Search results for "Calibration"

showing 10 items of 890 documents

Elastic wave propagation in bone in vivo: methodology.

1995

The purpose of this study was to investigate the usefulness of elastic wave propagation (EWP) in estimating the mechanical properties (elasticity) of human tibia. The test group was composed of 78-yr-old women assigned to high (n = 19) and low (n = 17) bone mineral density (BMD) groups as measured at the calcaneus by the 125I-photon absorption method. The EWP apparatus consisted of an impact-producing hammer with a force strain gauge and two accelerometers positioned on the bone. Results for nylon and acrylic were used to calibrate the apparatus. Polyvinyl chloride (PVC) solid rods and tubes of various diameters were used to evaluate the relationship between the elastic wave velocity and cr…

Materials scienceBone densityAccelerationTransducersBiomedical EngineeringBiophysicsAcrylic ResinsSecond moment of areaMineralogylaw.inventionFractures BonelawBone DensityAnimalsHumansOrthopedics and Sports MedicineHammerComposite materialElasticity (economics)Polyvinyl ChlorideStrain gaugeAgedBone mineralTibiaRehabilitationElasticityNylonsCalibrationCattleFemaleTomographyCalcaneusStress MechanicalTomography X-Ray ComputedAlgorithmsJournal of biomechanics
researchProduct

In-process calibration of a non-destructive testing system used for in-process inspection of multi-pass welding

2020

Abstract In multi-pass welding, there is increasing motivation to move towards in-process defect detection to enable real-time repair; thus avoiding deposition of more layers over a defective weld pass. All defect detection techniques require a consistent and repeatable approach to calibration to ensure that measured defect sizing is accurate. Conventional approaches to calibration employ fixed test blocks with known defect sizes, however, this methodology can lead to incorrect sizing when considering complex geometries, materials with challenging microstructure, and the significant thermal gradients present in materials during the inter-pass inspection period. To circumvent these challenge…

Materials scienceCalibration (statistics)TKMechanical engineering02 engineering and technologyWeldingIn-process calibration010402 general chemistry01 natural scienceslaw.inventionRobot weldingAcceptance testinglawNondestructive testinglcsh:TA401-492General Materials ScienceRobotic weldingIn-process welding and inspectionRobotic non-destructive testingbusiness.industryMechanical EngineeringProcess (computing)Phased array ultrasonic testing (PAUT)021001 nanoscience & nanotechnologyIntentionally embedded weld defectsSizing0104 chemical sciencesMechanics of Materialslcsh:Materials of engineering and construction. Mechanics of materialsUltrasonic sensor0210 nano-technologybusiness
researchProduct

Validation of a method for the determination of boron in ceramic materials by X-ray fluorescence spectrometry

2000

Abstract A method is proposed for boron determination in ceramic materials, boracic raw materials and ceramics frits of different compositions by wavelength dispersive X-ray fluorescence technique. The instrumental conditions were studied and the sample preparation procedures were optimized. The reference method used was the potentiometric titration of mannitol–boric complex acid and the technique was optimized for the determination of B 2 O 3 in each of the materials used. The samples for XRF determination were obtained as pellets and as glass discs. For the pellets different binders were studied, such as mannitol and cellullose for the samples of raw materials, and polyvinylpirrolidone an…

Materials scienceCalibration curvePotentiometric titrationAnalytical chemistryPelletschemistry.chemical_elementX-ray fluorescenceAtomic and Molecular Physics and OpticsAnalytical Chemistrychemistryvisual_artvisual_art.visual_art_mediumLithiumSample preparationCeramicBoronInstrumentationSpectroscopySpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Prediction of Tool Wear Progress in Machining of Carbon Steel using different Tool Wear Mechanismsl

2008

In this paper the prediction of tool wear on carbide uncoated tools was taken into account. In particular, two different tool wear models based on the diffusion mechanism and on the abrasion mechanism were considered. The calibration of the utilized models was done using the results obtained by experimental analysis performed on an orthogonally machined AISI 1020 tube. Once the calibration was executed, numerical simulations, for both the utilized tool wear models, were simultaneously performed with the aim to test the capability of the proposed numerical procedure. The comparison between the two tool wear mechanisms for predicting the flank tool wear is discussed in the paper.

