Search results for "COU"
showing 10 items of 14566 documents
System for control of polarization state of light and generation of light with continuously rotating linear polarization
2019
We present a technique for generating light in an arbitrary polarization state. The technique is based on interference of two orthogonally polarized light beams, whose amplitudes and phases are controlled with a Mach-Zehnder inteferometer with acousto-optic modulators (AOMs) placed in each arm. We demonstrate that via control over amplitudes, phases, and frequencies of acoustic waves driving the AOMs, any polarization state can be synthesized. In particular, we demonstrate generation of linearly polarized light, whose polarization plane continuously rotates at a rate from 1 kHz to 1 MHz. Such light finds applications in science (e.g., investigations of Bloch-Siegert effect) and technology (…
2019
We present a design for producing precisely adjustable and alternating single-axis magnetic fields based on nested Halbach dipole pairs consisting of permanent magnets only. Our design allows for three dimensional optical and mechanical access to a region with strong adjustable dipolar fields, is compatible with systems operating under vacuum, and does not effectively dissipate heat under normal operational conditions. We present a theoretical analysis of the properties and capabilities of our design and construct a proof-of-concept prototype. Using our prototype, we demonstrate fields of up to several kilogauss with field homogeneities of better than 5%, which are harmonically modulated at…
Enhanced acoustic pressure sensors based on coherent perfect absorber-laser effect
2021
Lasing is a well-established field in optics with several applications. Yet, having lasing or huge amplification in other wave systems remains an elusive goal. Here, we utilize the concept of coherent perfect absorber-laser to realize an acoustic analog of laser with a proven amplification of more than 10 4 in terms of the scattered acoustic signal at a frequency of a few kHz. The obtained acoustic laser (or the coherent perfect absorber-laser) is shown to possess extremely high sensitivity and figure of merit with regard to ultra-small variations of the pressure (density and compressibility) and suggests its evident potential to build future acoustic pressure devices such as precise sensor…
Thermal cloaking of complex objects with the neutral inclusion and the coordinate transformation methods
2019
We explore the cloaking of a complex shape by either the neutral inclusion or the transformation thermodynamics (TT) methods. Thin cloaks are built and the heat cloaking efficiency is investigated for both the steady-state and the transient regimes. We show that the neutral inclusion cloak is more efficient in both regimes, though it has the drawback that the thermal conductivity of the cloaked shape must be known. In practice, the neutral inclusion method is more flexible and easier to implement than the coordinate transformation method, especially for complex shapes.We explore the cloaking of a complex shape by either the neutral inclusion or the transformation thermodynamics (TT) methods…
Fundamental Noise Limits and Sensitivity of Piezoelectrically Driven Magnetoelastic Cantilevers
2020
International audience; Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic fields are in the focus of research for more than 30 years. In order to minimize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this contribution, cantilever-type electromechanical and magnetoelastic resonators, respectively, are comprehensively investigated and mathematically described not only with regard to their phase sensitivity but especially to the extent of the sensor-intrinsic phase noise. Both measurements and calculations reveal that the fundamental LOD is limited by addi…
Microfabricated high temperature sensing platform dedicated to scanning thermal microscopy (SThM)
2018
Abstract The monitoring of heat flux is becoming more and more critical for many materials and structures approaching nanometric dimensions. Scanning Thermal Microscopy (SThM) is one of the tools available for thermal measurement at the nanoscale and requires calibration. Here we report on a micro-hotplate device made of a platinum heater suspended on thin silicon nitride (SiN) membranes integrating specific features for SThM calibration. These heated reference samples can include a localized resistive temperature sensors (RTD) or standalone platinum membranes (typically 10 × 10 μm2) on which the temperature can be measured precisely. This functional area is dedicated to (1) estimate the th…
Luminescence characteristics of magnesium aluminate spinel crystals of different stoichiometry
2019
We are grateful to Drs E. Vasil’chenko and A. Maaroos for the help with experiments and useful discussions. This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014-2018 under grant agreement No 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission. In addition, the research leading to these results has received funding from the Estonian Research Council Institutional Research Funding IUT02-26.
Metrological Properties of the Test Setup for Determination Shielding Effectiveness of the Industrial Cable Connectors
2017
Abstract The paper presents results related to assessment of the repeatability and reproducibility of the measurement test setup for determination the relative value of the shielding effectiveness coefficient of the industrial connectors. The construction of the proposed test setup, the measurement method and the procedure for the analysis of measurement results were described. To determine the value of the repeatability and reproducibility coefficient, the two–way analysis of variance was used, which additionally allows for an assessment of the influence of individual sources of variance. The measurements and their analysis were conducted for several frequencies in the range up to 1 GHz. A…
Acoustic Wave Behavior in a Specimen Containing an Air Void Defect
2019
The PEA method is the most used technique for the space charge measurements. As is well known, this method uses pressure waves to detect the charges accumulated in solid dielectrics. Based on its working principle, the generated acoustic waves travel within PEA cell and the specimen under test in order to be finally detected by the piezoelectric sensor. For a multilayer specimen and, in particular, in case of different materials that make up the specimen, the acoustic wave reflection is inevitable. Considering that, in several cases, the reflected waves could be detected by the piezoelectric sensor before than the main signals, the PEA cell output profile could results distorted. Based on t…
Ultrasonic nebulization inductively coupled plasma optical emission spectrometry method for wine analysis
2020
Abstract A methodology was developed to determine mineral elements in wines using Inductively Coupled Plasma Optical Emission Spectrometry combined with ultrasonic nebulization. The concentration of 36 elements (Al, B, Ba, Bi, Ca, Cd, Ce, Co, Cr, Dy, Er, Eu, Fe, Gd, K, La, Lu, Mg, Mn, Mo, Na, Nd, Ni, Pb, Pr, Sb, Sc, Sm, Sr, Tb, Ti, Tm, V, Y, Yb, and Zn) was determined in 59 wine samples and used to distinguish between Brazilian and Spanish wines. The best conditions for the plasma were selected using a two-level factorial design: radiofrequency power 1500 W; plasma gas flow rate 15 L min−1; auxiliary 0.70 L min−1; and nebulizer 0.40 L min−1. An exploratory multivariate analysis by Principal…