Search results for "Chemical analysis"

showing 10 items of 324 documents

Social Network Analysis and Qualitative Interviews for Assessing Geographic Characteristics of Tourism Business Networks.

2015

This study integrates quantitative social network analysis (SNA) and qualitative interviews for understanding tourism business links in isolated communities through analysing spatial characteristics. Two case studies are used, the Surselva-Gotthard region in the Swiss Alps and Longyearbyen in the Arctic archipelago of Svalbard, to test the spatial characteristics of physical proximity, isolation, and smallness for understanding tourism business links. In the larger Surselva-Gotthard region, we found a strong relationship between geographic separation of the three communities on compartmentalization of the collaboration network. A small set of businesses played a central role in steering col…

Computer and Information SciencesNorwegian PeoplePopulation DynamicsSocial Scienceslcsh:MedicineResearch and Analysis MethodsSocial NetworkingAnalytical ChemistryInterviews as TopicSvalbardGeographical LocationsSociologyChemical AnalysisSurveys and QuestionnairesHumansEthnicitiesCooperative Behaviorlcsh:SciencePopulation BiologyGeographylcsh:RCommerceSocial SupportBiology and Life SciencesPaleontologyQualitative StudiesGeographic DistributionNavigationEuropeChemistrySocial NetworksResearch DesignPaleogeographyPhysical SciencesPeople and PlacesEarth SciencesEngineering and TechnologyPopulation GroupingsSteeringlcsh:QQualitative AnalysisSwitzerlandNetwork AnalysisResearch ArticlePLoS ONE
researchProduct

Analysis of multi-source metabolomic data using joint and individual variation explained (JIVE).

2015

Metabolic profiling is increasingly being used for understanding biological processes but there is no single analytical technique that provides a complete quantitative or qualitative profiling of the metabolome. Data fusion (i.e. joint analysis of data from multiple sources) has the potential to circumvent this issue facilitating knowledge discovery and reliable biomarker identification. Another field of application of data fusion is the simultaneous analysis of metabolomic changes through several biofluids or tissues. However, metabolomics typically deals with large datasets, with hundreds to thousands of variables and the identification of shared and individual factors or structures acros…

Data sourceComputer scienceAnalytical techniqueStatistics as TopicAnalytical chemistryUrinalysisSensor fusioncomputer.software_genreBiochemistryAnalytical ChemistryMultiple dataMetabolomicsKnowledge extractionElectrochemistryEnvironmental ChemistryProfiling (information science)HumansMetabolomicsData miningcomputerSpectroscopyMulti-sourceBlood Chemical AnalysisSoftwareThe Analyst
researchProduct

Copper, iron and zinc determinations in human milk using FAAS with microwave digestion

2000

Abstract A method for determining copper, iron and zinc in human milk was optimized and validated. It includes microwave mineralization of the sample and measuring the elements by flame atomic absorption spectroscopy (FAAS). Only 2 ml of milk is needed, and the method is free of matrix interferences. The values obtained for the detection limits (0.07; 0.07; 0.11 μg/ml milk, for copper, iron and zinc) precision of the method, intra-assay (2.9; 5.2; 6.1%RSD for copper, iron and zinc) and accuracy, evaluated using recovery assays (98.8; 100.4; 95.9% for copper, iron and zinc) show that the method is useful for the purpose mentioned. Moreover, the method is rapid and simple, and the determinati…

Detection limitAccuracy and precisionChromatographyChemistryAnalytical chemistrychemistry.chemical_elementGeneral MedicineZincCopperAnalytical Chemistrylaw.inventionMatrix (chemical analysis)lawMicrowave digestionAtomic absorption spectroscopyAnalysis methodFood ScienceFood Chemistry
researchProduct

Green determination of eight water-soluble B vitamins in cosmetic products by liquid chromatography with ultraviolet detection.

2021

Abstract B vitamins are a group of compounds with beneficious properties for dermatologic care, and therefore they are included in the cosmetic formulations as high added-value ingredients. In this paper, an analytical method for the simultaneous determination of eight water-soluble B vitamins in cosmetic products is reported for the first time. This method is based on liquid chromatography with ultraviolet detection (LC-UV) analysis after simple water leaching of the analytes from the cosmetic matrix. No organic solvents are required, beyond the ethanol used in the chromatographic mobile phase. The proposed method has been successfully validated showing good linearity, limits of detection …

Detection limitAnalyteChromatographyChemistryClinical BiochemistryPharmaceutical ScienceReproducibility of ResultsWaterRepeatabilityCosmeticsmedicine.disease_causeAnalytical ChemistryMatrix (chemical analysis)B vitaminsWater solubleLeaching (chemistry)Drug DiscoveryVitamin B ComplexmedicineSolventsSpectroscopyUltravioletChromatography High Pressure LiquidChromatography LiquidJournal of pharmaceutical and biomedical analysis
researchProduct

New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aroma…

2008

Abstract Miniaturized matrix solid-phase dispersion (MSPD) was developed for the extraction of common polycyclic aromatic hydrocarbons (PAHs) from bivalve samples (100 mg, dry weight). Additional clean-up and analyte enrichment was accomplished by in-tube solid-phase microextraction (SPME). For this purpose the extracts collected after MSPD were diluted with water and injected into a capillary column coated with the extractive phase. This capillary column was connected to the analytical column by means of a switching valve. Separation and quantification of the PAHs were carried out using a monolithic LC column and fluorescence detection. Since the in-tube SPME device allowed the processing …

