Search results for "COMPOSITE"
showing 10 items of 4584 documents
New method to determine the true transmissibilities and permeabilities of oxygen in hydrogel membranes
1999
In the present paper, an electrochemical method to obtain the true transmissibilities and permeabilities of hydrogels to oxygen is proposed. The method involves the measurement of the electric current arising from the flow of oxygen through a potentiostat cell integrated by a top water layer, the hydrogel membrane, and a thin water layer between the membrane and the cathode, where the oxygen is reduced. Varying the thickness of the top water layer, the true permeation characteristics of the hydrogels are obtained. A parallel study was carried out in which the transmissibilities and permeation coefficients were obtained from the variation of the steady state current with the thickness of the…
A new selective fluorogenic probe for trivalent cations.
2012
[EN] A new selective chromo-fluorogenic probe for Fe 3+, Cr 3+ and Al 3+ is reported. Detection limits are in the ¿M range and the fluorogenic sensing ability could be observed by the naked eye when illuminated with UV-light. No response is observed with divalent cations. © 2012 The Royal Society of Chemistry.
Strong circularly polarized luminescence of an octahedral chromium(iii) complex
2019
The chiral spin-flip luminophore [Cr(ddpd)2]3+ can be resolved into enantiopure material by chiral HPLC. The corresponding enantiomers show very high luminescence dissymmetry factors of up to ∣glum ∣≈ 0.093 in circularly polarized luminescence (CPL) measurements for the "ruby-like" phosphorescence transition 2E/2T1 → 4A2 in the near-IR region around λ ≈ 775 nm.
Specific interaction of citrate with bis(fluorophoric) bibrachial lariat aza-crown in comparison with the other components of the Krebs cycle
2006
Clares Garcia, M. Paz, M.Paz.Clares@uv.es ; Garcia-España Monsonis, Enrique, Enrique.Garcia-Es@uv.es ; Soriano Soto, Concepcion, Concepcion.Soriano@uv.es ; Tejero Toquero, Roberto, Roberto.Tejero@uv.es
Use of Ultrasound in Reconditioning by Welding of Tools Used in the Process of Regenerating Rubber
2018
Addressing the problem of reconditioning large parts is of particular importance, due to their value and to the fact that the technologies for their reconditioning are very complex. The tools used to refine regenerated rubber which measure 660 mm in diameter and 2130 mm in length suffer from a rather fast dimensional wear. Within this research, the authors looked for a welding reconditioning procedure that would allow a very good adhesion between the deposited material layer and the base material. In this regard, the MAG (Metal Active Gas) welding process was used, but the ultrasonic activation of the welding process was also considered. Thus, the wire used for welding was activated conside…
The durability of basalt fibres reinforced polymer (BFRP) panels for cladding
2015
The study focuses on two basalt composite laminate panels for cladding, produced by means of vacuum bagging technique. In particular, unidirectional and random basalt fabrics, with different areal weights, using epoxy resin as matrix, were used. According to the ISO 15686 methodology for the evaluation of durability, samples were subjected to cycles of artificial aging in climatic chamber and outdoor exposure, carrying out mechanical (i.e. quasi-static and dynamic) and calorimetric tests. The results show the effectiveness over time of produced basalt composite laminates and the initial increase of the mechanical performances after the first steps of accelerated aging.
Contributions regarding increasing reliability of beer industry installations using weld cladding in ultrasonic field
2016
Paper presents a new technology for availability increasing of different installation parts used in beer industry - ultrasonic activation of metal deposition by welding. The dilution phenomenon is studied linked on its influence upon material technological and functional properties in the three distinct zones of resulted couple (filler material, influenced thermal zone, base material). Experimental results performed on unidirectional valve are presented regarding variation of chemical composition concentration and dilution variation in three zones influenced by ultrasonic wave.
Modelling the influence of nanoparticles in the phase behaviour of an epoxy/polystyrene mixture
2007
Abstract The cloud point temperatures of four series of epoxy/polystyrene blends have been experimentally determined as a function of polymer mass and system composition. The phase diagrams show an UCST behaviour, increasing incompatibility as the molar mass increases. The Flory–Huggins theory with a concentration-dependent interaction parameter has been developed to study the compatibility of two polymers in presence of spherical nanoparticles. This theory has been first compared with the experimental cloud point curve in absence of nanoparticles, and secondly it has been used to predict the thermodynamic behaviour in presence of different volume fraction of nanoparticles. Nanoparticles co…
Complex miscibility behaviour for polymer blends in flow
1995
Abstract Experimental observations of the effect of shear flow on the miscibility of binary polymer blends are compared to calculations based on a generalized Gibbs energy of mixing Gγ˙. This mixing free energy characterizes the steady state established at shear rateγ˙, as the sum of G z , the equilibrium Gibbs energy and E s , the energy the system stores while flowing.
Preparation, characterization and hydrolytic degradation of PLA/PCL co-mingled nanofibrous mats prepared via dual-jet electrospinning
2017
Abstract PLA/PCL co-mingled nanofibrous mats were prepared via multi-jet electrospinning. The concentration of PLA and PCL in the co-mingled mats were controlled by changing the flow rate of the two polymer solutions. The amount of PLA and PCL in the co-mingled nanofibrous mats was monitored by UV–Vis measurements through a colored dye added to PLA and by FTIR-ATR analysis. Morphology and mechanical properties of the nanofibrous mats were respectively examined by scanning electron microscopy (SEM) and tensile tests. Water contact angles measurements were also carried out in order to investigate the wettability of the materials. Finally, the hydrolytic degradation of the mats in buffer solut…