Search results for "Calibration"

showing 10 items of 890 documents

Cubic smoothing splines background correction in on-line liquid chromatography–Fourier transform infrared spectrometry

2010

A background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry (LC-FTIR) is proposed. The developed approach applies univariate background correction to each variable (i.e. each wave number) individually. Spectra measured in the region before and after each peak cluster are used as knots to model the variation of the eluent absorption intensity with time using cubic smoothing splines (CSS) functions. The new approach has been successfully tested on simulated as well as on real data sets obtained from injections of standard mixtures of polyethylene glycols with four different molecular weights in methanol:water, 2-propano…

Analytical chemistrySensitivity and SpecificityBiochemistryPolyethylene GlycolsAnalytical ChemistryMatrix (chemical analysis)ChemometricsSmoothing splinesymbols.namesakeSpectroscopy Fourier Transform InfraredCalibrationComputer SimulationFourier transform infrared spectroscopyAnalysis of VarianceChromatographyElutionChemistryOrganic ChemistryGreen Chemistry TechnologyGeneral MedicineFourier transformAlcoholsLinear ModelssymbolsBackground Correction MethodAlgorithmsChromatography LiquidJournal of Chromatography A
researchProduct

A method for the surface reflectance retrieval from PROBA/CHRIS data over land: application to ESA SPARC campaigns

2005

The Compact High Resolution Imaging Spectrometer (CHRIS) onboard the Project for On-Board Autonomy (PROBA) platform system provides the first high spatial resolution hyper-spectral/multiangular remote sensing data from a satellite system, what represents a new source of information for Earth Observation purposes. A fully consistent radiative transfer approach is always preferred when dealing with the retrieval of surface reflectance from hyperspectral/multiangular data. However, due to the reported calibration anomalies for CHRIS data, a direct atmospheric correction based on physical radiative transfer modeling is not possible, and the method must somehow compensate for such calibration pr…

Ancillary dataEarth observationSpectrometerAtmospheric correctionRadiative transferCalibrationGeneral Earth and Planetary SciencesHyperspectral imagingEnvironmental science550 - Earth sciencesElectrical and Electronic EngineeringImage resolutionRemote sensingIEEE Transactions on Geoscience and Remote Sensing
researchProduct

Characterization and determination of poly(vinylpyrrolidone) by complexation with an anionic azo-dye and nonequilibrium capillary electrophoresis

2009

Using capillary zone electrophoresis in nonequilibrium conditions, the complexes of poly(vinylpyrrolidone) (PVP) with anionic azo-dyes dissociate following a first-order kinetics. Two peaks due to the remaining PVP-dye complexes and the equilibrium concentration of the free dye, plus an exponential region due to the dye liberated by the complexes during the electrophoretic run, are obtained. This behaviour was closely similar to that described in the literature for protein-probe and DNA-protein mixtures, upon application of the technique known as nonequilibrium capillary electrophoresis of equilibrium mixtures or NECEEM. Using Congo Red and Acid Blue 113, information about the maximal stoic…

AnionsDetergentsKineticsmacromolecular substancesBiochemistryAnalytical Chemistrychemistry.chemical_compoundCapillary electrophoresisColoring Agentschemistry.chemical_classificationChromatographyMolecular massPolymer characterizationOrganic Chemistrytechnology industry and agricultureElectrophoresis CapillaryPovidoneGeneral MedicinePolymerCongo redMolecular WeightKineticsElectrophoresischemistryCalibrationAzo CompoundsStoichiometryJournal of Chromatography A
researchProduct

Determination of antimony in drinking waters by an inexpensive, reproducible hydride generator for atomic spectroscopy.

1991

A method for determining antimony in drinking waters is described. In order to prevent a substantial error caused by the different oxidation states of antimony, Sb(V) is reduced to Sb(III) with potassium iodide-ascorbic acid. Covalent hydride is generated with a home made device by adding NaBH4. The hydride is then atomized in a flame-heated silica tube and atomic absorption is measured spectrophotometrically. The optimal conditions for this determination are discussed and interference effects are described. Results obtained by determining linearity range (0-200 ng), detection (LOD) and quantitation (LOQ) limits (LOD = 0.347 ng/ml, LOQ = 1.158 ng/ml), precision (instrumental CV 4.08% and me…

