Search results for "CLEAR"
showing 10 items of 27042 documents
Rac1 and PAK1 are upstream of IKK-ε and TBK-1 in the viral activation of interferon regulatory factor-3
2004
The anti-viral type I interferon (IFN) response is initiated by the immediate induction of IFN beta, which is mainly controlled by the IFN-regulatory factor-3 (IRF-3). The signaling pathways mediating viral IRF-3 activation are only poorly defined. We show that the Rho GTPase Rac1 is activated upon virus infection and controls IRF-3 phosphorylation and activity. Inhibition of Rac1 leads to reduced IFN beta promoter activity and to enhanced virus production. As a downstream mediator of Rac signaling towards IRF-3, we have identified the kinase p21-activated kinase (PAK1). Furthermore, both Rac1 and PAK1 regulate the recently described IRF-3 activators, I kappa B kinase- and TANK-binding kina…
High Bias Voltage CZT Detectors for High-flux Measurements
2017
In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…
Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses
2018
In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…
THERP and HEART integrated methodology for human error assessment
2014
Medical errors are one of the leading causes of death and injury in radiation therapy administration as reported in the literature. This point out an overall deficiency in management allowing patient treatment in the absence of suitable quality assurance processes. Clinical records of major accidental exposure events in radiotherapy show that there is a combination of factors contributing to the accident such as deficient staff training, lack of independent checks, lack of quality control procedures, and absence of overall supervision. Another finding is that training generally addresses only normal situations and does not prepare radiotherapy staff for unusual situations, resulting in a la…
A GEM-TPC in twin configuration for the Super-FRS tracking of heavy ions at FAIR
2018
The GEM-TPC [1] described herein will be part of the standard beam-diagnostics equipment of the Super-FRS [2] . This chamber will provide tracking information for particle identification at rates up to 1 MHz on an event-by-event basis. The key requirements of operation for these chambers are: close to 100% tracking efficiency under conditions of high counting rate, spatial resolution below 1 mm and a superb large dynamic range covering projectiles from Z=1 up to Z=92. The current prototype consists of two GEM-TPCs inside a single vessel, which are operating independently and have electrical drift fields in opposite directions. The twin configuration is done by flipping one of the GEM-TPCs o…
Transport and extraction of radioactive ions stopped in superfluid helium
2003
A new approach to convert a high energy beam to a low energy one, which is essential for the next generation radioactive ion beam facilities, has been proposed and tested at Jyvaskyla, Finland. An open Ra-223 alpha-decay-recoil source has been used to produce radioactive ions in superfluid helium. The alpha spectra demonstrate that the recoiling Rn-219 ions have been extracted out of liquid helium. This first observation of the extraction of heavy positive ions across the superfluid helium surface was possible thanks to the high sensitivity of radioactivity detection. An efficiency of 36% was obtained for the ion extraction out of liquid helium. (C) 2003 Elsevier Science B.V. All rights res…
Identification of the Jπ = 1− state in 218Ra populated via α decay of 222Th
2016
The α decay of 222Th populating the low-lying J π = 3− state, and also a proposed 1− state, in 218Ra has been observed. The observations suggest an excitation energy of 853 keV for the 1− state, which is 60 keV above the 3− state. The hindrance factors of these α decays give a possible boundary to the region of ground-state octupole deformation in the light-actinide nuclei. The relative positions of the J π = 1− and 3− states suggest they are produced by an octupole-vibrational mechanism, as opposed to α clustering or rotations of a reflection-asymmetric octupole-deformed shape. peerReviewed
Prevalencia y factores de desgaste profesional en radiólogos durante la pandemia COVID-19
2022
Antecedentes: La epidemia por coronavirus 2019 (COVID-19) se ha extendido por todo el mundo desde principios de 2020, sometiendo a los profesionales sanitarios a una sobrecarga laboral ya un mayor nivel de estrés físico y emocional. Objetivos: El objetivo de este estudio es determinar la prevalencia de desgaste profesional y sus posibles factores asociados en los radiólogos españoles durante la COVID-19, y su comparación con la situación previa a la pandemia. Métodos: Estudio observacional realizado entre los meses de abril y agosto de 2020 (durante la pandemia) mediante una encuesta en línea. Se obtuvieron un total de 150 respuestas. Se recopiló y comparó la información demográfica y labor…
First observation and study of the K± → π±π0e+e− decay
2018
The NA48/2 experiment at CERN reports the first observation of the K-+/- -> pi(+/-)pi(0)e(+)e(-) decay from an exposure of 1.7 x 10(11) charged kaon decays recorded in 2003-2004. A sample of 4919 candidates with 4.9% background contamination allows the determination of the branching ratio in the full kinematic region, BR(K-+/- -> pi(+/-)pi(0)e(+)e(-)) = (4.24 +/- 0.14) x 10(-6). The study of the kinematic space shows evidence for a structure dependent contribution in agreement with predictions based on chiral perturbation theory. Several P- and CP-violating asymmetries are also evaluated.
Rare beta decays and the spectrum-shape method
2017
This is a thesis consisting of seven publications and an introductory part on theoretical studies on rare single beta decays. Firstly, the theoretical framework is applied to the computation of partial half-lives for few selected cases of rare single beta-decay transitions. This includes the study on a possible ultra-low-Q-value decay branch of 115Cd as well as the highly forbidden beta decays of 48Ca and 50V. The double magic 48Ca is one of the few experimentally verified nuclei that decay via the two-neutrino mode of double beta decay. A theoretical study on the single beta-decay branches was used to inspect the competition between the single and double beta-decay channels. In the case of…