Search results for "Calibration"
showing 10 items of 890 documents
Optical interfaces in GD-OES system for vacuum far ultraviolet detection
2003
A Glow Discharge Optical Emission Spectrometry device has been designed for glove box adaptation in CEA Valduc to analyze carbon, hydrogen, nitrogen and oxygen at low concentration in nuclear materials. Vacuum ultraviolet region of the spectrum (between 120 and 160 nm) was chosen for light elements analysis with the aim to avoid optical interferences with matrix emission lines (20000 lines in the visible region for plutonium element). For this purpose, two different systems of collection have been developed: a first based on two focusing lenses and a second having an optical interface based on mirrors. In the present paper, the whole set-up integrated in a glove box is described. Optical li…
Model-based biotechnological potential analysis of Kluyveromyces marxianus central metabolism
2016
Abstract The non-conventional yeast Kluyveromyces marxianus is an emerging industrial producer for many biotechnological processes. Here, we show the application of a biomass-linked stoichiometric model of central metabolism that is experimentally validated, and mass and charge balanced for assessing the carbon conversion efficiency of wild type and modified K. marxianus. Pairs of substrates (lactose, glucose, inulin, xylose) and products (ethanol, acetate, lactate, glycerol, ethyl acetate, succinate, glutamate, phenylethanol and phenylalanine) are examined by various modelling and optimisation methods. Our model reveals the organism’s potential for industrial application and metabolic engi…
Testing Hadronic Interactions at Ultrahigh Energies with Air Showers Measured by the Pierre Auger Observatory
2016
Ultrahigh energy cosmic ray air showers probe particle physics at energies beyond the reach of accelerators. Here we introduce a new method to test hadronic interaction models without relying on the absolute energy calibration, and apply it to events with primary energy 6-16 EeV (ECM=110-170 TeV), whose longitudinal development and lateral distribution were simultaneously measured by the Pierre Auger Observatory. The average hadronic shower is 1.33±0.16 (1.61±0.21) times larger than predicted using the leading LHC-tuned models EPOS-LHC (QGSJetII-04), with a corresponding excess of muons.
Correction: Phylogeny of the Eurasian Wren Nannus troglodytes (Aves: Passeriformes: Troglodytidae) reveals deep and complex diversification patterns …
2020
The Mediterranean Basin represents a Global Biodiversity Hotspot where many organisms show high inter- and intraspecific differentiation. Extant phylogeographic patterns of terrestrial circum-Mediterranean faunas were mainly shaped through Pleistocene range shifts and range fragmentations due to retreat into different glacial refugia. Thus, several extant Mediterranean bird species have diversified by surviving glaciations in different hospitable refugia and subsequently expanded their distribution ranges during the Holocene. Such a scenario was also suggested for the Eurasian Wren (Nannus troglodytes) despite the lack of genetic data for most Mediterranean subspecies. Our phylogenetic mult…
A program for the simultaneous potentiometric determination of protonation constants and electrode calibration parameters
2005
A program for the potentiometric determination of the protonation constants of mononuclear polyprotic substances is described. A maximum of twelve parameters can be determined simultaneously, including up to six protonation constants, four electrode calibration parameters, the protolysis constant of the solvent and the titrant concentration. Optimization is carried out by using the non-simplified Newton-Raphson method, which is potentiated by the Marquardt algorithm and a distance speeding-up coefficient. A direct search method is also used to improve the initial set of values. Variances are calculated very accurately, since the real Hessian function is used. Statistical weights and ionic s…
Immobilization of Hexacyanoferrate (III) for a Flow Injection-Spectrophotometric Determination of Promazine
1993
Abstract An automated flow injection method for the determination of promazine is described. The method is based on the oxidation of promazine by hexacyanoferrate (III) and spectrophotometric monitorization of oxidized drug. The chemical and FIA variables were optimized. The calibration graph was linear over the concentration range 2,5–25 ppm of promazine hydrochloride. Some interfering substances were also investigated. The method was applied for the determination of promazine in pharmaceutical formulations.
Evaluation of activated sludge model no.2 at high phosphorus concentrations
2001
This paper presents laboratory scale experimentation carried out to study enhanced biological phosphorus removal at high phosphorus concentrations in a sequencing batch reactor. Four series of data obtained in a sequencing batch reactor are examined in light of the Activated Sludge Model No. 2. This model was calibrated using data from the first and second series working at low phosphorus concentrations. The Activated Sludge Model No. 2 successfully characterised the enhanced biological phosphorus removal performance of the sequencing batch reactor at low phosphorus concentrations. The calibrated model was then used to adjust experimental results of the other series working at high phosphor…
Estimation of Microbial Viability Using Flow Cytometry.
2020
For microorganisms in particular, viability is a term that is difficult to define and a state consequently difficult to measure. The traditional (and gold standard) usage equates viability and culturability (i.e., the ability to multiply) but the process of determining culturability is often too slow. Flow cytometry provides the opportunity to make rapid and quantitative measurements of dye uptake in large numbers of cells and we can therefore exploit the flow cytometric approach to evaluate so-called viability stains and to develop protocols for more routine assessments of microbial viability. This article provides a commentary and several protocols have been included to ensure that users …
Understanding the detector behavior through Montecarlo and calibration studies in view of the SOX measurement
2015
International audience; Borexino is an unsegmented neutrino detector operating at LNGS in central Italy. The experiment has shown its performances through its unprecedented accomplishments in the solar and geoneutrino detection. These performances make it an ideal tool to accomplish a state- of-the-art experiment able to test the existence of sterile neutrinos (SOX experiment). For both the solar and the SOX analysis, a good understanding of the detector response is fundamental. Consequently, calibration campaigns with radioactive sources have been performed over the years. The calibration data are of extreme importance to develop an accurate Monte Carlo code. This code is used in all the n…
An accurate optical technique for measuring the nuclear polarisation of 3He gas
2010
12 pages; International audience; In the metastability exchange optical pumping cells of our on-site production unit and of our other experimental set-ups, we use a light absorption technique to measure the 3He nuclear polarisation. It involves weak probe beams at 1083 nm, that are either perpendicular or parallel to the magnetic field and cell axis, with suitable light polarisations. When metastability exchange collisions control the populations of the sublevels in the 23S state, absolute values of the 3He ground state nuclear polarisation are directly inferred from the ratio of the absorption rates measured for these probe beams. Our report focuses on the transverse detection scheme for w…