Antimonymedicine.diagnostic_testHydridePotassiumSpectrophotometry AtomicAnalytical chemistrychemistry.chemical_elementReproducibility of ResultsOxidation reductionAtomic spectroscopyHydrogen-Ion Concentrationlaw.inventionKineticschemistryAntimonylawPredictive Value of TestsWater SupplySpectrophotometryCalibrationCalibrationmedicineAtomic absorption spectroscopyOxidation-ReductionFood ScienceDie Nahrung
researchProduct

Extraction of polyphenols in Himanthalia elongata and determination by high performance liquid chromatography with diode array detector prior to its …

2016

Abstract Several studies have demonstrated the antioxidant capacity of seaweeds, which can be used for the development of biopharmaceuticals with extensive medical application. Antioxidant therapies appear to attenuate the organic deterioration originated by an excessive oxidative stress, which could prevent the harmful effects of various injuries such as ischemia-reperfusion (I/R) among others. Marine brown seaweeds play a significant role, as they are the only organisms on earth producing phlorotannins, which are polyphenols that exhibit important biological activity. To ensure obtaining an extract with the greatest antioxidant activity, some variables that affect the extraction of polyph…

AntioxidantTime Factorsmedicine.medical_treatmentClinical BiochemistryPhaeophytaBiochemistryAntioxidantsAnalytical Chemistrychemistry.chemical_compound0404 agricultural biotechnologyChlorogenic acidLimit of DetectionmedicineCaffeic acidGallic acidGentisic acidChromatography High Pressure LiquidChromatography Reverse-PhaseChromatographyTemperaturefood and beveragesPolyphenolsReproducibility of ResultsCatechin04 agricultural and veterinary sciencesCell BiologyGeneral MedicineFree Radical ScavengersSeaweed040401 food scienceOxidative StresschemistryPolyphenolCalibrationMyricetinJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Mark-Houwink Parameters of Biosynthetic Poly(γ-glutamic acid) in Aqueous Solution

2001

A combined viscosity–light scattering–gel permeation chromatography (GPC) study was carried out on bacterially produced poly(γ-glutamic acid) (PGGA). PGGA samples with weight-average molecular weights ranging from 8×104 up to 8×105 g·mol–1 dissolved in phosphate buffer at 0.13 M ionic strength were used. It was found that the Mark–Houwink relation is acceptably obeyed, giving K and a values of 1.84×10–6 dL·g–1 and 1.16, respectively. As expected, GPC analysis showed that PGGA does not follow the universal calibration plot and that deviations can not be avoided by modifying the ionic strength.

Aqueous solutionChromatographyPolymers and PlasticsMolecular massChemistryCalibration curveOrganic ChemistryMark–Houwink equationGlutamic acidPermeationCondensed Matter PhysicsIonic strengthMaterials ChemistryA valuePhysical and Theoretical ChemistryMacromolecular Chemistry and Physics
researchProduct

Microheterogeneous electrocatalytic chiral recognition at monoclinic vanadium-doped zirconias: enantioselective detection of glucose.

2007

Synthetic tetragonal and monoclinic vanadium-doped zirconias (t- and m-VxZr1-xO2, 0.005x0.150) exert an effective catalytic effect toward the electrochemical oxidation of glucose in aqueous alkaline media. The catalytic effect of monoclinic specimens attached to carbon and fluorine-doped tin oxide electrodes exhibits a remarkable enantioselectivity, so that catalytic currents for the oxidation of L-glucose at +0.92 V vs AgCl/Ag are considerably larger than those obtained for the oxidation of D-glucose. This enantioselectivity can be associated with the existence of a noncentrosymmetric coordination of vanadium centers in the monoclinic crystalline form of zirconia. From the electrochemical …

Aqueous solutionMolecular StructureChemistryInorganic chemistryVanadiumchemistry.chemical_elementElectronsStereoisomerismVanadiumElectrocatalystTin oxideElectrochemistryCatalysisAnalytical ChemistryCatalysisGlucoseMicroscopy Electron TransmissionCalibrationElectrochemistryMicroscopy Electron ScanningCubic zirconiaZirconiumOxidation-ReductionMonoclinic crystal systemAnalytical chemistry
researchProduct

The relationship between water and air temperature in chironomid-based paleoclimate reconstructions: Records from boreal and subarctic Finland

