Search results for "CHAMBER"

showing 10 items of 359 documents

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

2015

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit …

Physicsbusiness.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineCollimated lightKermaOpticsAbsorbed doseIonizationIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

Forward-central two-particle correlations in p–Pb collisions at sNN=5.02 TeV

2016

Two-particle angular correlations between trigger particles in the forward pseudorapidity range (2.5 < |η| < 4.0) and associated particles in the cen

Physicscongenital hereditary and neonatal diseases and abnormalitiesNuclear and High Energy PhysicsParticle physicsTime projection chamber010308 nuclear & particles physicsAtlas detector01 natural sciencesCharged particleNuclear physicsMuon spectrometerPseudorapidity0103 physical sciencesTransverse momentumRapidityMultiplicity (chemistry)010306 general physicsPhysics Letters B
researchProduct

A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.

2012

In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can …

Physicsmedicine.medical_specialtyRadiological and Ultrasound TechnologyPixelbusiness.industryDetectorRadiosurgerySquare (algebra)OpticsIonizationIonization chambermedicineDosimetryAnisotropyHumansRadiology Nuclear Medicine and imagingMedical physicsRadiotherapy Intensity-ModulatedAnisotropybusinessRadiometryDiodePhysics in medicine and biology
researchProduct

Performance of tracking stations of the underground cosmic-ray detector array EMMA

2018

Abstract The new cosmic-ray experiment EMMA operates at the depth of 75 m (50 GeV cutoff energy for vertical muons; 210 m.w.e.) in the Pyhasalmi mine, Finland. The underground infrastructure consists of a network of eleven stations equipped with multi-layer, position-sensitive detectors. EMMA is designed for cosmic-ray composition studies around the energy range of the knee, i.e., for primary particles with energies between 1 and 10 PeV. In order to yield significant new results EMMA must be able to record data in the full configuration for about three years. The key to the success of the experiment is the performance of its tracking stations. In this paper we describe the layout of EMMA an…

Physics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenatutkimuslaitteetHigh-energy muonsCosmic rayScintillatorTracking (particle physics)01 natural sciencesOpticscosmic rays0103 physical sciencesAngular resolutiondrift chambersUnderground experimentCosmic rays010303 astronomy & astrophysicsImage resolutionPhysicsMuonDrift chambersta114010308 nuclear & particles physicsbusiness.industryDetectorAstronomy and Astrophysicshigh-energy muonsilmaisimetunderground experimentScintillation counterPlastic scintillation detectorsHigh Energy Physics::Experimentbusinesskosminen säteilyMuon trackingmuon trackingplastic scintillation detectorsAstroparticle Physics
researchProduct

Performance study of a 3×1×1 m3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

2021

This work would not have been possible without the support of the Swiss National Science Foundation, Switzerland; CEA and CNRS/IN2P3, France; KEK and the JSPS program, Japan; Ministerio de Ciencia e Innovacion in Spain under grants FPA2016-77347-C2, SEV-2016-0588 and MdM-2015-0509, Comunidad de Madrid, the CERCA program of the Generalitat de Catalunya and the fellowship (LCF/BQ/DI18/11660043) from "La Caixa" Foundation (ID 100010434); the Programme PNCDI III, CERN-RO, under Contract 2/2020, Romania; the U.S. Department of Energy under Grant No. DE-SC0011686. This project has received funding from the European Union's Horizon 2020 Research and Innovation program under Grant Agreement no. 654…

Physics::Instrumentation and DetectorsLibrary scienceargon: gas01 natural sciences7. Clean energyNeutrino detectorArgon gasPolitical scienceParticle tracking detectors0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]media_common.cataloged_instanceNeutrino detectors[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]European union010306 general physicsInstrumentationMathematical Physicsmedia_common010308 nuclear & particles physicsLarge detector systems for particle and astroparticle physicsTime projection Chambers (TPC)time projection chamber: liquid argonParticle tracking detectorTime projection chambercosmic radiationLarge detector systems for particle and astroparticle physicyield: stabilityLiquid argonperformance
researchProduct

The mass-hierarchy and CP-violation discovery reach of the LBNO long-baseline neutrino experiment.

2014

The next generation neutrino observatory proposed by the LBNO collaboration will address fundamental questions in particle and astroparticle physics. The experiment consists of a far detector, in its first stage a 20 kt LAr double phase TPC and a magnetised iron calorimeter, situated at 2300 km from CERN and a near detector based on a high-pressure argon gas TPC. The long baseline provides a unique opportunity to study neutrino flavour oscillations over their 1st and 2nd oscillation maxima exploring the $L/E$ behaviour, and distinguishing effects arising from $\delta_{CP}$ and matter. In this paper we have reevaluated the physics potential of this setup for determining the mass hierarchy (M…

Physics::Instrumentation and Detectorsfar detectorkaukoputket ja teleskoopit7. Clean energyviolation [CP]CP violation; Neutrino Detectors and Telescopes; Oscillation; Nuclear and High Energy PhysicsHigh Energy Physics - Phenomenology (hep-ph)Observatorymass: hierarchy [neutrino]detector [neutrino]QCPhysicsTime projection chamberLarge Hadron ColliderOscillationmagnetization [iron]oscillation [neutrino]High Energy Physics - PhenomenologyCP violationliquid argon [time projection chamber]CP violationNeutrinoParticle physicsNuclear and High Energy PhysicsCERN Lab530 PhysicseducationFOS: Physical sciencesddc:500.2oscillation [flavor]114 Physical sciencesNuclear physicsphase spacenear detectorstatistical analysisiron [calorimeter]Particle Physics - PhenomenologyAstroparticle physicsNeutrino Detectors and Telescopesta114Físicaflavor [neutrino]CP [phase]CERN SPSMODELproposed [observatory]Oscillation13. Climate actionPhase space[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]gas [argon]beam [neutrino]High Energy Physics::ExperimentMATTERneutrino detectorsCP violation.
researchProduct

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

2020

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-r…

Physics::Instrumentation and Detectorsilmaisimettutkimuslaitteetneutriinotlarge detector systems for particle and astroparticle physicsHigh Energy Physics::Experimenttime projection chambers (TPC)noble liquid detectors (scintillation ionization double-phase)hiukkasfysiikka
researchProduct

Performance study of a 3×1×1 m3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

2021

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m3) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views. peerReviewed

Physics::Instrumentation and Detectorsilmaisimettutkimuslaitteetparticle tracking detectorstime projection chambersneutriinotlarge detector systems for particle and astroparticle physicshiukkasfysiikkakosminen säteilyneutrino detectors
researchProduct

Forced Flowering in Mandarin Trees Under Phytotron Conditions

2019

[EN] Phytotron has been widely used to assess the effect of numerous parameters on the development of many species. However, less information is available on how to achieve fast profuse flowering in young fruit trees with this plant growth chamber. This study aimed to outline the design and performance of a fast clear methodology to force flowering in young mandarin trees (cv. Nova and cv. Clemenules) and to analyze the influence of induction intensity on inflorescence type. The combination of a short water stress period with simulated spring conditions (day 13 h, 22 °C, night 11 h, 12 °C) in the phytotron allowed flowers to be obtained only after 68-72 days from the time the experiment beg…

Plant growthCitrusGeneral Chemical EngineeringPhotoperiodWater stressBOTANICAFlowersInflorescence typemedicine.disease_causeMandarin ChineseGeneral Biochemistry Genetics and Molecular BiologyTreesFlower productionCitrus floweringGene Expression Regulation PlantPollenmedicineForced floweringChamber experimentsFloral induction intensityInflorescenceMandarin treesphotoperiodismGeneral Immunology and MicrobiologyGeneral NeurosciencefungiWater stressGrowth chamberfood and beveragesEDAFOLOGIA Y QUIMICA AGRICOLAlanguage.human_languageCold TemperatureEnvironmental sciencesHorticultureIssue 145InflorescencePhytotronGerminationCv. ClemenuleslanguagePhytotronCv. Nova
researchProduct

Sumatriptan Succinate Transdermal Delivery Systems for The Treatment of Migraine

2007

We have successfully obtained sumatriptan transdermal systems with different polymer compositions: methyl cellulose (MC), polyvinyl pyrrolidone (PVP) and a polyvinyl pyrrolidone (PVP)-polyvinyl alcohol (PVA) mixture. The systems contained 1,2-propylenglycol (MC) or sorbitol as a plasticizer (PVP and PVP-PVA), methacrylate copolymer as an adhesive agent, and an occlusive liner. Azone (5%, w/w) was incorporated into all the systems as a percutaneous enhancer. Transdermal systems are thin, transparent and non-adhesive when in a dry state. The permeation of sumatriptan succinate across pig ear skin was studied using the systems prepared. The formulation with MC polymer produced a statistically …

PolymersSwineChemistry PharmaceuticalDrug CompoundingMigraine DisordersSkin AbsorptionPharmaceutical Sciencemacromolecular substancesAbsorption (skin)MethylcellulosePharmacologyAdministration CutaneousPermeabilityDosage formchemistry.chemical_compoundPolymethacrylic AcidsPlasticizersSumatriptan SuccinatemedicineAnimalsSorbitolTechnology PharmaceuticalVasoconstrictor AgentsSkinTransdermalDrug Carriersintegumentary systemSumatriptanChemistrytechnology industry and agriculturePlasticizerPovidoneAzepinesIontophoresisPermeationPropylene GlycolSerotonin Receptor AgonistsKineticsSumatriptanPolyvinyl AlcoholMethyl celluloseDiffusion Chambers CultureTissue AdhesivesNuclear chemistrymedicine.drugJournal of Pharmaceutical Sciences
researchProduct