6533b851fe1ef96bd12aa1d7

RESEARCH PRODUCT

Image-Guided Transcranial Doppler Ultrasound for Monitoring Posthemorrhagic Vasospasms of Infratentorial Arteries: A Feasibility Study

Alf GieseMaximilian SteinManfred BerresCarolin BrockmannSven R. KantelhardtTobias PantelAxel Neulen

subject

AdultMaleSubarachnoid hemorrhageComputed Tomography AngiographyUltrasonography Doppler TranscranialCerebral arteriesBrain Ischemia03 medical and health sciencessymbols.namesake0302 clinical medicinemedicineHumansVasospasm Intracranialcardiovascular diseasesImage guidanceVertebral ArteryAgedComputed tomography angiographyReproducibilitymedicine.diagnostic_testbusiness.industryReproducibility of ResultsVasospasmCerebral ArteriesMiddle AgedSubarachnoid Hemorrhagemedicine.diseaseCerebral AngiographyTranscranial DopplerBasilar Artery030220 oncology & carcinogenesiscardiovascular systemsymbolsFeasibility StudiesFemaleSurgeryNeurology (clinical)businessNuclear medicineDoppler effectBlood Flow Velocity030217 neurology & neurosurgery

description

Background A considerable number of patients with subarachnoid hemorrhage (SAH) develop vasospasms of the infratentorial arteries. Transcranial Doppler sonography (TCD) is used to screen for vasospasm. In this study, we used a technical modification that combines TCD with an image guidance device that the operator can use to navigate to the ultrasonic window and to predefined intracranial vascular targets. Our aim was to analyze the feasibility, spatial precision, and spatial reproducibility of serial image-guided TCD of infratentorial and—for comparison—supratentorial arteries in the clinical setting of monitoring for vasospasm after SAH. Methods The study included 10 SAH patients, who each received 5 serial image-guided TCD examinations. Using computed tomography angiography data, trajectories to the infratentorial and supratentorial cerebral arteries were planned and loaded into an image guidance device tracking the Doppler probe. As a measure of spatial precision and spatial reproducibility, we analyzed the distances between the positions of preplanned vascular targets and optimal Doppler signals. Results The mean distance between preplanned and optimal target points was 4.8 ± 2.1 mm (first exam), indicating high spatial precision. The spatial precision decreased with increasing depth of the vascular target. In all patients, image-guided TCD detected all predefined supratentorial and infratentorial vascular segments. There were no significant changes in spatial precision in serial exams, indicating high reproducibility. Conclusions Image-guided TCD is feasible for supratentorial and infratentorial arteries. It shows high spatial precision and reproducibility. This study provides a basis for future clinical studies on image-guided TCD for post-SAH vasospasm screening.

https://doi.org/10.1016/j.wneu.2019.10.144