Search results for "CIRCUIT"

showing 10 items of 936 documents

A device for PV modules I-V characteristic detection

2013

In this paper an electronic load suitable for the PV module I-V characteristic curve fast detection is presented. This device is designed in agreement with the IEC 82 Techinical Committee Standard since it allows the detection of the characteristic starting from voltage values even lower than 3% of the PV module open circuit voltage. The device main features are short time characteristc detection (2 s), limited ripple of the detected characteristic and low cost. Its validation is carried out by comparing measured data with data from simulations. Simulations are carried out considering two different commercial PV modules and by implementing in Matlab-Simulink environment the four lumped para…

EngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryOpen-circuit voltageRippleElectronic load four lumped parameters model I-V Characteristic Curves Maximum Power PointDevice PropertiesSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciElectronic loadElectronic engineeringIec standardsbusinessVoltageNominal power (photovoltaic)
researchProduct

Obtaining dynamic Norton parameters of a solar panel from manufacturer data

2016

Photovoltaic arrays have been shown to possess significant influence on the dynamic performance of coupled source-converter-load system while its dynamic resistance is the most important parameter, contributing to the overall system dynamics. In this paper, a method of deriving the parameters of linearized photovoltaic equivalent circuit from manufacturer data is proposed. The approach allows predicting the range of dynamic Norton parameters for the expected irradiation and temperature operation conditions thus defining clear bounds required for robust design of the system controller.

EngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryPhotovoltaic systemPhotovoltaic arraysControl engineeringstabilitySystem dynamicsDynamic resistanceRobust designRange (statistics)Solar energy generatorEquivalent circuitbusinessdynamic resistanceSystem controller
researchProduct

Investigation of motor current signature and vibration analysis for diagnosing rotor broken bars in double cage induction motors

2012

This paper investigates the detectability of rotor broken bars in double cage induction motors using current signature and vibration analysis techniques. Double cage induction motors are commonly used for applications where successive loaded starts-up are mandatory. Experimental results were performed under healthy and faulty cases, and for different load conditions using each technique. Rotor broken bars fault detection based on sideband current components may fails due to the presence of inter bar currents that reduce the degree of rotor asymmetry, yielding to a decrease of the magnitude of these spectral components. But inter bar currents produce core vibrations in the axial direction, w…

EngineeringSidebandBars Circuit faults Fault detection Induction motors Rotors Stators Vibrationsbusiness.industryRotor (electric)Squirrel-cage rotorBar (music)MOTOR CURRENT SIGNATURE ANALYSISStructural engineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciVIBRATIONSWound rotor motorFault detection and isolationlaw.inventionVibrationCONDITION MONITORINGDOUBLE CAGE INDUCTION MOTORlawControl theorybusinessInduction motorInternational Symposium on Power Electronics Power Electronics, Electrical Drives, Automation and Motion
researchProduct

Immunity of a Virtual Instrument to conducted electromagnetic disturbances

2004

In the paper the performances of the Virtual Instruments under conducted electromagnetic disturbances are investigated, in order to find out if and how their metrological characteristics change with respect to the ones measured in absence of electromagnetic threats. The analysis is carried out by means of experimental tests, subjecting the AC power port of the systems under test to the conducted disturbances considered by the IEC-61326 standard and following the test procedures prescribed in the IEC-61000-4-series standards. The results show that the tested measurements instruments are sufficiently immune to these disturbances, since no variations of the distinctive parameters have been obs…

EngineeringSignal processingconducted disturbancesVirtual instrumentationVirtual instrumentbusiness.industryTest proceduresElectromagnetic compatibilityPort (circuit theory)AC powerVirtual instrumentControl theoryElectronic engineeringMeasurement uncertaintyEMIbusinessProceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)
researchProduct

A PC-based low cost impedance and gain-phase analyzer

2008

Abstract In this paper, we present a practical and inexpensive impedance/gain-phase analyzer (IGPA), which is very useful in the design of electronic circuits. This instrument allows the Bode diagram of any network or electronic circuit with an input and an output to be obtained, even though this implementation was not previously known. It can also obtain the module and phase diagrams of any impedance separately. The device under test (DUT) is connected to a personal computer (PC) via the parallel port by means of an electronic circuit implemented for this purpose. The results are shown on the screen of the PC and can be accessible for use in any further operation. The instrument operates i…

EngineeringSpectrum analyzerbusiness.industryApplied MathematicsBode plotElectrical engineeringCondensed Matter PhysicsPrecision rectifierPersonal computerElectronic engineeringDevice under testElectrical and Electronic EngineeringbusinessParallel portInstrumentationElectrical impedanceElectronic circuitMeasurement
researchProduct

A disc-type motor with co-axial flux in the stator; - influence of magnetic circuit parameters on the torque

2002

This paper presents a three-dimensional analysis of the magnetic field distribution for a three-phase, disc-type, permanent-magnet, brushless DC motor with co-axial flux in the stator. Calculations are carried out using the 3-D finite element method (FEM). The electromagnetic torque is determined from the Maxwell stress tensor. For comparison, various dimensions of permanent magnets, pole shoes and air gap are analysed. It is shown that the ripple-cogging torque can be effectively reduced by an appropriate permanent magnet width and air-gap length. The simulation results are in good agreement with experimental data obtained from the prototype motor.