2014

Fossil remains of larval chironomids are one of the most useful paleolimnological proxies to reconstruct Holocene paleoclimate. We investigate the within-lake distribution of chironomids in relation to water temperature and test the usability of intralake calibration in chironomid-based temperature reconstructions. We compare our findings against the traditional multilake calibration technique in Holocene sediment cores from Finland. The results show that intralake water temperature optima of common taxa correspond closely with mean July air temperature optima in a regional multilake dataset, with exception of a few vegetation-associated taxa. A calibration model based on intralake water t…

ArcheologyGlobal and Planetary ChangeEcologyCalibration (statistics)ta1171PaleontologySediment15. Life on landSubarctic climatePaleolimnologyBoreal13. Climate actionClimatologyPaleoclimatologyIce ageEnvironmental scienceta1181HoloceneEarth-Surface ProcessesHolocene
researchProduct

An innovative approach to manage uncertainties and stock diversity in the EPBD cost-optimal methodology

2018

The EU Energy Performance of Buildings Directive (EPBD) 2010/31/EU is a step in the right direction to promote near zero energy buildings (NZEB) in a step-wise manner, starting with minimum energy performance and cost optimal thresholds for “reference buildings” (RBs) for each category. Nevertheless, a standard method for defining RBs does not exist, which led to a great divergence between MS in the level of detail used to define RBs for the EPBD cost-optimal analysis. Such lack of harmonisation between MS is further evident given the resulting large discrepancies in energy performance indicators even between countries having similar climate. Furthermore, discrepancies of 30% or higher betw…

Architecture and energy conservationZero-energy buildingSettore ING-IND/11 - Fisica Tecnica AmbientaleOperations researchStock modelling EPBD cost-optimal method Bayesian calibration reference zonesEnergy performance indicatorsbusiness.industryComputer scienceBayesian probabilityEnergy performanceEngineering MultidisciplinaryMühendislik Ortak DisiplinlerBuildings -- Energy conservationDirectiveSoftwareStock modellingEPBD cost-optimal methodBayesian calibrationreference zonesBuildings -- Energy conservation -- European Union countriesSustainable buildings -- Design and construction -- StandardsbusinessZoningBuildings -- Thermal propertiesStock (geology)
researchProduct

Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory

2013

The Pierre Auger Observatory in Malargue, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, lo…

AstronomyDetector alignment and calibration methods (lasers sources particle-beams)01 natural sciencesDetector alignment and calibration methods (laserObservatoryATMOSPHERIC CONDITIONSDetector alignment and calibration methodsInstrumentationcosmic rayMathematical PhysicsHigh Energy Astrophysical Phenomena (astro-ph.HE)Physicsatmospheric monitoring[SDU.ASTR.HE]Sciences of the Universe [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]PhysicsData analysiparticle-beams)ComputingMethodologies_DOCUMENTANDTEXTPROCESSINGCentral Laser FacilityFísica nuclearAstrophysics - Instrumentation and Methods for AstrophysicsAstrophysics - High Energy Astrophysical Phenomenasources[PHYS.ASTR.HE]Physics [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE][PHYS.ASTR.IM]Physics [physics]/Astrophysics [astro-ph]/Instrumentation and Methods for Astrophysic [astro-ph.IM]sourceAuger Experimentaerosols * Authors are listed on the following pagesData analysisFOS: Physical sciencesCosmic rayAuger Experiment; cosmic rays; atmospheric monitoring; aerosolsOpticscosmic raysUltra-high energy cosmic rays. atmospheric monitoring. aerosols0103 physical sciences010306 general physicsInstrumentation and Methods for Astrophysics (astro-ph.IM)Pierre Auger Observatory010308 nuclear & particles physicsbusiness.industryLarge detector systems for particle and astroparticle physicsAttenuationAtmospheric correctionUltra-high energy cosmic rays[SDU.ASTR.IM]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Instrumentation and Methods for Astrophysic [astro-ph.IM]AerosolDetector alignment and calibration methods (lasersAir showerdetector alignment and calibration methods (lasers; sources; particle-beams); large detector systems for particle and astroparticle physics; data analysisExperimental High Energy PhysicsLarge detector systems for particle and astroparticle physicbusinessRAIOS CÓSMICOSaerosolsSYSTEM
researchProduct