Search results for "CONTRAST"

showing 10 items of 1162 documents

Statistical analysis of life history calendar data

2016

The life history calendar is a data-collection tool for obtaining reliable retrospective data about life events. To illustrate the analysis of such data, we compare the model-based probabilistic event history analysis and the model-free data mining method, sequence analysis. In event history analysis, we estimate instead of transition hazards the cumulative prediction probabilities of life events in the entire trajectory. In sequence analysis, we compare several dissimilarity metrics and contrast data-driven and user-defined substitution costs. As an example, we study young adults' transition to adulthood as a sequence of events in three life domains. The events define the multistate event…

AdultMaleStatistics and ProbabilityAdolescentEpidemiologyComputer sciencedistance-based dataDisease clustercomputer.software_genre01 natural sciencesLife Change EventsYoung Adult010104 statistics & probability0504 sociologyHealth Information Managementprediction probabilityStatisticsData MiningHumansLongitudinal StudiesProspective Studieslife history calendar multidimensional sequence analysis0101 mathematicsFinlandSurvival analysisProbabilityRetrospective StudiesSequence (medicine)Complement (set theory)ta112DepressionData Collection05 social sciencesProbabilistic logic050401 social sciences methodsContrast (statistics)multistate modelMiddle ageLife course approachFemaleData mininglife history calendarlife course analysiscomputermultidimensional sequence analysisStatistical Methods in Medical Research
researchProduct

FAIR and dynamic susceptibility contrast-enhanced perfusion imaging in healthy subjects and stroke patients.

2002

Purpose To compare dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI) and the flow-sensitive alternating inversion recovery (FAIR) technique for measuring brain perfusion. Materials and Methods We investigated 12 patients with acute stroke, and 10 healthy volunteers with FAIR and DSC maps of regional cerebral blood volume (rCBV), mean transit time (MTT), and regional cerebral blood flow (rCBF). Results In volunteers good gray/white-matter contrast was observed in FAIR, rCBF, and rCBV maps. Regions with high signal intensities in FAIR matched well with high values of rCBV and rCBF. In ischemic stroke patients a high correlation (r = 0.78) of the ipsi- to contralate…

AdultMaleStroke patientContrast MediaPerfusion scanningmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedmedicine.diagnostic_testbusiness.industryHealthy subjectsMagnetic resonance imagingMiddle AgedMagnetic Resonance ImagingStrokeCerebral blood volumeCerebral blood flowRegional Blood FlowCase-Control StudiesCerebrovascular CirculationAcute DiseaseFemaleNuclear medicinebusinessPerfusionDynamic susceptibilityJournal of magnetic resonance imaging : JMRI
researchProduct

Wall patterns influence the perception of interior space

2019

The texture of an object’s surface influences its perceived spatial extent. For example, Hermann von Helmholtz reported that a square patch with black and white stripes appears elongated perpendicular to the stripes’ orientation. This time-honoured finding stands in contrast with more recent recommendations by interior-design experts who suggest that stripe wall patterns make rooms appear elongated in the direction parallel to the stripes’ orientation. In a series of four experiments, we presented stripe wall patterns and varied the orientation of the stripes (horizontal vs. vertical) and their density (number of stripes per degree of visual angle). Subjects estimated the width and height …

AdultMaleSurface (mathematics)AdolescentPhysiologymedia_common.quotation_subjectExperimental and Cognitive PsychologyGeometryTexture (geology)Young AdultCondensed Matter::SuperconductivityPhysiology (medical)Orientation (geometry)PerceptionPerpendicularHumansContrast (vision)Pattern orientationOrientation SpatialGeneral Psychologymedia_commonPhysicsGeneral MedicineMiddle AgedNeuropsychology and Physiological PsychologySpace PerceptionFemaleVisual anglePhotic StimulationInterior Design and FurnishingsQuarterly Journal of Experimental Psychology
researchProduct

Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact…

2020

Purpose To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. Methods A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 +/- 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-…

AdultMaleTime FactorsAdolescentgenetic structuresVisual qualityControl (management)Visual AcuityVisual performanceLight disturbanceContrast Sensitivity03 medical and health sciencesYoung Adult0302 clinical medicineDouble-Blind MethodMyopiaHumansMiSightCross-Over StudiesScience & TechnologyColor VisionMultifocal contact lensContact Lenses HydrophilicSensory Systemseye diseasesTerm (time)Contact lensOphthalmologyScholarship030221 ophthalmology & optometryOptometryFemalePsychology030217 neurology & neurosurgeryMyopia controlOptometryFollow-Up Studies
researchProduct

Parafoveal versus foveal N400s dissociate spreading activation from contextual fit.