EngineeringStatorbusiness.industryApplied MathematicsElectrical engineeringMaxwell stress tensorMechanicsAC motorlaw.inventionMagnetic circuitDirect torque controllawMagnetElectrical and Electronic EngineeringbusinessSynchronous motorInduction motorElectrical Engineering (Archiv fur Elektrotechnik)
researchProduct

Thermo acoustic - MHD electrical Generator

2011

Abstract The thermo-acoustic generators offer a unique means of converting thermal energy into mechanical energy without any moving parts and without fluid circulation. They are comparable to the Stirling engine with the advantage of much greater simplicity. They are therefore natural candidates for special uses where interventions are limited. The problem to solve is transforming the mechanical energy into electrical energy. MHD generators offer excellent opportunities in this area, particularly by using the mechanisms of induction. The work concerns the combination of a thermo-acoustic generator with an induction generator of a new concept for obtaining electric current with adjustable vo…

EngineeringStirling enginebusiness.industrygeneratorThermo-acousticInduction generatorElectric generatorMechanical engineeringlaw.inventionGenerator (circuit theory)Electricity generationEnergy(all)lawElectricityelectricitybusinessmagnetohydrodynamicsThermal energyMechanical energyEnergy Procedia
researchProduct

Task scheduling control of BGA solder joint process in flexible manufacturing system

2006

This paper describes an open loop control method of the solder joint process in a rework station for faulty printed circuit board (PCBs) containing electronic components in packages ball grid arrays (BGAs). In particular, a mathematical model describing the solder joint process is, first of all, obtained. Then, the desired thermal profile of the junctions BGA-PCB is determined according to the physical constraints of the rework station framework. The control parameters corresponding to the above desired thermal profile are identified using the above mathematical model. Finally, the open loop control algorithm is implemented on the supervisor interface of the rework station in order to carri…

EngineeringSupervisorbusiness.industryReworkFlexible manufacturing systemMechanical engineeringBall Grid Arrays (BGA)GridControl parameterOpen loop control algorithmsPrinted circuit boardSettore ING-INF/04 - AutomaticaEmbedded systemBall grid arrayvisual_artSolderingElectronic componentvisual_art.visual_art_mediumbusiness
researchProduct

Soft switched interleaved boost converters used as high-power battery discharge regulator for space power systems

2004

In the following years the telecommunication satellites will have a much greater power demand than nowadays. One reason for this is that the geostationary orbit required by this kind of satellites is becoming too crowded. Probably power levels of l0 kW to l00 kW will be the standard and with life duration of 25 years. It is not possible to keep 0.5 kW modules with more than 100 in parallel and therefore higher power modules (5 kW) must be used. A higher bus voltage seems also necessary and keeping a safety limit of 150 V, any voltage below it and above 100 V could meet the needs. In this paper we will propose a topology that fits the application: two soft switched interleaved boost converte…

EngineeringSwitched-mode power supplybusiness.industryLimit (music)Electrical engineeringElectronic engineeringGeostationary orbitTopology (electrical circuits)Power factorConvertersbusinessPower controlPower (physics)Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04.
researchProduct

Controlled Fault-Tolerant Power Converters for Power Quality Enhancement

2013

Power quality depends generally on the interaction of electrical power with electrical equipments. If electrical equipments operate correctly and reliably without being damaged or stressed, a suitable level of power quality is assured. On the other hand, if the electrical equipment malfunctions, is unreliable, or is damaged during normal usage, power quality is poor and probably the economical loss could be important like the technical one. In the scenario of the Distributed Generation, power quality issues will be moreover important because an higher dissemination of power conditioning equipment will be requested and this obviously increases the sources of vulnerability of the electrical s…

EngineeringSwitched-mode power supplypower supply qualitypower system controlSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciPower budgetpower quality enhancementTopologyMaximum power point trackingfault tolerant power converterfuel cellpower supplieElectric power systemMathematical modelpower convertorElectronic engineeringcontrolled fault-tolerant power converterPower-flow studyCircuit faulthybrid power systemdistributed generationFault tolerant systembusiness.industryFault toleranceReliability engineeringPower ratingBase load power plantPower qualityModeling and Simulationpower conditioning equipmentElectric powerVectorbusinessfault tolerance;power convertors;power supply quality;controlled fault-tolerant power converters;distributed generation;fault tolerant power converters;power conditioning equipment;power quality enhancement;Circuit faults;Fault tolerance;Fault tolerant systems;Mathematical model;Power quality;Topology;Vectors;fuel cells;hybrid power systems;power supplies;power system control
researchProduct