Search results for "COMPUTED TOMOGRAPHY"

showing 10 items of 713 documents

Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

2019

Purpose Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to develop a marker-free iterative motion correction algorithm that works on the projection images and is suitable for local tomography. Methods We present an iterative motion correction algorithm that allows the patient's motion to be detected and taken into account during reconstruction. The core of our method is a fast GPU-accelerated three-dimensional reconstruction algorith…

Image qualitybusiness.industryComputer scienceMovementMotion (geometry)Reconstruction algorithmGeneral MedicineFunction (mathematics)Cone-Beam Computed Tomography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineImaging Three-Dimensional030220 oncology & carcinogenesisDentistryHumansComputer visionTomographyArtificial intelligenceProjection (set theory)businessVolume (compression)Medical physicsReferences
researchProduct

Analysis of the physicochemical properties, cytotoxicity and volumetric changes of AH Plus, MTA Fillapex and TotalFill BC Sealer

2020

Background To evaluate the physicochemical properties and cytotoxicity of AH Plus, MTA Fillapex and TotalFill BC Sealer. Volumetric changes were also evaluating using micro-computed tomography (micro-CT). Material and Methods Radiopacity and flow were evaluated in accordance with the ISO 6876, while setting time was evaluated in accordance with the ASTM- C266-08 specifications. The release of Ca2+ ions and pH were measured with spectrophotometer and pH meter, respectively, after different time intervals (1h, 3h, 24h, 72h, 168h, and 360h). Cytotoxicity was evaluated by MTT reduction assay to check 3T3 cells viability at 24, 48 and 72 hours. Volumetric change was evaluated by micro-CT, by usi…

Ion releaseChemistryMicro computed tomographyRoot canalRadiodensityResearch030209 endocrinology & metabolism030206 dentistryRADIOPACIDADE:CIENCIAS MÉDICAS [UNESCO]pH meterOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureDistilled waterMTA-FillapexUNESCO::CIENCIAS MÉDICASmedicineCytotoxicityGeneral DentistryNuclear chemistryJournal of Clinical and Experimental Dentistry
researchProduct

Condylar distances in hypermobile temporomandibular joints of patients with excessive mouth openings by using computed tomography

2014

Objectives: hypermobility in Temporomandibular joint (TMJ) can manifest higher range of motions in mandible. The aim of this study was to compare the position and distances of the head of condyle to glenoid fossa in TMJs of healthy individuals and patients with mild, moderate and severe TMJ hypermobility. Material and Methods: In this clinical study, 69 patients (between the ages of 22 to 42) with manifestation of joint hypermobility were included and Computed tomography were administered for both TMJs. The patients were divided into three groups based on their maximum mouth opening (MMO): (A) with MMO of 50-55 mm; (B) with MMO between 55 to 65 mm; and (C) with MMO >65 mm. Also, 15 healthy …

Joint hypermobilitymedicine.medical_specialtyFossaPost hocOdontologíaComputed tomographyCondylestomatognathic systemMedicineGeneral DentistryOrthodonticsbiologymedicine.diagnostic_testbusiness.industryResearchMandible:CIENCIAS MÉDICAS [UNESCO]biology.organism_classificationClosed mouthmedicine.diseaseCiencias de la saludSurgeryTemporomandibular jointmedicine.anatomical_structureUNESCO::CIENCIAS MÉDICASOral SurgerybusinessJournal of Clinical and Experimental Dentistry
researchProduct

Kontrastmittel-Kurzinfusion oder -Bolusinjektion bei der i.v. Urographie

1993

The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the …

Kidneymedicine.diagnostic_testbusiness.industryComputed tomographyCollection systemContrast mediumBolus (medicine)medicine.anatomical_structureContrast injectionmedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicinePyelogramBolus injectionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Lung CT Image Registration through Landmark-constrained Learning with Convolutional Neural Network

2020

Accurate registration of lung computed tomography (CT) image is a significant task in thorax image analysis. Recently deep learning-based medical image registration methods develop fast and achieve promising performance on accuracy and speed. However, most of them learned the deformation field through intensity similarity but ignored the importance of aligning anatomical landmarks (e.g., the branch points of airway and vessels). Accurate alignment of anatomical landmarks is essential for obtaining anatomically correct registration. In this work, we propose landmark constrained learning with a convolutional neural network (CNN) for lung CT registration. Experimental results of 40 lung 3D CT …

LandmarkSimilarity (geometry)medicine.diagnostic_testArtificial neural networkComputer sciencebusiness.industryDeep learningImage registrationComputed tomographyThoraxConvolutional neural network030218 nuclear medicine & medical imagingEuclidean distance03 medical and health sciences0302 clinical medicinemedicineComputer visionNeural Networks ComputerTomographyArtificial intelligenceTomography X-Ray ComputedbusinessLung030217 neurology & neurosurgery2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
researchProduct

Performance of morphologic criteria for the diagnosis of cirrhosis in patients with non-alcoholic steatohepatitis compared to other etiologies of chr…

