Search results for "Cardiac"
showing 10 items of 1495 documents
Wireless ECG and cardiac monitoring systems: State of the art, available commercial devices and useful electronic components
2021
Abstract Wireless ElectroCardioGram (ECG) systems are employed in manifold application fields: tele-monitoring, sport applications, support to ageing people at home, fetal ECG, wearable devices and ambulatory monitoring. The presence of cables often hinders user’s free movements, alongside clinicians’ routine operations. Therefore, wireless ECG systems are desirable. This paper aims at reviewing the solutions described in the literature, besides commercially available devices and electronic components useful to setup laboratory prototypes. Several systems have been developed, different in terms of the adopted technology; when approaching the development of a wireless ECG system, some import…
Congenital mitral regurgitation caused by a perforation in the anterior leaflet: Perioperative evaluation by color-coded Doppler echocardiography
1990
Color-coded two-dimensional (2D) echocardiography confirmed the presence of severe congenital mitral regurgitation in an 8-month-old infant. Intraoperative inspection revealed an isolated perforation in the anterior leaflet.
Combined approach to atrial and ventricular function for assessment of diastole through MRI: Hypertrophic Cardiomyopathy (HCM) vs Healthy Controls (H…
2013
Purpose Methods and Materials Results Conclusion References Personal Information
Graph cut-based method for segmenting the left ventricle from MRI or echocardiographic images
2017
International audience; In this paper, we present a fast and interactive graph cut method for 3D segmentation of the endocardial wall of the left ventricle (LV) adapted to work on two of the most widely used modalities: magnetic resonance imaging (MRI) and echocardiography. Our method accounts for the fundamentally different nature of both modalities: 3D echocardiographic images have a low contrast, a poor signal-to-noise ratio and frequent signal drop, while MR images are more detailed but also cluttered and contain highly anisotropic voxels. The main characteristic of our method is to work in a 3D Bezier coordinate system instead of the original Euclidean space. This comes with several ad…
Cardiac threat appraisal and depression after first myocardial infarction
2012
The present study investigated cardiac threat appraisal and its association with depression after first myocardial infarction (MI). A semi-structured interview allowing for DSM-IV-Axis I diagnoses was administered to 36 patients after first MI. Patients completed self-reports 5 to 15 days after the MI (time 1), 6 to 8 weeks later (time 2) and again 6 months later (time 3). Assessments at time 1 included indices of cardiac threat appraisal, locus of control, coping, and depression while at time 2 and time 3 only measures of depression were obtained. Cardiac threat appraisal was significantly correlated with depression at time 1, but was unrelated to depression scores at time 2 and time 3. Fu…
Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary …
2009
This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (> or =16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off…
Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography
2008
The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 +/- 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 +/- 55 mm. The intermediate branch was present in the 21.9%. A variable number …
Klotho urinario determinado por ELISA como biomarcador precoz de fracaso renal agudo en pacientes sometidos a cirugía cardiaca o angiografía coronaria
2015
ResumenIntroducción y objetivos: El fracaso renal agudo (FRA) es una complicación frecuente tras la cirugía cardiaca y las intervenciones percutáneas coronarias cuya aparición empeora el pronóstico de manera marcada. En los últimos años se han identificado nuevos biomarcadores precoces de FRA, pero aún quedan muchos aspectos importantes por resolver. Klotho es una proteína pleiotrópica que actúa como un factor paracrino y endocrino en múltiples órganos. En diversos modelos animales de FRA se ha demostrado niveles disminuidos de Klotho renal. No se ha publicado ningún estudio en el que se haya probado Klotho como marcador precoz de FRA en humanos. El objetivo de este trabajo es investigar la…
Diagnóstico etilógico de la disfunción ventricular izquierda con tomografia computerizada: comparación con coronariografía y cardiorresonancia
2012
[EN] Introduction and objectives To evaluate the capability of multidetector computed tomography to diagnose the coronary etiology of left ventricular dysfunction compared with using invasive coronary angiography and magnetic resonance. Methods Forty consecutive patients with left ventricular dysfunction of uncertain etiology underwent invasive coronary angiography and contrast magnetic resonance. All patients were evaluated with multidetector computed tomography including coronary calcium presence and score, noninvasive coronary angiography, and myocardial tissue assessment. Results The sensitivity and specificity of the presence of coronary calcium to identify left ventricular dysfunction…
Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing
2006
OBJECTIVE. The objective of our study was to compare diagnostic accuracy of MDCT coronary angiography in a population of patients with mild heart rhythm irregularities before and after editing the ECG. SUBJECTS AND METHODS. Thirty-eight patients who underwent MDCT coronary angiography and conventional coronary angiography were enrolled in the study. The inclusion criterion was the presence of mild heart rhythm irregularities (i.e., premature beats; atrial fibrillation; mistriggering; or low heart rate, defined as 40 beats per minute or less) during the scan. All patients underwent MDCT with the following parameters: 16 detectors; collimation, 0.75 mm; gantry rotation time, 375 msec; 120 kV;…