Search results for "Cataract"
showing 10 items of 195 documents
The association between diabetes and cataract among 42,469 community-dwelling adults in six low- and middle-income countries
2018
Background: Cataract is a major cause of visual impairment in people with diabetes, yet a paucity of data is available in low- and middle-income countries (LMICs) on this comorbidity. Thus we assessed the association between diabetes and cataract in 6 LMICs. Methods: Cross-sectional, community-based data from the Study on Global Ageing and Adult Health (SAGE) was analyzed (n = 42,469 aged ≥18 years). Five years information on self-reported diagnosis of cataract was collected. Three definitions for cataract were used: (a) Self-reported diagnosis and/or past 12-month symptoms; (b) Solely self-reported diagnosis; and (c) Surgical treatment for cataract in the past five years. Diabetes was base…
Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.
2015
Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…
Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism
2015
Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…
Rate of Cataract Formation in 343 Highly Myopic Eyes After Implantation of Three Types of Phakic Intraocular Lenses
2004
ABSTRACT PURPOSE: To assess the feasibility of using phakic intraocular lenses (PIOL) to treat high myopia, and evaluate the incidence of cataract, comparing three different lens types. METHODS: From 1989 to 2002, we implanted three different phakic intraocular lenses (PIOL) in 343 eyes of 232 patients; 231 eyes recieved an Ophtec (Worst-Fechner model, iris-claw), 89 an Adatomed (silicone posterior chamber), and 23 a Staar (posterior chamber, models V2, V3, V4). Average follow-up was 96.2 months for the Ophtec group, 31.5 months for the Adatomed group, and 19.3 months for Staar group. Eyes that subsequently developed cataract were studied for clinical evolution and had PIOL explantation and…
Phakic intraocular lenses to correct high myopia
2003
Abstract Purpose: To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. Setting: La Fe University Hospital, Department of Ophthalmology, and the Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods: In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was −15.39 diopters (D) ± 2.83 (SD), −16.00 ± 5.05 D, and −16.17 ± 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The …
Prevalence of corneal astigmatism before cataract surgery.
2008
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…
Immunohistochemical analysis of cellular adhesion molecules (ICAM-1, VCAM-1) and VEGF in fibrovascular membranes of patients with proliferative diabe…
2009
Abstract Purpose Diabetic fibrovascular membranes are the main pathological changes of proliferative diabetic retinopathy that can cause serious complications leading to blindness. Since the mechanism of fibrovascular membrane development is still unknown, the aim of our study was to identify potential biomarkers for this pathology. To this end, we analyzed the simultaneous expression of ICAM-1, VCAM-1 and VEGF within tissues of diabetic fibrovascular membranes. Patients and methods Fibrovascular membranes were taken from nine diabetic patients with proliferative diabetic retinopathy. The fibrovascular membrane specimens were analyzed by immunohistochemistry to determine ICAM-1, VCAM-1 and …
Aqueous Humor Levels of Vascular Endothelial Growth Factor in Retinitis Pigmentosa
2008
PURPOSE To determine the level of vascular endothelial growth factor A (VEGF-A) in aqueous humors of patients with retinitis pigmentosa (RP). METHODS A prospective, comparative control study. Aqueous humor was collected from 16 eyes of 16 patients with RP. The level of VEGF-A was determined with a commercially available enzyme-linked immunosorbent assay kit. The control group comprised 16 aqueous samples from 16 patients about to undergo cataract surgery and without any other ocular or systemic diseases. RESULTS The concentration of VEGF-A in aqueous humor was markedly lower in patients with RP than in control subjects (Mann-Whitney U test, P < 0.001). The level of VEGF-A was 94.9 +/- 99.8 …
Methodological Aspects of the Application of the Naka-Rushton Equation to Clinical Electroretinogram
1993
The nonlinear relation between stimulus intensity and response amplitude of the electroretinogram (ERG) scotopic b wave can be described by a curve based on the Naka-Rushton (NR) equation. Up to now, the NR equation has been used to assess the features of the normal and pathological ERG, but the best approach for a correct evaluation of the parameters is still debatable. The parameters are thought to be related to the different conditions of retinal activities. The method is well known in experimental laboratories but is quite unusual at the clinical level. In the present paper the derivative analysis of the NR function is proposed as an easier approach to understand the variations of the N…
Associations between cataract and multimorbidity: a cross-sectional study of 23,089 adults from Spain
2020
Background: Little is known about the association between cataract and multimorbidity. Therefore, the aim of the present study was to examine the relationship between cataract and chronic conditions and multimorbidity in a large representative sample of Spanish adults. Methods: This study used data from the Spanish National Health Survey 2017, a cross-sectional sample of 23,089 adults aged ≥15 years from Spain [54.1% female; mean (standard deviation) age 53.4 (18.9) years]. Cataract and 30 other physical and mental chronic conditions were self-reported. Multimorbidity was defined as the presence of at least two physical and/or mental chronic conditions (excluding cataract). Control variable…