2009

Using concurrent electroencephalogram and eye movement measures to track natural reading, this study shows that N400 effects reflecting predictability are dissociable from those owing to spreading activation. In comparing predicted sentence endings with related and unrelated unpredicted endings in antonym constructions ('the opposite of black is white/yellow/nice'), fixation-related potentials at the critical word revealed a predictability-based N400 effect (unpredicted vs. predicted words). By contrast, event-related potentials time locked to the last fixation before the critical word showed an N400 only for the nonrelated unpredicted condition (nice). This effect is attributed to a parafo…

AdultMaleTime Factorsgenetic structuresmedia_common.quotation_subjectVocabularyPsycholinguisticsThinkingYoung AdultFovealContrast (vision)HumansPredictabilityEvoked PotentialsEye Movement Measurementsmedia_commonCommunicationbusiness.industryGeneral NeuroscienceEye movementBrainElectroencephalographyN400SemanticsReadingFixation (visual)FemalebusinessPsychologySentenceCognitive psychologyNeuroreport
researchProduct

Visual distraction: a behavioral and event-related brain potential study in humans.

2006

Recent studies reported that the detection of changes in the visual stimulation results in distraction of cognitive processing. From event-related brain potentials it was argued that distraction is triggered by the automatic detection of deviants. We tested whether distraction effects are confined to the detection of a deviation or can be triggered by changes per se, namely by rare stimuli that were not deviant with respect to the stimulation. The results obtained comparable early event-related brain potential effects for rare and deviant stimuli, suggesting an automatic detection of these changes. In contrast, behavioral distraction and attention-related event-related brain potential compo…

AdultMaleTime Factorsmedia_common.quotation_subjecteducationMismatch negativityPoison controlStimulationbehavioral disciplines and activitiesDevelopmental psychologyDiscrimination PsychologicalPerceptionDistractionmental disordersReaction TimeContrast (vision)HumansAttentionmedia_commonBrain MappingGeneral NeuroscienceBrainCognitionElectroencephalographyhumanitiesElectrophysiologyPattern Recognition VisualEvoked Potentials VisualFemalePsychologyNeurosciencepsychological phenomena and processesPhotic StimulationPsychomotor PerformanceNeuroreport
researchProduct

Visual performance of two simultaneous vision multifocal contact lenses

2012

Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…

AdultMaleVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual Acuitylaw.inventionContrast SensitivitylawmedicineHumansContrast (vision)media_commonVision BinocularCross-Over Studiesbusiness.industryIntermediate distanceBoth lensesPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyOptometryFemalemedicine.symptombusinessOptometryPhotopic visionOphthalmic and Physiological Optics
researchProduct

Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.

2007

To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…

AdultMaleVisual acuitygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularMedicineContrast (vision)HumansProspective Studiesmedia_commonAgedQuality Indicators Health CareAged 80 and overLenses IntraocularVision BinocularMonocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyQuality of visionOptometrySurgeryFemalesense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual function after implantation of a diffractive aspheric trifocal intraocular lens

2016

Purpose To evaluate distance, intermediate, and near vision after bilateral implantation of a diffractive aspheric trifocal intraocular lens (IOL). Methods This study enrolled 204 eyes of 102 patients who had bilateral implantation of the AT LISA tri 839MP IOL. Monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (4 meters), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (30, 40 centimeters), binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) (50, 60, 70 centimeters), the defocus curve, and binocular photopic…

AdultMaleVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignRefraction OcularGlareContrast Sensitivity03 medical and health sciencesNear visionOcular physiology0302 clinical medicineLens Implantation IntraocularMedicineHumansProspective StudiesAgedLenses IntraocularVision BinocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationMiddle Agedeye diseasesOphthalmologyVisual function030221 ophthalmology & optometryOptometryFemalemedicine.symptombusinessBinocular vision030217 neurology & neurosurgeryPseudophakia
researchProduct

Diurnal variations in visual performance for disposable contact lenses.

2013

The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (JohnsonJohnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (JohnsonJohnson Vision Care), SofLens daily disposable (BauschLomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti …

AdultMaleVisual acuitygenetic structuresmedia_common.quotation_subjectVisual AcuityContrast SensitivityYoung AdultmedicineMyopiaContrast (vision)HumansDisposable EquipmentVision Ocularmedia_commonMathematicsContact Lenses Hydrophiliceye diseasesCircadian RhythmOphthalmologyOptometryDaily disposableFemalesense organsDisposable Equipmentmedicine.symptomOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct