti-Stokes Raman spectroscopyPhysical and Theoretical ChemistryRamanSpectroscopyPropellant[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]methane010401 analytical chemistrypolarisability021001 nanoscience & nanotechnologyAtomic and Molecular Physics and Optics0104 chemical scienceschemistry13. Climate actionsymbolsCombustion chamber0210 nano-technologyRaman spectroscopytensorial formalismtemperature measurement
researchProduct

The Experimental Validation of a New Thermodynamic Method for TDC Determination

2007

In-cylinder pressure analysis is becoming more and more important both for research and development purpose and for control and diagnosis of internal combustion engines; directly measured by means of a combustion chamber pressure transducers or evaluated by analysing instantaneous engine speed [1,2,3,4], incylinder pressure allows the evaluation of indicated mean effective pressure (IMEP), combustion heat release, combustion phase, friction pressure, etc...It is well known to internal combustion engine researchers that for a right evaluation of these quantities the exact determination of Top Dead Centre (TDC) is of vital importance: a 1° error on TDC determination can lead to evaluation err…

Materials scienceCombustionPressure sensorAutomotive engineeringCylinder (engine)law.inventionDead centreSettore ING-IND/08 - Macchine A FluidoMean effective pressureInternal combustion enginelawSpark-ignition engineMathematical models Diagnostics Spark ignition enginesCombustion chamber
researchProduct

Reduction of low-frequency 1/f noise in Al-AlOx-Al tunnel junctions by thermal annealing

2010

We report that annealing Al-AlOx-Al tunnel junctions in a vacuum chamber at temperature of 400C reduces the characteristic 1/f noise in the junctions, in some cases by an order of magnitude. Both ultra high vacuum and high vacuum fabricated samples demonstrated a significant reduction in the 1/f noise level. Temperature dependence of the noise was studied between 4.2 and 340 Kelvin, with a linear dependence below 100 K, but a faster increase above. The results are consistent with a model where the density of charge trapping two level-systems within the tunneling barrier is reduced by the annealing process.

Materials scienceCondensed Matter - Mesoscale and Nanoscale PhysicsPhysics and Astronomy (miscellaneous)Condensed matter physicsAnnealing (metallurgy)Ultra-high vacuumchemistry.chemical_elementFOS: Physical sciences02 engineering and technologyTrappingLow frequency021001 nanoscience & nanotechnology01 natural scienceschemistryAluminiumCondensed Matter::Superconductivity0103 physical sciencesMesoscale and Nanoscale Physics (cond-mat.mes-hall)Vacuum chamber010306 general physics0210 nano-technologyQuantum tunnellingOrder of magnitude
researchProduct

Design and evaluation of a HDR skin applicator with flattening filter

2008

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…

Materials scienceDosimeterbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomKermaOpticsIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

Numerical Simulation as a Tool for Design Optimization of Two-Phase Swirl Flow Atomizers

2021

This study aims to analyze the hydrodynamics in two-phase swirl flow conical atomizers. The Euler-Euler model was used for the calculations. Numerical simulations were performed to provide information about the fluid velocity distribution and the atomizer’s internal flow. The numerical calculations confirmed the experimental data. This data was found based on the consistency of the spray angles obtained by both methods. Assuming the correctness of the numerical simulations performed, they can be treated as a tool for further analysis of mass and energy exchange along with the atomizer and optimizing the atomizer’s design depending on the requirements. The influence of the swirl chamber geom…

Materials scienceEulerian modelComputer simulationInternal flowFlow (psychology)Phase (waves)Chamber geometrySwirl chamberConical surfaceMechanicsPhysics::Fluid DynamicsFlow velocityConical two-phase atomizersEnergy exchange
researchProduct

New prototypes for the isolation of the anodic chambers in microbial fuel cells

2016

This work has been focused on the assessment of new prototypes of MFC in which a more strict separation of the anode and cathode compartments is looked for, in order to attain strict anaerobic conditions in the anode chamber and hence, avoid lack of efficiency due to the prevalence of non-electrogenic competing microorganisms and to optimize composition of the anolyte and catholyte. A cylinder reactor with an inner chamber with graphite bars acting as anodes and the outer one with a stainless steel tube acting as cathode was used in three different configurations and results obtained during lifetests are compared in terms of electricity production, cathode oxygen consumption and anode COD d…

Materials scienceMicrobial fuel cellMicrobial fuel cell020209 energyGeneral Chemical EngineeringCompartimentos separadosEnergy Engineering and Power Technology02 engineering and technology010501 environmental sciencesDouble chamber01 natural sciencesCámara doblelaw.inventionIsolationlaw0202 electrical engineering electronic engineering information engineeringMiniaturizationChemical Engineering (all)GraphitePrototiposOhmic contact0105 earth and related environmental sciencesAislamientoOrganic ChemistrySeparated compartmentSettore ING-IND/27 - Chimica Industriale E TecnologicaPrototypeCathodeAnodeIngeniería QuímicaElectricity generationFuel TechnologyChemical engineeringDegradation (geology)Pila de combustible microbiana
researchProduct

SiPMs coated with TPB: coating protocol and characterization for NEXT

2012

[EN] Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless \bb decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifte…

Materials sciencePhysics - Instrumentation and DetectorsFOS: Physical scienceschemistry.chemical_elementengineering.materialWavelength shifterTracking (particle physics)7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)XenonSilicon photomultiplierCoating0103 physical sciencesSensitivity (control systems)Visible and IR photons (solid-state)010306 general physicsInstrumentationPhoton detectors for UVMathematical PhysicsScintillationTime projection chamber010308 nuclear & particles physicsbusiness.industryTime projection Chambers (TPC)FísicaDetectorsInstrumentation and Detectors (physics.ins-det)Gas detectorsScintillators scintillation and light emission processes (solid gas and liquid scintillators)Detectors de gasoschemistryParticle tracking detectors (Solid-state detectors)engineeringOptoelectronicsbusiness
researchProduct