Search results for "Calibration"
showing 10 items of 890 documents
Water desalination by capacitive electrodialysis: Experiments and modelling
2020
Abstract Electrodialysis-related technologies keep spreading in multiple fields, among which water desalination still plays a major role. A new technology that has not yet been thoroughly investigated is capacitive electrodialysis (CED), which couples the standard ED with capacitive electrodes. CED has a number of advantages such as removal of toxic products and system simplification. Little mention is made of this technology in the literature and, to the best of our knowledge, no modelling works have ever been presented. In this work, the CED process has been studied through experiments and modelling. A CED model is presented for the first time. With a simple calibration based on macroscop…
Experiences with CiceRobot, a Museum Guide Cognitive Robot
2005
The paper describes CiceRobot, a robot based on a cognitive architecture for robot vision and action. The aim of the architecture is to integrate visual perception and actions with knowledge representation, in order to let the robot to generate a deep inner understanding of its environment. The principled integration of perception, action and of symbolic knowledge is based on the introduction of an intermediate representation based on Gardenfors conceptual spaces. The architecture has been tested on a RWI B21 autonomous robot on tasks related with guided tours in the Archaeological Museum of Agrigento. Experimental results are presented.
Field run-up measurements: Calibration of a physically based lagrangian shoreline model
2012
In the present contribution a measurement technique based on video imaging has been selected for the assessment of the maximum run-up. Such measurements have been used for the calibration of a numerical model and of an empirical formulation. The on-site run-up measurements have been carried out at “Lido Signorino” beach, near Marsala, Italy. The positions of the swash have been localized on a transect, normal to the shore, constituted by stakes placed at 0.5 m intervals each other. The video camera was placed orthogonally to the line of the stakes. For the numerical simulations a 1DH Boussinesq-type of model for breaking waves has been applied which takes into account the wave run-up by a L…
Generation of multidimensional random pulses for radioactivity measurements
2000
Multidimensional binary pseudo-random pulses are extremely useful for the set-up calibration and testing of radioactivity measuring equipment. A new method of generation of such signals, based on the parting operation of labeled pulse trains, is presented. The concept of a general coincidence ratio is introduced. Digital window comparators and prohibited or permitted state programmers capable of performing the parting operation and controlling the values of the coincidence ratio are proposed.
Quantitative thermoelastic stress analysis by means of low-cost setups
2020
Abstract A low-cost Thermoelastic Stress Analysis (TSA) experimental setup is proposed which uses an ordinary micro-bolometer and in-house developed signal processing scripts. The setup is evaluated by analysing the thermoelastic signal from a tensile and a SENT specimen made of stainless steel AISI 304L, and the bolometer performances are compared with those of a state of the art photon detector. Signal processing is based on off-line cross-correlation, using a self-reference signal which is retrieved from the acquired thermal data. Procedures are in particular developed to recognise, quantify and correct errors due to spectral leakage and loss of streamed frames. The thermoelastic signal …
Numerical Calibration of a Simplified Model for FRP Confinement of Columns
2018
This paper presents the calibration of a simplified analytical model for concrete columns confined by fiber reinforced polymer (FRP) jackets. The model allows evaluating the increase of strength, ductility and dissipated energy without defining the lateral confinement pressure and it can be easily extended for the assessment of FRP confinement in design applications. This model was obtained by a simplified procedure based on the best fit of experimental data available in the literature and the coefficient of determination (R2) was evaluated in order to estimate the accuracy of the regression analysis. A numerical database resulting from finite element (FE) analyses was compiled and reported…
Calibration of the SARI portable rainfall simulator for field and laboratory experiments
2019
The Simulator of Artificial RaInfall (SARI) rainfall simulator (RS) is a newly designed, constructed and calibrated, portable, two-nozzle RS with low water consumption, accurate measurement, easy m...
Accuracy of an Affordable Smartphone-Based Teledermoscopy System for Color Measurements in Canine Skin
2020
Quality smartphone cameras and affordable dermatoscopes have enabled teledermoscopy to become a popular medical and veterinary tool for analyzing skin lesions such as melanoma and erythema. However, smartphones acquire images in an unknown RGB color space, which prevents a standardized colorimetric skin analysis. In this work, we supplemented a typical veterinary teledermoscopy system with a conventional color calibration procedure, and we studied two mid-priced smartphones in evaluating native and erythematous canine skin color. In a laboratory setting with the ColorChecker, the teledermoscopy system reached CIELAB-based color differences &Delta
Advances in designing drip irrigation laterals
2018
It is known that using paired laterals, in which two distribution pipes extend in opposite directions from a common manifold, contribute to increasing water use efficiency (WUE). Recently, an analytical procedure to optimally design paired drip laterals on uniform slopes was proposed. More recently, this design procedure was simplified by deriving simple explicit relationships, as a function of 16 calibration constants, with relative errors that were less than 2%. In this paper, further simple design relationships are derived that require only 3 calibration constants, thus more readily obtainable results are produced and the influence of the flow rate and diameter exponents of resistance eq…
Physiological HEPES Buffer Proposed as a Calibrator for pH Measurement in Human Blood
1999
Abstract N-(2-hydroxyethyl)-piperazine-N'-2-ethanesulfonic acid, known as HEPES buffer, with p K in the physiological range was studied for use as an alternative to conventional phosphate buffer for the calibration of pH in modern clinical analyzers. In different series of aqueous equimolar HEPES buffer, pH was measured at 37 °C with a capillary glass electrode standardized previously using phosphate, and variations due to changes in total HEPES buffer concentration (0.025 to 0.320 mol/l), and NaCl (0 to 0.250 mol/l) were monitored. For 0.05 equimolar HEPES buffer without NaCl, the pH of 7.362 ± 0.003 (n = 15) obtained coincided well with the reference pH (7.364) from the National Institute…