Search results for "CONTACT"
showing 10 items of 1003 documents
Patch testing with components of water-based metalworking fluids
2003
Water-based metalworking fluids (MWFs) may cause both irritant and allergic contact dermatitis. Several well-known MWF allergens are available for patch testing, but considering the wide variety of possible components used in MWF, our diagnostic arsenal covers only a small part of potential allergens. We therefore selected 13 frequently used MWF components that might be sensitizers and had not yet been tested routinely. In 5 centres, 233 dermatitis patients with present or past occupational exposure to MWF were patch tested with this and other panels. Only 7 patients showed positive reactions to the study panel. Allergic reactions to the emulsifier diglycolamine [syn. 2-(2-aminoethoxy) etha…
The impact of rear-view mirror distance and curvature on judgements relevant to road safety
2011
We report two experiments that investigate the impact of rear-view mirror distance and curvature on distance, spacing, and time-to-contact (TTC) judgements. The variation in mirror distance had a significant effect on TTC judgements, but only marginally influenced distance and spacing estimations. As mirror distance increased, TTC was overestimated, which is potentially dangerous. Control conditions with identical visual angles across different mirror distances revealed that effects were not solely caused by variation in visual angle. The impact of mirror curvature moderated the effect. While observers were unable to compensate for the mirror distance effect, they could do so for the distor…
Anxiety and facial self-contacts: possible impact on COVID-19 transmission in dental practice
2021
Abstract Background The purpose was to analyse the associations between dental and trait anxiety, fear of COVID-19 and the duration and frequency of spontaneous hand-to-face contact (self-contact). Methods A cross-sectional design was carried out with 128 adult patients from four dental clinics in Madrid, during the confinement, from March 15 to May 15. The patients’ movements in the waiting room were monitored with Microsoft Kinect Software, also completed the Trait anxiety subscale of the STAI, the COVID-19 Fear and the S-DAI questionnaire. Results Associations were observed between the duration and frequency of facial, mask and eye contact with trait anxiety and dental fear was determine…
Men with elevated testosterone levels show more affiliative behaviors during contact with women
2012
Testosterone (T) is thought to play a key role in male–male competition and courtship in many vertebrates, but its precise effects are unclear. We explored whether courtship behaviour in humans is modulated and preceded by changes in T. Pairs of healthy male students first competed in a non-physical contest in which their T levels became elevated. Each participant then had a short, informal interaction with either an unfamiliar man or woman. The sex of the stimulus person did not affect the participants' behaviour overall. However, in interactions with women, those men who had experienced a greater T increase during the contest subsequently showed more interest in the woman, engaged in more…
Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.
2015
Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Emotional communication in the context of joint attention for food stimuli: Effects on attentional and affective processing
2014
Guided by distinct theoretical frameworks (the embodiment theories, shared-signal hypothesis, and appraisal theories), we examined the effects of gaze direction and emotional expressions (joy, disgust, and neutral) of virtual characters on attention orienting and affective reactivity of participants while they were engaged in joint attention for food stimuli contrasted by preference (disliked, moderately liked, and liked). The participants were exposed to videos of avatars looking at food and displaying facial expressions with their gaze directed either toward the food only or toward the food and participants consecutively. We recorded eye-tracking responses, heart rate, facial electromyogr…
Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.
2019
Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…
Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes
2019
Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…