Search results for "Cataract"
showing 10 items of 195 documents
ReSTOR® Diffractive versus Array®2 Zonal-progressive Multifocal Intraocular Lens: a Contralateral Comparison
2007
PURPOSE. To evaluate near and distance visual performance after implantation of a diffractive multifocal intraocular lens (MIOL) (AcrySof ReSTOR ® ) or a refractive MIOL (Array ® 2) in bilateral cataract surgery. METHODS. In this prospective, comparative trial, 18 patients with bilateral cataract were selected to have lens surgery with asymmetric MIOL implantation. Eighteen eyes received ReSTOR MIOL and the 18 fellow eyes were implanted with Array 2. Five months after second lens implantation, main postoperative outcomes were uncorrected and distance corrected near visual acuities (VA). Secondary outcomes were distance VA and near acuity with power add, contrast sensitivity with and without…
Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.
2011
Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…
Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation
2003
Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…
Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…
2021
Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…
Folding and stability of the aquaglyceroporin GlpF: Implications for human aqua(glycero)porin diseases
2015
AbstractAquaporins are highly selective polytopic transmembrane channel proteins that facilitate the permeation of water across cellular membranes in a large diversity of organisms. Defects in aquaporin function are associated with common diseases, such as nephrogenic diabetes insipidus, congenital cataract and certain types of cancer. In general, aquaporins have a highly conserved structure; from prokaryotes to humans. The conserved structure, together with structural dynamics and the structural framework for substrate selectivity is discussed. The folding pathway of aquaporins has been a topic of several studies in recent years. These studies revealed that a conserved protein structure ca…
Caractérisation des effets ophtalmiques du syndrome de Cohen chez des souris VPS13B-/- et identification des mécanismes moléculaires impliqué dans la…
2020
Cohen Syndrome (CS) is a rare autosomal recessive disease caused by variations in the gene coding for the vacuolar tri-vacuolar protein 13B (VPS13B or COH1). CS patients have common features including typical facial appearance, neutropenia, abnormal trunk fat distribution, microcephaly, myopia and retinal damage. My thesis project aimed to characterize the ophthalmologic phenotype of a mouse model Vps13bEx3/Ex3 to determine the molecular mechanisms involved in the development of CS retinopathy.First, we showed that Vps13bEx3/Ex3 mice develop a cataract between 2 and 3 months. Disorganization of the fibrous cells of the crystalline lens and their differentiation into mesenchymal cells were o…
Comfort visivo e indipendenza da occhiali con IOLs multifocali di nuova generazione: follow-up a 1 anno
2008
Marinesco-Sjögren syndrome caused by a new SIL1 frameshift mutation
2015
no abstract available
In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.
2015
Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…