Search results for "Cherenkov"
showing 10 items of 142 documents
The experience of building and operating COMPASS RICH-1
2010
COMPASS RICH-1 is a large size gaseous Imaging Cherenkov Detector providing hadron identification in the range from 3 to 55 GeV/c, in the wide acceptance spectrometer of the COMPASS Experiment at CERN SPS. It uses a 3 m long C(4)F(10) radiator, a 21 m(2) large VUV mirror surface and two kinds of photon detectors: MAPMTs and MWPCs with CsI photocathodes, covering a total of 5.5 m(2). It is in operation since 2002 and its performance has increased in time thanks to progressive optimization and mostly to a major upgrade which was implemented in 2006. The main characteristics of COMPASS RICH-1 components are described and some specific aspects related to the radiator gas system, the mirror alig…
Energy spectrum of cosmic protons and helium nuclei by a hybrid measurement at 4300 m a.s.l.
2014
The energy spectrum of cosmic Hydrogen and Helium nuclei has been measured, below the so-called "knee", by using a hybrid experiment with a wide field-of-view Cherenkov telescope and the Resistive Plate Chamber (RPC) array of the ARGO-YBJ experiment at 4300 m above sea level. The Hydrogen and Helium nuclei have been well separated from other cosmic ray components by using a multi-parameter technique. A highly uniform energy resolution of about 25% is achieved throughout the whole energy range (100 TeV - 700 TeV). The observed energy spectrum is compatible with a single power law with index gamma=-2.63+/-0.06.
First measurement of f′2 (1525) production in Z0 hadronic decays
1996
The inclusive production of the f(2)'(1525) in hadronic Z(0) decays has been studied in data collected by the DELPHI detector at LEP. The Ring Imaging Cherenkov detectors were important tools in the identification of the decay f(2)'(1525) --> K+K-. The average number of f(2)(')(1525) produced per hadronic Z decay, [f(2)'] = 0.020 +/- 0.005 (stat) +/- 0.006 (syst), and the momentum distribution of the f(2)'(1525) have both been measured. The mass and width of the f(2)'(1525) are found to be [M(f2)'] = 1535 +/- 5 (stat) +/- 4 (syst) MeV/c(2). [Gamma(f2)'] = 60 +/- 20 (stat) +/- 19 (syst) MeV/c(2)
Improvement in fast particle track reconstruction with robust statistics
2014
The IceCube project has transformed one cubic kilometer of deep natural Antarctic ice into a Cherenkov detector. Muon neutrinos are detected and their direction inferred by mapping the light produced by the secondary muon track inside the volume instrumented with photomultipliers. Reconstructing the muon track from the observed light is challenging due to noise, light scattering in the ice medium, and the possibility of simultaneously having multiple muons inside the detector, resulting from the large flux of cosmic ray muons. This manuscript describes work on two problems: (1) the track reconstruction problem, in which, given a set of observations, the goal is to recover the track of a muo…
Performance of the DELPHI detector
1996
DELPHI (DEtector with Lepton, Photon and Hadron Identification) is a detector for e(+)e(-) physics, designed to provide high granularity over a 4 pi solid angle, allowing an effective particle identification, It has been operating at the LEP (Large Electron-Positron) collider at CERN since 1989. This article reviews its performance.
A Search for Heavy Stable and Long-Lived Squarks and Sleptons in $e^+ e^-$ Collisions at Energies from 130 to 183 GeV
1998
A search for stable and long-lived heavy charged particles used the data taken by the DELPHI experiment at energies from 130 to 183 GeV. The Cherenkov light detected in the Ring Imaging Cherenkov Detector and the ionization loss measured in the Time Projection Chamber identify heavy particles from masses of 2 to nearly 89 GeV/c$^2$. Upper limits are given on the production cross-section and masses of sleptons, free squarks with a charge of $q = \pm 2/3e$ and hadronizing squarks. A search for stable and long-lived heavy charged particles used the data taken by the DELPHI experiment at energies from 130 to 183 GeV. The Cherenkov light detected in the Ring Imaging Cherenkov Detector and the io…
An improved method for measuring muon energy using the truncated mean of dE/dx
2012
Nuclear instruments & methods in physics research / A 703, 190 - 198 (2013). doi:10.1016/j.nima.2012.11.081
Quintessence, inflation and baryogenesis from a single pseudo-Nambu-Goldstone boson
2007
15 pages, 3 figures.-- ISI Article Identifier: 000250759700079.-- ArXiv pre-print available at: http://arxiv.org/abs/0707.3999
Study of light backgrounds from relativistic electrons in air light-guides
2018
The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (M{\o}ller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the M{\o}ller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through …
Design and construction of the fast photon detection system for COMPASS RICH-1
2010
International audience; New photon detectors, based on the use of multi-anode photo-multiplier tubes coupled to individual lens telescopes and read out with a dedicated read-out electronics system, equip the central region of the Cherenkov imaging counter RICH-1 of the COMPASS experiment at CERN SPS. They are characterised by high photon yield, fast response and high rate capability and are successfully in operation since the 2006 COMPASS data taking. The photon detection system fully matches the expected performance. The design and construction of the photon detectors are described in detail.