2020

Purpose To compare the diagnostic performance of morphologic criteria for detection of cirrhosis in patients with alcoholic liver disease (ALD), hepatitis C (HCV), and non-alcoholic steatohepatitis (NASH). Methods One hundred patients (53 male) with different etiologies of chronic liver disease (NASH,n = 41; HCV,n = 39; and ALD,n = 20) and with different degrees of fibrosis on histopathologic examination (74 with cirrhosis) were retrospectively evaluated. Four readers (R1: fellowship-trained abdominal radiologist, R2: community attending radiologist, R3: senior radiology resident/research fellow, R4: junior radiology resident) analyzed the contrast-enhanced CTs for presence of commonly acce…

Liver CirrhosisMalemedicine.medical_specialtyAlcoholic liver diseaseCirrhosisUrologyChronic liver diseaseGastroenterology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineNon-alcoholic fatty liver diseases (NAFLD)Non-alcoholic Fatty Liver DiseaseInternal medicineAscitesmedicineHumansRadiology Nuclear Medicine and imagingLiver Diseases AlcoholicComputed tomographyRetrospective StudiesRadiological and Ultrasound Technologybusiness.industryGastroenterologyHepatitis CHepatologymedicine.diseaseCirrhosis030220 oncology & carcinogenesisPortal hypertensionSteatohepatitismedicine.symptombusinessNon-alcoholic steatohepatiti
researchProduct

Uncommon imaging evolutions of focal liver lesions in cirrhosis.

2019

Objective: The purpose of this article is to describe and illustrate uncommon imaging evolutions of benign (i.e., cyst, hemangioma, focal nodular hyperplasia-like nodules, and hepatic angiomyolipoma) and malignant (i.e., HCC and non HCC malignancies) lesions in a cirrhotic liver. The content highlights relevant pathogenesis and imaging clues for proper differential diagnosis. Revision of prior imaging and knowledge of these scenarios may help the abdominal radiologist to reach a noninvasive diagnosis and direct the patient to the most appropriate clinical management. Conclusion: Uncommon imaging evolutions of focal liver lesions in cirrhosis may represent a challenge for the abdominal radio…

Liver CirrhosisMalemedicine.medical_specialtyCirrhosisHepatic AngiomyolipomaHepatocellular carcinomaUrologyLiver neoplasm030218 nuclear medicine & medical imagingLiver cirrhosiHemangioma03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingCystComputed tomographyAgedAged 80 and overRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryCystsLiver DiseasesLiver NeoplasmsGastroenterologyMagnetic resonance imagingHepatologyMiddle Agedmedicine.diseaseMagnetic Resonance ImagingLiverFocal Nodular Hyperplasia030220 oncology & carcinogenesisHepatocellular carcinomaFemaleRadiologyDifferential diagnosisbusinessTomography X-Ray ComputedAbdominal radiology (New York)
researchProduct

Computed tomographic imaging of hepatocellular carcinoma

2004

The ability of x-ray computed tomography (CT) to detect and characterize liver lesions has been one of the most studied issues in radiology during the past 20 years. Technological advances, combined with increased knowledge about the pathophysiological characteristics of these tumors, have dramatically increased the ability to detect and characterize large hepatocellular carcinomas (HCCs). Nonetheless, detection and characterization of early and small HCC lesions remains a difficult task. We review the imaging appearances of HCC on CT and discuss the sensitivity and specificity of computed tomographic imaging in screening patients with cirrhosis for HCC.

Liver Cirrhosismedicine.medical_specialtyCarcinoma HepatocellularCirrhosisHepatologymedicine.diagnostic_testbusiness.industryLiver NeoplasmsGastroenterologyComputed tomographymedicine.diseaseSensitivity and Specificitydigestive system diseasesComputed tomographicX ray computedHepatocellular carcinomaCarcinomamedicineHumansTomographyRadiologyTomography X-Ray ComputedbusinessneoplasmsGastroenterology
researchProduct

MULTI-SCALE ANALYSIS OF LUNG COMPUTED TOMOGRAPHY IMAGES

2007

A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

LungReceiver operating characteristicmedicine.diagnostic_testComputer sciencebusiness.industryFOS: Physical sciencesPattern recognitionComputed tomographyCADFilter (signal processing)Physics - Medical PhysicsScale analysis (statistics)Reduction (complexity)Computerized Tomography (CT) and Computed Radiography (CR ).medicine.anatomical_structuremedicineSegmentationMedical Physics (physics.med-ph)Artificial intelligencebusinessInstrumentationMedical-image reconstruction methods and algorithms computer-aided soMathematical Physics
researchProduct

Computertomographie der Atelektase

1987

After breathing pure oxygen, total atelectasis of one lung was produced in ten dogs; its development and regression was followed by CT and by conventional radiology. 30 seconds after cessation of ventilation, it was possible to show a rise in CT density of the atelectatic lung from -764 +/- 32 HU to -739 +/- 49 HU. The average time from the cessation of ventilation to total atelectasis averaged 5.5 +/- 1.1 minutes. The earliest sign on conventional radiographs was often seen after 30 seconds and usually after 60 seconds and consisted of mediastinal displacement. Extensive atelectasis regressed in only one out of six animals within one hour after resuming ventilation. The experimental method…

Lungmedicine.diagnostic_testConventional radiologybusiness.industryContext (language use)AtelectasisComputed tomographyMEDIASTINAL DISPLACEMENTmedicine.diseasemedicine.anatomical_structureBreathingMedicineRadiology Nuclear Medicine and imagingExperimental methodsNuclear medicinebusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct