Search results for "CHAMBER"
showing 10 items of 359 documents
Determination of consensus kQ values for megavoltage photon beams for the update of IAEA TRS-398
2020
The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new beam quality correction factors, kQ, for megavoltage photon beams consistent with developments in radiotherapy dosimetry and technology since the publication of TRS-398 in 2000. Specifically, all values must be based on, or consistent with, the key data of ICRU Report 90. Data sets obtained from Monte Carlo (MC) calculations by advanced users and measurements at primary standards laboratories have been compiled for 23 cylindrical ionization chamb…
First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
2020
The ProtoDUNE-SP detector was constructed and operated on the CERN Neutrino Platform. We thank the CERN management for providing the infrastructure for this experiment and gratefully acknowledge the support of the CERN EP, BE, TE, EN, IT and IPT Departments for NP04/ProtoDUNE-SP. This documentwas prepared by theDUNEcollaboration using the resources of the Fermi National Accelerator Laboratory (Fermilab), a U.S. Department of Energy, Office of Science, HEP User Facility. Fermilab is managed by Fermi Research Alliance, LLC (FRA), acting under Contract No. DE-AC02-07CH11359. This work was supported by CNPq, FAPERJ, FAPEG and FAPESP, Brazil; CFI, IPP and NSERC, Canada; CERN; MSMT, Czech Republi…
Nitrous oxide fluxes from permafrost regions
2020
This dataset is a synthesis of published nitrous oxide (N2O) fluxes from permafrost-affected soils in Arctic, Antarctic, and Alpine permafrost regions. The data includes mean N2O flux rates measured under field (in situ) conditions and in intact plant-soil systems (mesocosms) under near-field conditions. The dataset further includes explanatory environmental parameters such as meteorological data, soil physical-chemical properties, as well as site and experimental information. Data has been synthesized from published studies (see 'Further details'), and in some cases the authors of published studies have been contacted for additional site-level information. The dataset includes studies publ…
Indoor free space optics link under the weak turbulence regime: Measurements and model validation
2015
In this study, the authors present the measurements performed on a free space optics (FSO) communications link using an indoor atmospheric chamber. In particular, the authors have generated several different optical turbulence conditions, demonstrating how even the weak turbulence regime can strongly affect the FSO link performance. The authors have carried out an in-depth analysis of the data collected during the measurements, and calculated the turbulence strength (i.e. scintillation index and Rytov variance) and the important performance metrics (i.e. the Q-factor and bit error rate) to evaluate the FSO link quality. Moreover, the authors have tested, for the first time, an appositely de…
Valoración del manejo de los inhaladores por el personal de enfermería en un hospital de referencia
2008
Objetivo: valorar los conocimientos y adiestramiento del personal de enfermería con el paciente respiratorio en el manejo de la terapia inhalada en distintas salas de hospitalización. Material y métodos: se diseñó un estudio prospectivo con 144 enfermos/as mediante una encuesta individual en la que se solicitó a cada uno de ellos una demostración práctica del manejo del cartucho presurizado con cámara inhalatoria, sin realizar una instrucción teórica previa sobre la técnica. Se revisó la técnica inhalatoria siguiendo los pasos establecidos en la normativa SEPAR. Resultados: participaron 144 de los 177 enfermeros/as (81,4%) que trabajan en las diferentes salas de hospitalización (29 varones,…
An In Vitro Experiment for Postmortem Vascular Permeation. The Passage of Morphine and Morphine Glucuronides Across a Vascular Wall
1997
A venous blood sample taken at autopsy cannot be considered to represent the antemortem blood concentration of a particular substance. Autolytic processes cause disintegration and increasing permeability of the physiological and anatomical barriers such as vascular walls and lead to changes in substance concentrations. In the present study, the experimental design represents an in vitro postmortem simulation of a drug substance crossing a venous wall. The postmortem behavior of morphine, morphine-3- and morphine-6-glucuronide was investigated. A Chien-Valia-diffusion chamber with a patch of inferior vena cava as diffusion barrier was used. For optimal simulation of postmortem events, vein s…
Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review
2016
We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
2019
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…
The design of the DONES lithium target system
2019
Abstract In the framework of the EU fusion roadmap implementing activities, an accelerator-based Li(d,xn) neutron source called DONES (Demo-Oriented early NEutron Source) is being designed within the EUROfusion Work Package Early Neutron Source as an essential irradiation facility for testing candidate materials for DEMO reactor and future fusion power plants. DONES will employ a high speed liquid lithium jet struck by a 125 mA, 40 MeV deuteron beam to generate the intense neutron flux used to irradiate the material samples up to the desired level of displacement damage (˜10 dpa/fpy for iron in 0.3 l) and He production rates (˜10-13 appm He/dpa). In order to rapidly achieve a sound and stab…
First Dark Matter Search Results from the XENON1T Experiment
2017
We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042±12)-kg fiducial mass and in the [5,40] keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93±0.25)×10-4 events/(kg×day×keVee), the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consisten…