Search results for "CONTACT"
showing 10 items of 1003 documents
Assessment of corneal thickness and tear meniscus during contact-lens wear
2014
To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…
Meibomian glands structure in daily disposable soft contact lens wearers: a one‐year follow‐up study
2020
Purpose To assess the impact of daily disposable soft contact lenses on meibomian gland morphology over a period of 12 months. Methods Forty-one subjects (33 experienced and 8 neophytes) were fitted with either silicone-hydrogel or hydrogel daily contact lenses. The study protocol included four visits: baseline, day-2 for contact lens fit and follow-up measurements, as well as after 6 and 12 months of lens wear. Non-contact infrared meibography images were acquired with Keratograph 5M topographer (www.oculus.de) and analysed with an automated method, which objectively estimates the area of gland atrophy, gland length and width, number of glands and gland irregularity. Protocol at follow-up …
Ocular surface assessment in soft contact lens wearers; the contribution of tear osmolarity among other tests.
2014
: Purpose: To determine whether tear osmolarity contributes to the assessment of the ocular surface in soft contact lens (CL) wearers. Methods: Prospective, case–control series in 44 CL wearers (28 tolerant and 16 intolerant) and 34 healthy subjects. Every patient underwent a thorough ophthalmic examination with a tear osmolarity test (TearLab System), conjunctival impression cytology and meibomian lipid sampling. Symptoms, break-up time (BUT), tear osmolarity, conjunctival expression of HLA-DR and meibomian fatty acid composition were evaluated. Results: Tear osmolarity did not differ between controls and CL wearers (p = 0.23). Flow cytometry results expressed in antibody-binding capaci…
Time expenditure in patient-related care provided by specialist palliative care nurses in a community hospice service
2004
Although the importance of specialist palliative care in home care programmes for terminally ill patients is well known, German community hospice services did not begin to employ nurses who had specialized in palliative care until the early 1990s. The general tasks of these nurses are sufficiently well defined, but no comprehensive data of their daily workload are available in Germany to date. The present article examines time expenditure in direct patient-related care at the community-based hospice service in Mainz, Germany, by analysing time registration sheets concerning 351 patients who received care from January 2000 until December 2002. Fifty-five per cent of care time spent on each …
Assessment of induced corneal hypoxia in diabetic patients
2002
Comparative Study Address correspondence and reprint requests to Dr. C. Creuzot-Garcher, Service d'Ophtalmologie, CHU, Hopital Général, 3 Rue du Faubourg Raines, BP 1519, 21033 Dijon, France. E-mail: Catherine.creuzot-garcher@chu-dijon.fr; To assess the control of corneal hydration in patients with diabetes during a contact lens-induced hypoxia. Corneal stress was induced in 15 patients with diabetes and 23 healthy patients by having them wear contact lenses for 2 hours. Pachymetries were measured and corneal parameters (percentage recovery per hour [PRPH], time for deswelling [T99%] and induced swelling [IS]) were calculated. In the mean time, tears were collected to assess the activity of…
The MOAHLFA index of irritant sodium lauryl sulfate reactions: first results of a multicentre study on routine sodium lauryl sulfate patch testing
2004
In a multicentre study of the German Contact Dermatitis Research Group, sodium lauryl sulfate (SLS) 0.25% and 0.5% aq. has been added to routine allergen patch tests to assess its properties as a convenient diagnostic indicator of individual susceptibility to irritation at the time of patch testing. Previous studies indicated that irritant SLS reactivity may be related to individual factors such as age and sex. As these factors are, in turn, among the important predictors of contact allergy to many allergens, e.g. summarized in the 'MOAHLFA index', the impact of the MOAHLFA factors on irritant SLS patch test reactivity, and thus a potential for confounding, was assessed in the 5971 particip…
Prevention and early detection of tuberculosis
1996
1,570 subjects with known TB contacts (active TB, old TB and primary infection) and individuals with no known contacts but belonging to 'defined TB risk groups' were screened at the Department of Tuberculosis Prevention at the La Fe Hospital in Valencia. The total infection rate was 40.13% and active TBC was diagnosed in 2.23% of the population screened. Infection and disease rates were significant in all the groups examined, showing the need for correct screening not only for active TB contacts but also for child primary infection contacts, old TB cases not previously screened and subjects with no known contacts but belonging to a 'TB risk group'.
Post-LASIK Visual Quality With a Corneoscleral Contact Lens to Treat Irregular Corneas.
2015
To evaluate the visual quality results of fitting a corneoscleral contact lens with multiaspheric geometry design (MAGD CScL) in subjects with irregular corneas after laser-assisted in situ keratomileusis (LASIK) surgery.From a database of patients evaluated for scleral contact lenses, we identified those with irregular corneas and visual problems after they underwent LASIK surgery for correcting myopia. They manifested unsatisfactory visual quality with their current contact lenses or glasses. Therefore, a MAGD CScL was fitted and monitored according to standardized fitting methodology. A diagnostic trial set was used in the fitting process. Visual acuity (VA), subjective visual quality (S…
Allogenic simple limbal epithelial transplantation (alloSLET) from cadaveric donor eyes in patients with persistent corneal epithelial defects
2020
Background/aimTo describe the clinical outcome of allogenic simple limbal epithelial transplantation (alloSLET) utilising tissue from cadaveric donor eyes after failed re-epithelialisation of the corneal surface.MethodsMedical records of 14 eyes from 14 patients treated for persistent corneal epithelial defects with alloSLET were reviewed. The primary outcome measure was complete epithelialisation of the corneal surface. Secondary outcome measures were best corrected visual acuity (BCVA) and postoperative side effects due to surgery or medical therapy.ResultsOf the 14 eyes, 7 received alloSLET only and 7 alloSLET together with penetrating keratoplasty (PK). Thirteen (92.9%) of 14 eyes had a…
Effect of 3rd-order aberrations on human vision
2007
To investigate the effect of 3rd-order aberrations on human vision.Grupo de Ciencias de la Visión, University of Murcia, Murcia, Spain.The 3rd-order aberrations coma and trefoil were induced with purpose-designed soft contact lenses, 3 inducing coma (low [0.05 microm], medium [0.13 microm], high [1.03 microm]) and 3 inducing trefoil (low [0.07 microm], medium [0.17 microm], high [0.96 microm]). Monocular high-contrast (HCVA) and low-contrast (LCVA) visual acuities and contrast sensitivity were measured in 11 subjects wearing contact lenses with a 5.0 mm artificial pupil.The reduction in HCVA and LCVA was statistically significant only for the highest coma and trefoil values (P.0001). For co…