Search results for "Cartridge"
showing 10 items of 20 documents
Flow injection Fourier transform infrared determination of caffeine in coffee
1999
Abstract A fully automatized procedure has been developed for the Fourier transform infrared (FT-IR) spectroscopic determination of caffeine in coffee samples. The method involves the on-line extraction of caffeine with CHCl3. Samples, weighed inside empty PTFE cartridges of 0.5 cm internal diameter (i.d.) and 1.5 ml volume, were humidified with four drops of 0.25 M NH3. The cartridge was installed in a flow manifold, in which samples were extracted in a closed-flow system with 1 ml CHCl3 during 6 min. Four hundred microliters of the extract were introduced in a microflow cell and absorbance measured as a function of time at 1659 cm−1, with a baseline established between 1900 and 830 cm−1, …
Calibration of LA-ICP-MS via standard addition using dried picoliter droplets
2020
A novel microanalytical calibration approach for quantitative spatially resolved analysis of thin layered materials with laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is presented. This method relies on standard addition via the generation of dried pL-droplet residues. Therefore, a drop on demand dosing device based on a modified commercial ink cartridge and a dosing interface, both accessible via a self-constructed microcontroller, were developed. This dosing device enables the precise deposition of pL-droplets onto solid samples for the generation of residues with dimensions in the low μm-range. The LA-ICP-MS analysis of such residues allows calibration over at l…
A method for the determination of dimethylamine in air by collection on solid support sorbent with subsequent derivatization and spectrophotometric a…
2005
A new method for dimethylamine determination in air is reported. The proposed assay is based on the employment of C18-packed solid phase extraction cartridges for sampling. The retained amine is then derivatized inside the cartridges with the reagent 1,2-naphthoquinone-4-sulfonate. By observing the coloured area of the cartridge, a semiquantitative estimation of the amine can be made. It was also possible to distinguish between primary and secondary amines by visual inspection. Quantitative tests entailed desorption from the cartridges of the derivatives formed, and measurement of the absorbance of the collected extracts. The selected conditions were applied to quantify dimethylamine up to …
Sample Preparation to Determine Pharmaceutical and Personal Care Products in an All-Water Matrix: Solid Phase Extraction
2020
© 2020 by the authors. Pharmaceuticals and personal care products (PPCPs) are abundantly used by people, and some of them are excreted unaltered or as metabolites through urine, with the sewage being the most important source to their release to the environment. These compounds are in almost all types of water (wastewater, surface water, groundwater, etc.) at concentrations ranging from ng/L to µg/L. The isolation and concentration of the PPCPs from water achieves the appropriate sensitivity. This step is mostly based on solid-phase extraction (SPE) but also includes other approaches (dispersive liquid-liquid microextraction (DLLME), buckypaper, SPE using multicartridges, etc.). In this rev…
Polymeric monolithic microcartridges with gold nanoparticles for the analysis of protein biomarkers by on-line solid-phase extraction capillary elect…
2020
In this study, polymeric monoliths with gold nanoparticles (AuNP@monolith) were investigated as microcartridges for the analysis of protein biomarkers by on-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS). “Plug-and-play” microcartridges (7 mm) were prepared from a glycidyl methacrylate (GMA)-based monolithic capillary column (5 cm x 250 µm i.d.), which was modified with ammonia and subsequently functionalized with gold nanoparticles (AuNPs). The performance of these novel microcartridges was evaluated with human transthyretin (TTR), which is a protein related to different types of familial amyloidotic polyneuropathies (FAP). Protein retention depended on…
Metal pins fired from unmodified blank cartridge guns and very small calibre weapons - technical and wound ballistic aspects
1998
Blank cartridge guns are generally regarded as being harmless and are not considered to be firearms in most countries. A comparison of the legal situations in Germany and Austria concerning weapons is given. There have been several reports of serious injuries and even fatalities due to these weapons. Ballistic experiments show that even unmodified blank cartridge guns and very small calibre weapons can fire wire nails and can inflict potentially fatal injuries even at distances of 50 cm. Two serious injuries inflicted by metal pins fired from a blank cartridge gun and a very small calibre weapon are reported. These cases suggest that such weapons should also be considered handguns in the le…
Analysis of primary aliphatic short-chain monoamines by LC in water samples
2003
Abstract Several derivatization procedures with o-phthaldialdehyde-N-acetylcysteine (OPA-NAC) were compared for a rapid analysis of primary aliphatic short-chain monoamines in water samples by HPLC using a LiChorospher analytical separation column (100RP18 125 mm ×4 mm i.d., 5 μm). Both the solution and the solid-support assisted off-line derivatization on C18 SPE cartridges were inadequate options because of beginning degradation processes of the instable isoindol derivatives during their transfer to the analytical column. This problem was precluded with the on-column or solid-support assisted on-line derivatization. In the last mentioned procedure, the derivatization took place in a Hype…
Separation of polycyclic aromatic hydrocarbons under isocratic conditions by a column switching technique
1994
A simple and efficient method of separating a 20-component PAH-mixture (RSM 1647 standard mixture +benzene, toluene, perylene and coronene) by RP-HPLC is described. Separation was by using two Superspher-100 RP-18 cartridges thermostatted at different temperatures under isocratic conditions with water-acetonitrile eluent. The analysis time with complete resolution of all components can be reduced to 15 min.
Use of reversed-phase C18 Sep-Pak cartridges for the purification and concentration of sepiapterin and other pteridines
1985
Abstract Several pteridines have been tested for their ability to bind to C 18 Sep-Pak. Riboflavin, sepiapterin, deoxysepiapterin, 6-acetyl-7,8-dihydropterin, 6-acetyldihydrohomopterin and 3′-hydroxysepiapterin were strongly retained and all but 6-acetyldihydrohomopterin quantitatively recovered upon elution with 2 ml of methanol. The effect of the concentration and volume of the sample, pH and salt concentration on the retention of sepiapterin have been studied. The procedure was very useful for the purification, desalting, solvent exchange and concentration of pteridines having high affinity for the cartridge. C 18 Sep-Pak has been applied succesfully to sample clean-up prior to high-perf…
Post-Processing via Cation Exchange Cartridges: Versatile Options
2012
New 68Ge/68Ga radionuclide generators provide the positron emitter 68Ga (T½ = 67.7 min) as an easily available and relatively inexpensive source of a PET nuclide for labeling of interesting targeting vectors. However, currently available “ionic” 68Ge/68Ga radionuclide generators are not necessarily optimized for the routine synthesis of 68Ga-labeled radiopharmaceuticals in a clinical environment. Post-processing of 68Ge/68Ga generators using cation exchange resins provides chemically and radiochemically pure 68Ga with 97±2% within less than 4 min, with 68Ge almost completely removed, and ready for online labeling. This simple, fast, and efficient technology can be extended for new applicati…