Search results for "CONSTRUCTION"
showing 10 items of 2670 documents
A Demonstrator for a new Axial PET Concept
2008
In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…
Resolution improvements in integral microscopy with Fourier plane recording
2016
Abstract: Integral microscopes (IMic) have been recently developed in order to capture the spatial and the angular information of 3D microscopic samples with a single exposure. Computational post-processing of this information permits to carry out a 3D reconstruction of the sample. By applying conventional algorithms, both depth and also view reconstructions are possible. However, the main drawback of IMic is that the resolution of the reconstructed images is low and axially heterogeneous. In this paper, we propose a new configuration of the IMic by placing the lens array not at the image plane, but at the pupil (or Fourier) plane of the microscope objective. With this novel system, the spa…
Self-referenced phase reconstruction proposal of Ghz bandwidth non-periodical optical pulses by in-fiber semi-differintegration
2011
Abstract We propose two new techniques able to retrieve the phase profile of a given temporal optical pulse based on the use of in-fiber semi-differintegral operators, where by semi-differintegration we mean either a 0.5th-order differentiation or integration. In both cases, the signal's temporal phase can be obtained by simple dividing two temporal intensity profiles, namely the intensities of the input and output pulses of a spectrally shifted semi-differintegral operator. In both cases, we obtained simple analytical expressions for the phase profile. The techniques are self-referenced and well-suited for real-time applications. We numerically prove the viability of these proposals.
Event reconstruction methods for the HypHI Phase 0 experiment at GSI
2010
WOS: 000282530300034
Signal Characteristics of a Resistive-Strip Micromegas Detector with an Integrated Two-Dimensional Readout
2014
In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and high energy physics experiments. In this article, we present for the first time a systematic performance study of the signal characteristics of a resistive strip micromegas detector with a two-dimensional readout, based on test-beam and X-ray measurements. In particular, comparisons of the response of the two independent readout-layers regarding their signal shapes and signal reconstruction efficiencies are discussed.
A Unified Approach to High Density: Pion Fluctuations in Skyrmion Matter
2003
As the first in a series of systematic work on dense hadronic matter, we study the properties of the pion in dense medium using Skyrme's effective Lagrangian as a unified theory of the hadronic interactions applicable in the large $N_c$ limit. Dense baryonic matter is described as the ground state of a skyrmion matter which appears in two differentiated phases as a function of matter density: i) at high densities as a stable cubic-centered (CC) half-skyrmion crystal; ii) at low densities as an unstable face-centered cubic (FCC) skyrmion crystal. We substitute the latter by a stable inhomogeneous phase of lumps of dense matter, which represents a naive Maxwell construction of the phase trans…
Prototyping the PANDA Barrel DIRC
2014
The design of the Barrel DIRC detector for the future PANDA experiment at FAIR contains several important improvements compared to the successful BABAR DIRC, such as focusing and fast timing. To test those improvements as well as other design options a prototype was build and successfully tested in 2012 with particle beams at CERN. The prototype comprises a radiator bar, focusing lens, mirror, and a prism shaped expansion volume made of synthetic fused silica. An array of micro-channel plate photomultiplier tubes measures the location and arrival time of the Cherenkov photons with sub-nanosecond resolution. The development of a fast reconstruction algorithm allowed to tune construction deta…
UTSW Small Animal Positron Emission Imager
2006
A Small Animal Imager (SAI) for PET has been designed, built, tested in phantoms, and applied to investigations in mice and rats. The device uses principles based on gamma-ray induced scintillation in crossed fiber optic detectors connected to Position Sensitive Photomultiplier Tubes (PSPMT). Each detector consists of an epoxied stack of 28 layers of 135 round 1 mm BCF-10 scintillating plastic fibers. The overlap region forms a 13.5times13.5times2.8 cm3 detector volume. Scintillating light from the fibers is detected by two (X and Y directions) Hamamatsu R-2486 PSPMTs with 16 anode wires in each of two orthogonal directions. A centroid-finding algorithm gives the position of a light cluster…
A charge reconstruction algorithm for DAMPE silicon microstrip detectors
2019
Abstract The DArk Matter Particle Explorer (DAMPE) can detect electrons and photons from 5 GeV to 10 TeV and charged nuclei from a few tens of GeV to 100 TeV. The silicon–tungstentracker (STK), which is composed of 768 singled-sided silicon microstrip detectors, is one of four subdetectors in DAMPE providing photon conversion , track reconstruction, and charge identification for relativistic charged particles. This paper focuses on the charge identification performance of the STK detector. The charge response depends mainly on the incident angle and the impact position of the incoming particle. To improve the charge resolution, a reconstruction algorithm to correct for these parameters was …
The EM imaging reconstruction method in γ-ray astronomy
1998
Abstract The simpler imaging reconstruction methods used for γ-ray coded mask telescopes are based on correlation methods, very fast and simple-to-use but with limitations in the reconstructed image. To improve these results, other reconstruction methods have been developed, such as the maximum entropy methods or the Iterative Removal Of Sources (IROS). However, such kind of methods are slower and can be impracticable for very complex telescopes. In this paper we present an alternative image reconstruction method, based on an iterative maximum likelihood algorithm called the EM algorithm, easy to implement and that can be successfully used for not very complex coded mask systems, as is the …