Materials scienceCarbon steelMetallurgyMechanical engineeringengineering.materialFinite element methodtool wearAbrasion (geology)CarbideMachiningCalibrationengineeringGeneral Materials ScienceTool wearSettore ING-IND/16 - Tecnologie E Sistemi Di Lavorazionemechanisms and predictionInternational Journal of Material Forming
researchProduct

Numerical simulations of the mechanical characteristics of glass fibre reinforced C-profiles

2006

A mechanical characterisation analysis on pultruded glass fibre reinforced C-shaped profiles, developed as modular construction elements to assemble fastening systems, such as doors, window frames and shutters is presented. The key idea is to perform the analysis, and all the related identification procedures of the material parameters, via a coupled approach, based on a limited number of standard laboratory tests and on the numerical finite element simulations of the same tests. The proposed approach allows one to identify all those material parameters which are difficult to detect, by means of simple laboratory experiments on specimens that are extracted from commercial products. It also …

Materials scienceComputer simulationDesign toolGlass fiberGeneral EngineeringE. Pultrusion.Modular constructionA. Polymer–matrix compositeFinite element methodSimple (abstract algebra)PultrusionCeramics and CompositesCalibrationComposite materialB. Mechanical characterisation C. Finite element modelling
researchProduct

Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy

2020

GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a "fogging" effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.

Materials scienceDosimeterFoggingbusiness.industryCalibration curveSettore ING-IND/20 - Misure E Strumentazione Nuclearimedicine.medical_treatmentBrachytherapydosimetry GAFChromic film gamma radiation radiotherapy030218 nuclear medicine & medical imagingRadiation therapy03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed dosemedicineDosimetrybusinessQuality assuranceBiomedical engineering
researchProduct

Influence of the simultaneous calibration of multiple ring dosimeters on the individual absorbed dose

2021

Abstract Ring dosimeters for personal dosimetry are calibrated in accredited laboratories following ISO 4037-3 guidelines. The simultaneous irradiation of multiple dosimeters would save time, but has to be carefully studied, since the scattering conditions could change and influence the absorbed dose in nearby dosimeters. Monte Carlo simulations using PENELOPE-2014 were performed to explore the need to increase the uncertainty of H p 0 .07 in the simultaneous irradiation of three and five DXT-RAD 707H-2 (Thermo Scientific) ring dosimeters with beam qualities: N-30, N-80 and N-300. Results show that the absorbed dose in each dosimeter is compatible with each of the others and with the refere…

Materials scienceDosimeterRadiation Dosimetersbusiness.industryMonte Carlo methodPublic Health Environmental and Occupational HealthCoverage probabilityGeneral Medicine030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptics030220 oncology & carcinogenesisAbsorbed doseCalibrationCalibrationDosimetryComputer SimulationIrradiationRadiometryCalibration ISO 4037 Monte Carlo Personal dosimetry Ring dosimetersbusinessMonte Carlo MethodWaste Management and DisposalBeam (structure)Journal of Radiological Protection
researchProduct

Design and evaluation of a HDR skin applicator with flattening filter

2008

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…

Materials scienceDosimeterbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomKermaOpticsIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

Local Reinforcement Effect of a Strain Gauge Installation on Low Modulus Materials

2005

The reinforcement effect of electrical resistance strain gauges is well documented in the technical literature. In this paper the local reinforcement effect in tension is studied by using a simple theoretical model by considering a strain gauge mounted on a semi-infinite plate having the same width of the strain gauge and subjected to a uniaxial tension load. Neglecting the effect of the adhesive layer and considering the interface shear stress as an exponential distribution, the proposed model gives a closed-form solution. In detail, this model permits a simple formula to be obtained which allows the user to correct the local reinforcement effect provided that a proper calibration is perfo…

Materials scienceExponential distributionbusiness.industryTension (physics)Applied MathematicsMechanical EngineeringStructural engineeringElectrical resistance and conductanceMechanics of MaterialsModeling and SimulationShear stressCalibrationAdhesivebusinessReinforcementStrain gaugeThe Journal of Strain Analysis for Engineering Design
researchProduct

LABORATORY INSTRUMENTATION TO STUDY CHANGES OF ELECTRICAL CONDUCTIVITY OF ROCKS WITH CHANGES OF FREQUENCY, TEMPERATURE AND PRESSURE*

1983

A laboratory instrument was developed to investigate the electrical properties of rock samples with respect to changes of frequency, temperature and pressure. The instrument can be used to obtain general trends and typical values for geological media. It should be of particular interest in geothermal studies and research in the geophysical properties of rocks. The design intervals for quantities under investigation were 20–300°C, 10 5 -4 × 10 7 Pa and 5 × 10 −4 -10 3 Hz. Certain limitations exist on the simultaneous use of the highest values of temperature and pressure. The main features of the instrument are: analog electrical outputs recorded by an x-y recorder or observed on a scope with…

Materials scienceHydrogeologyInstrumentationGeneral EngineeringMineralogyPressure vesselTemperature and pressureGeophysicsGeochemistry and PetrologyElectrical resistivity and conductivityCalibrationGeotechnical engineeringInstrumentation (computer programming)Hydraulic machineryGeothermal gradientIgneous petrologyGeologyGeophysical Prospecting
researchProduct