Airway remodelling assessed by sputum and high resolution computed tomography in asthma and COPD
2004
It is not known whether sputum elastase, metalloproteinase (MMP)-9 and tissue-inhibitor metalloproteinase (TIMP)-1 are related to structural changes of the airways, as assessed by high-resolution computed tomography (HRCT) scan. The relationships between these markers and the magnitude of structural changes of the airways in asthma and chronic obstructive pulmonary disease (COPD) were assessed. Induced sputum and HRCT scan were performed in 30 asthmatics (14 mild and 16 severe) and in 12 patients with COPD. A greater extent of HRCT scan abnormalities was found in COPD than in severe and mild asthmatics. HRCT scan abnormalities correlated with the degree of airway obstruction in COPD and in …
Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.
2014
To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population.This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest–abdomen–pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDIvol) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure.The 75th percentiles of CTDIvol (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm…
Complete written/oral information about dose exposure in CT: is it really useful to guarantee the patients' awareness about radiation risks?
2018
Aims and objectives: According to the European directive 2013/59/Euratom, starting from February 2018, the information relating to patient exposure will be part of computed tomography (CT) reports, but the impact of this information on patients has not been deeply evaluated. Aim of our study was to evaluate patients’ perception of radiation exposure related to routine CT and their understanding after communication of their dose exposure. Materials and methods: A survey, investigating patient’s knowledge of radiation dose, was given to all adult patients (> 18 years) undergoing a CT examination both before and after CT scan. The first survey was the same for all patients. After CT scan, a se…
Comparison of CT and magnetic resonance mDIXON-Quant sequence in the diagnosis of mild hepatic steatosis
2018
Objective: To determine the diagnostic performance of CT in the assessment of mild hepatic steatosis by comparison with MR mDIXON-Quant as a reference standard, and to explore their clinical applications. Methods: In this prospective study 169 volunteers were included. Each subject underwent CT and MR mDIX-ON-Quant examinations. Hepatic steatosis evaluations were performed via liver attenuation alone (CT L), liver to spleen attenuation ratio (CT L/S), difference between liver and spleen attenuation (CT L-S), and MR mDIX-ON-Quant imaging. The effectiveness of CT L, CT L/S, and CT L-S in diagnosing hepatic steatosis severity of ≥5%, ≥10%, and ≥15% was compared, using mDIX-ON-Quant results as …
A rare clinical entity: stump appendicitis. Case report and complete review of literature.
2019
BACKGROUND: Stump appendicitis is a rare delayed complication post-appendectomy and it represents a diagnostic problem as clinicians are often not very familiar with this pathology. MATERIALS AND METHODS: One case of stump appendicitis has been reported in a 54 year old woman, whose acute phase was conservatively treated in our Department. A review of Medline literature was also carried out, from 1945 to 2015, showing 111 cases of stump appendicitis. RESULTS: Stump appendicitis has been reported after either open or laparoscopic appendectomy, in a range between days to several years from the first procedure. Nowadays, it is not considered yet as a possible differential diagnosis in patients…
Image-Guided Transcranial Doppler Ultrasound for Monitoring Posthemorrhagic Vasospasms of Infratentorial Arteries: A Feasibility Study
2019
Background A considerable number of patients with subarachnoid hemorrhage (SAH) develop vasospasms of the infratentorial arteries. Transcranial Doppler sonography (TCD) is used to screen for vasospasm. In this study, we used a technical modification that combines TCD with an image guidance device that the operator can use to navigate to the ultrasonic window and to predefined intracranial vascular targets. Our aim was to analyze the feasibility, spatial precision, and spatial reproducibility of serial image-guided TCD of infratentorial and—for comparison—supratentorial arteries in the clinical setting of monitoring for vasospasm after SAH. Methods The study included 10 SAH patients, who eac…
Stone-Free Rate after Treating Kidney Stones Exceeding 10 mm via Flexible Ureteroscopy: Can Endoscopic Assessment Replace Low-Dose Computed Tomograph…
2019
<b><i>Introduction:</i></b> It is unclear whether endoscopic assessment of the stone-free rate after flexible ureteroscopy (fURS) is as effective as assessment with low-dose computed tomography (CT) scan. <b><i>Methods:</i></b> Prospective documentation of patients with kidney stones &#x3e; 10 mm diameter from 2 different centers (Freiburg, Regensburg), who underwent fURS and were declared to be endoscopically completely stone-free. Low-dose CT control performed 4–8 weeks postoperatively. <b><i>Results/Conclusion:</i></b> Thirty-eight patients were treated between October 2015 and August 2016 (12 F, 26 M). Average a…
Pharmacological stress, rest perfusion and delayed enhancement cardiac magnetic resonance identifies very early cardiac involvement in systemic scler…
2017
Objective To evaluate occult cardiac involvement in asymptomatic systemic sclerosis (SSc) patients by pharmacological stress, rest perfusion and delayed enhancement cardiac magnetic resonance (CMR), for a very early identification of patients at higher risk of cardiac-related mortality. Methods Sixteen consecutive patients with definite SSc, fulfilling the American College of Rheumatology/European League Against Rheumatism 2013 classification criteria in less than 1 year from the onset of Raynaud's phenomenon, underwent pharmacological stress, rest perfusion and delayed enhancement CMR. At enrollment, no patient showed signs and/or symptoms suggestive for cardiac involvement. No patient sho…
Characterisation of focal liver lesions undetermined at grey-scale US: contrast-enhanced US versus 64-row MDCT and MRI with liver-specific contrast a…
2010
The aim of this study was to assess the role of contrast-enhanced ultrasonography (CEUS) in the characterisation of focal liver lesions in comparison with multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) with liver-specific contrast agent.One hundred and eighty-seven focal liver lesions, 91 malignant and 96 benign (mean size 3.2 cm) - proved by biopsy (n=12), histology (n=4), MDCT (n=108), MRI (n=44) MDCT/MRI (n=19) - in 159 patients were studied by CEUS. Two expert radiologists consensually evaluated the contrast-enhancement patterns at CEUS. For each lesion, they assessed: (a) nature (benign, malignant, not assessable), (b) specific diagnosis and (c) need for …
Pulmonary emphysema in cystic fibrosis detected by densitometry on chest multidetector computed tomography.
2013
BackgroundHistopathological studies on lung specimens from patients with cystic fibrosis (CF) and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT) of the chest for non-invasive characterization and quantification of emphysema in CF.MethodsVolumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years) and 21 non-CF controls (median age 30.4 years; range 4-68 years), and subj…