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryReproducibility of ResultsGeneral MedicineReference StandardsSolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryBivalviaMatrix (chemical analysis)AnimalsSample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

On-line trace enrichment for the determination of ethacrynic acid in urine by liquid chromatography and column-switching

1993

Abstract A chromatographic method based on liquid chromatography (LC) using column-switching for the determination of ethacrynic acid in urine samples, is described. The proposed system uses a Hypersil ODS-C18, 30 μm (20 mm × 2.1 mm i.d.) pre-column for the pre-concentration and separation of ethacrynic acid from the biological matrix. Polar urinary compounds are removed by flushing the pre-column with purified water, and the enriched analyte is then switched in back-flush mode onto an HP-LiChrospher RP C18, 5 μm (125 × 4 mm i.d.) analytical column, where it is chromatographed using an acetonitrile-acetate buffer gradient elution. The UV detector was set at 275 nm. The recovery of drug was …

Detection limitAnalyteChromatographyChemistrymedicine.medical_treatmentUrineBiochemistryPurified waterAnalytical ChemistryMatrix (chemical analysis)medicineEnvironmental ChemistryColumn switchingDiureticQuantitative analysis (chemistry)SpectroscopyAnalytica Chimica Acta
researchProduct

Simultaneous determination of oxybenzone and 2-ethylhexyl 4-methoxycinnamate in sunscreen formulations by flow injection-isodifferential derivative u…

2001

Abstract A flow injection procedure was developed for the simultaneous determination of two UV filters (oxybenzone and 2-ethylhexyl 4-methoxycinnamate) in sunscreen formulations, based on the isodifferential approach. The use of the second derivative spectra allowed a selective determination of the analytes free from matrix interferences and without pretreatment of samples. Standard solutions of the analytes were analyzed by the proposed procedure in order to select the appropriate wavelengths to solve the mixture. After this, the procedure was validated using commercial sunscreen formulations the concentrations of which were determined by an HPLC procedure. The two procedures gave comparab…

Detection limitAnalyteChromatographyInjection ProcedureAnalytical chemistryDerivativeStandard solutionBiochemistryAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundchemistryEnvironmental ChemistryOxybenzoneSpectroscopySecond derivativeAnalytica Chimica Acta
researchProduct

Spectrophotometric determination of phenols in water samples by the GHPSAM method

2001

Abstract The generalized H-point standard-additions method (GHPSAM) is proposed in order to obtain the phenol concentration in water samples when the matrix is completely unknown. The procedure involves solid-phase extraction in BondElut PPL cartridges and data handling of the UV-visible spectrophotometry measurements. The spectral regions where the unknown interferent behaviour can be considered as linear are found and the analyte concentration free from bias error is estimated. The percentages of recovery of phenols in spiked samples were similar to those obtained by HPLC. Cresols or chlorophenols can be also determined in real samples by this method. The concentration range tested was 0.…

Detection limitAnalyteChromatographymedicine.diagnostic_testChemistryHealth Toxicology and MutagenesisExtraction (chemistry)Public Health Environmental and Occupational HealthAnalytical chemistrySoil SciencePollutionHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundSpectrophotometrymedicineEnvironmental ChemistryPhenolSolid phase extractionWaste Management and DisposalWater Science and Technology
researchProduct

Sensitive determination of parabens in human urine and serum using methacrylate monoliths and reversed-phase capillary liquid chromatography-mass spe…

2014

A method for the determination of parabens in human urine and serum by capillary liquid chromatography (cLC) with UV-Vis and mass spectrometry (MS) detection using methacrylate ester-based monolithic columns has been developed. The influence of composition of polymerization mixture was studied. The optimum monolith was obtained with butyl methacrylate monomer at 60/40% (wt/wt) butyl methacrylate/ethylene dimethacrylate ratio and 50wt% porogens (composed of 36wt% of 1,4-butanediol, 54wt% 1-propanol and 10wt% water). Baseline resolution of analytes was achieved through a mobile phase of acetonitrile/water in gradient elution mode. Additionally, dispersive liquid-liquid microextraction (DLLME)…

Detection limitAnalytegeographyChromatography Reverse-PhaseChromatographygeography.geographical_feature_categoryResolution (mass spectrometry)ChemistryOrganic ChemistryParabensGeneral MedicineUrineUrinalysisMethacrylateMass spectrometryBiochemistryMass SpectrometryAnalytical ChemistryLiquid chromatography–mass spectrometryLimit of DetectionHumansMethacrylatesMonolithBlood Chemical AnalysisJournal of chromatography. A
researchProduct

Atomic absorption spectrometric determination of molybdenum in lubricating oils with use of emulsions

1985

Abstract Samples (0.1 g) containing molybdenum disulphide are digested with aqua regia or with a (1 + 1) hydrofluoric/nitric acid mixture, without complete destruction of the matrix, and the molybdenum is determined in an air/acetylene flame, after emulsification with a non-ionic surfactant (Nemol K-39). The detection limit is ca. 30 μg Mo g−1, and the r.s.d. is 2.9% for 6 analyses of a sample containing 6.5 mg Mo g−1.

Detection limitChemistryInorganic chemistrychemistry.chemical_elementBiochemistryAnalytical Chemistrylaw.inventionMatrix (chemical analysis)chemistry.chemical_compoundAcetylenePulmonary surfactantNitric acidMolybdenumlawEnvironmental ChemistryAqua regiaAtomic absorption spectroscopySpectroscopyAnalytica Chimica Acta
researchProduct