Search results for "Cements"
showing 10 items of 136 documents
Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses
2017
The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…
Retentive strengths of cast gold crowns using glass ionomer, compomer, or resin cement
1998
The retention forces of a newly developed compomer cement (Dyract Cem), a glass ionomer cement (Ketac Cem Aplicap), and a resin cement (F21) were examined.Cemented cast gold crowns were removed along the path of insertion with a Zwick universal testing device. The impact of both a cured and a noncured additional bonding layer that were applied to the inner surface of the crowns was examined across the Dyract Cem group.The mean adhesive strength was measured at 2.36 +/- 0.69 N/mm2 in the Ketac Cem group, at 0.60 +/- 0.28 N/mm2 in the F21 group, and at 1.85 +/- 0.94 N/mm2 in the Dyract Cem group, respectively. The application of an additional bonding layer to the inner surface of the crowns d…
In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents
2005
Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…
Luting of ceramic crowns with a self-adhesive cement: Effect of contamination on marginal adaptation and fracture strength
2012
Objectives: This study evaluated the percentages of continuous margins (%CM) and fracture strength (FS) of crowns made out from blocs of leucite-reinforced ceramic (IPS Empress CAD) and luted with a representative self-adhesive cement (RelyX Unicem) under four contaminating agents: saliva, water, blood, a haemostatic solution containing aluminium chloride (pH= 0.8) and a control group with no contamination. Study Design: %CM at both tooth-cement (TC) and cement-crown (CC) interfaces were determined before and after a fatigue test consisting of 600’000 chewing loads and 1’500 temperature cycles changing from 5º C to 50º C. Load to fracture was recorded on fatigued specimens. Kruskal-Wallis t…
Interferometric microscopy study of the surface roughness of Portland cement under the action of different irrigants
2013
Objectives: Some investigations suggested common Portland cement (PC) as a substitute material for MTA for endodontic use; both MTA and PC have a similar composition. The aim of this study was to determine the surface roughness of common PC before and after the exposition to different endodontic irrigating solutions: 10% and 20% citric acid, 17% ethylenediaminetetraacetic (EDTA) and 5% sodium hypochlorite. Study Design: Fifty PC samples in the form of cubes were prepared. PC was mixed with distilled water (powder/liquid ratio 3:1 by weight). The samples were immersed for one minute in 10% and 20% citric acid, 17% EDTA and 5% sodium hypochlorite. After gold coating, PC samples were examined …
Marginal integrity of class V restorations: SEM versus dye penetration.
2006
To perform an in vitro investigation on the marginal integrity of different adhesives (Optibond FL, Scotchbond 1XT, Clearfil SE Bond, Adper Prompt L-Pop, S(3) Bond, iBond exp., Adper Prompt L-Pop) in combination with Tetric Ceram as well as an experimental silorane-restorative (Hermes, Hermes Bond; 3M ESPE) using SEM and dye penetration (2% methylene blue) in a comparative manner.Standardized class V-cavities (3 mm x 1.5 mm) were prepared in 70 extracted human teeth (n=10). The adhesives were applied according to manufacturers' instructions. The cavities were restored with three increments. After finishing and polishing (Sof-Lex discs) and thermocycling (5000x, 5/55 degrees C), replicas wer…
Marginal integrity of different resin-based composites for posterior teeth: an in vitro dye-penetration study on eight resin-composite and compomer-/…
2002
Abstract Objective: To determine improvements in marginal adaptation of resin-based composite restorative systems by means of flow-composites (Solitaire 2/Gluma Solid Bond, Solitaire 2/Flow Line/Gluma Solid Bond, Point 4/Optibond Solo Plus, Point 4/Revolution/Optibond Solo Plus) and to determine the equality of simplified bonding systems (Solitaire 2/Gluma Comfort Bond, Tetric Ceram/Tetric Flow/Excite, Dyract AP/Prime & Bond NT/NRC, Pertac II/Prompt-L-Pop) in marginal gap formation. Methods: The marginal dye penetration (2% methylene-blue) was investigated separately for the approximal boxes of Class II mod-cavities with one cervical margin of the approximal box within enamel, the other wit…
Sealing ability of five different retrograde filling materials.
1996
The sealing ability of Amalgam, Harvard-Cement, Diaket, gold-leaf, and Ketac-Endo as retrofilling materials was investigated. Paper cones were fixed with Harvard-Cement in the instrumented roots of 100 extracted human incisors. Apicectomy was performed and a 2-mm-deep retrograde cavity was prepared. Teeth were assigned to five groups (n = 20); each group received a different filling material. Surfaces of the roots were isolated with nail polish. Teeth, were stored in 1% methylene blue dye for 72 h. Roots were sectioned, and the depth of dye penetration was evaluated through a stereomicroscope. Retrofills with Ketac-Endo showed significantly less leakage compared with amalgam. There was no s…
Information and Investor Behavior Surrounding Earnings Announcements
2014
Preliminary version The goal of this paper is to analyze the impact of annual earnings announcements on the market through the order flow data in addition to the usual transaction data. In this respect, examining order flow data can potentially reveal valuable information which is not available from transaction data. In fact, the data allow us to test hypotheses about asymmetric information and investor behavior and to test if the behavior varies with investor sophistication. In addition, the paper tries to identify the determinants of the impact on a firm's value using assumptions about investor behavior.
Molecular origin and hydration dependence of protein anharmonicity: an elastic neutron scattering study.
2010
Two main onsets of anharmonicity are present in protein dynamics. Neutron scattering on protein hydrated powders revealed a first onset at about 150 K and a second one at about 230 K (the so called dynamical transition). In order to assess the molecular origin of protein anharmonicity, we study different homomeric polypeptides by incoherent elastic neutron scattering, thus disentangling the contribution of different molecular groups in proteins. We show that methyl group rotations are the main contributors to the low temperature onset. Concerning the dynamical transition, we show that it also occurs in absence of side chains; however, the presence and mobility of side chains substantially i…