Search results for "Cataract Surgery"

showing 10 items of 82 documents

Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity

2008

A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in the right eye was significantly higher than that in the left eye (+0.112 microm +/- 0.002 [SD] versus +0.021 +/- 0.003 microm; P.001). No between-eye difference in the best corrected visual acuity and photopic contrast sensitivity was found. The contrast sensitivity was significantly better in the eye with the AcrySof IQ IOL at 12 and 18 cpd under mesopic conditions. The best c…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensPupilContrast SensitivityCorneaLens Implantation IntraocularOphthalmologyCorneamedicineHumansContrast (vision)media_commonPhacoemulsificationbusiness.industryMiddle AgedCataract surgeryRefractive Errorseye diseasesSensory SystemsOphthalmologyLeft eyeSpherical aberrationmedicine.anatomical_structureSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Axial Elongation following Cataract Surgery during the First Year of Life in the Infant Aphakia Treatment Study

2012

PURPOSE To compare ocular axial elongation in infants after unilateral cataract surgery corrected with a contact lens (CL) or primary intraocular lens (IOL) implantation. METHODS Baseline axial length (AL) was measured at the time of cataract surgery (1-6 months) and at age 1 year. AL at baseline and age 1 year and the change in length/mo were analyzed in relation to treatment modality, cataractous versus fellow eye, and age at surgery using linear mixed models. RESULTS Mean baseline AL did not differ between the CL and IOL groups for either cataractous or fellow eyes. Eyes with cataracts were shorter than fellow eyes by an average of 0.6 mm (95% confidence interval [CI], 0.4-0.8 mm; P < 0.…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedicine.medical_treatmentVisual AcuityIntraocular lensFirst year of lifeAphakia PostcataractCataract ExtractionAphakiaCataractCataractsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryInfant NewbornInfantArticlesCataract surgerymedicine.diseaseRefractive ErrorsAxial elongationeye diseasesSurgeryContact lensTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up Studies
researchProduct

The combination of diffractive and refractive multifocal intraocular lenses to provide full visual function after cataract surgery.

2009

PURPOSE To investigate if implantation of a far dominant refractive multifocal intraocular lens (IOL) in one eye and a near dominant diffractive multifocal IOL in the fellow eye improves range of vision following cataract surgery. METHODS This was a prospective, nonrandomized, case-control study involving 20 patients (40 eyes) scheduled for cataract surgery. Inclusion criteria were bilateral cataracts, minimum age 50 years, availability for follow-up visits, and informed consent. All patients received a far dominant refractive multifocal IOL (ReZoom, Abbott Medical Optics) in their dominant eye and a near dominant diffractive multifocal IOL (Tecnis ZM900, AMO) in their nondominant eye. Preo…

Malemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityAfter cataractProsthesis DesignRefraction OcularOcular dominance03 medical and health sciences0302 clinical medicineOphthalmologyMedicineHumansPostoperative PeriodProspective StudiesAgedAged 80 and overLenses IntraocularVision Binocularbusiness.industryGeneral MedicineMultifocal intraocular lensCataract surgeryMiddle AgedRefractioneye diseasesBilateral CataractsOphthalmologyVisual functionCase-Control Studies030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up StudiesEuropean journal of ophthalmology
researchProduct

Efficacy and Safety of Mass Cataract Surgery Campaign in a Developing Country

2012

To determine the visual outcomes achieved in terms of efficacy and safety during a mass eye surgery campaign in a low-income developing country.Three hundred fifteen eyes of 305 patients underwent extracapsular cataract extraction with intraocular lens implantation in a prospective, analytical, experimental, and nonrandomized study on patients who underwent cataract surgery during the campaign that two Spanish nongovernmental organizations conducted in December 2008 in a district hospital in Bobo-Dioulasso (Burkina Faso).Mean age was 61.97 ± 14.39 years. The mean uncorrected distance visual acuity before surgery was 2.17 ± 0.7 (20/3000), which improved to 0.86 ± 0.64 logMAR (20/150) 3 month…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityDeveloping countryIntraocular lensCataract ExtractionCataractCataract extractionLens Implantation IntraocularBurkina FasomedicineHumansProspective StudiesEye surgeryProspective cohort studyDeveloping Countriesbusiness.industryFollow up studiesMiddle AgedCataract surgeryeye diseasesSurgeryOphthalmologyTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Visual outcomes and complications of congenital cataract surgery

2019

Corresponding author at: Department of Ophthalmology, 14, rue Paul-Gaffarel, 21000 Dijon, France. This work is issued from the oral presentation during the 123rd congress of the French Ophthalmological Society.; International audience; PURPOSE: To describe the visual results and postoperative complications of congenital cataract surgeries performed between 2005 and 2016. METHODS: A retrospective consecutive case series of congenital cataract surgeries was carried out at the Dijon University Hospital in France. Intraocular lens implantation was primary or secondary according to age. Pre- and post-operative assessment was performed through ophthalmologic consultations with orthoptic measureme…

Malemedicine.medical_specialtyVisual acuitygenetic structuresvisual acuitymedicine.medical_treatmentintraocular lensIntraocular lensCataract ExtractionCataract03 medical and health sciences0302 clinical medicineLens Implantation IntraocularCataractsInterquartile rangepostoperative complicationsHumansMedicine[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansRetrospective StudiesLenses Intraocularbusiness.industryInfantPostoperative complicationConsecutive case seriesCataract surgerymedicine.diseaseeye diseases3. Good healthSurgeryBilateral CataractsOphthalmologyTreatment Outcomecongenital cataractChild Preschool030221 ophthalmology & optometryFemaleFrancesense organsmedicine.symptombusiness[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

ReSTOR® Diffractive versus Array®2 Zonal-progressive Multifocal Intraocular Lens: a Contralateral Comparison

2007

PURPOSE. To evaluate near and distance visual performance after implantation of a diffractive multifocal intraocular lens (MIOL) (AcrySof ReSTOR ® ) or a refractive MIOL (Array ® 2) in bilateral cataract surgery. METHODS. In this prospective, comparative trial, 18 patients with bilateral cataract were selected to have lens surgery with asymmetric MIOL implantation. Eighteen eyes received ReSTOR MIOL and the 18 fellow eyes were implanted with Array 2. Five months after second lens implantation, main postoperative outcomes were uncorrected and distance corrected near visual acuities (VA). Secondary outcomes were distance VA and near acuity with power add, contrast sensitivity with and without…

Malemedicine.medical_specialtygenetic structuresSubjective ratingmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction Ocular03 medical and health sciences0302 clinical medicineNear acuityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryGlare (vision)PresbyopiaGeneral MedicineCataract surgeryMultifocal intraocular lenseye diseasesOphthalmologyTreatment Outcomemedicine.anatomical_structurePatient SatisfactionGlare disabilityLens (anatomy)030221 ophthalmology & optometryOptometryFemalesense organsbusiness030217 neurology & neurosurgeryFollow-Up StudiesEuropean Journal of Ophthalmology
researchProduct

Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation

2003

Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…

Malemedicine.medical_specialtymedicine.medical_treatmentAcrylic ResinsLens Capsule CrystallineIntraocular lensPositive correlationCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageLenses IntraocularPhacoemulsificationbusiness.industryCapsulePhacoemulsificationCataract surgeryCapsulorhexisSensory SystemsOphthalmologyCapsular bagFemaleSurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

2005

To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…

Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessJournal of cataract and refractive surgery
researchProduct

Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…

2021

Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…

Medicine (General)medicine.medical_specialtyIntraocular Lens Dislocationgenetic structuresmedicine.medical_treatmentIntraocular lensAfter cataractArticleCataractlate intraocular lens dislocationR5-920Postoperative ComplicationsLens Implantation IntraocularmedicineHumansProspective StudiesProspective cohort studyweak zonules; anterior capsule opening reduction; late intraocular lens dislocation; capsular tension ringReduction (orthopedic surgery)Lenses IntraocularPhacoemulsificationbusiness.industryweak zonulescapsular tension ringGeneral MedicinePhacoemulsificationCataract surgeryLens Subluxationmedicine.diseaseComorbidityeye diseasesSurgeryanterior capsule opening reductionsense organsbusinessMedicina
researchProduct

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

2015

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

Optics and PhotonicsOptical PhenomenaComputer sciencemedicine.medical_treatmentCataract ExtractionProsthesis DesignRefraction Ocular03 medical and health sciencesNear vision0302 clinical medicineLens Implantation IntraocularOptical transfer functionmedicineProsthesis designHumansLenses IntraocularStrehl ratioCataract surgeryMultifocal intraocular lensModels TheoreticalSensory SystemsOptical qualityOphthalmologyIntraocular lenses030221 ophthalmology & optometryOptometrySurgery030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct