Search results for "Coated Materials"
showing 7 items of 47 documents
External reinforcement of varicose veins with PTFE prosthesis in infrainguinal bypass surgery -- clinical results.
2003
OBJECTIVE Segmental varicose degeneration of the autogenous greater saphenous vein may limit its use in infrainguinal bypass surgery. Wrapping a PTFE prosthesis around dilated veins has emerged as an option to create externally reinforced vein bypasses. Results regarding graft patency and limb salvage were analyzed. METHODS Between September 1995 and January 2001, 35 infrainguinal bypass operations in 33 patients were performed with greater saphenous veins exhibiting segmental varicose dilatation. Grafts were followed by duplex scan and retrospective analysis of graft patency and limb salvage was performed. RESULTS One bypass prompted successful revision for early occlusion. Four bypasses r…
Biomaterials coated by dental pulp cells as substrate for neural stem cell differentiation
2011
[EN] This study is focused on the development of an in vitro hybrid system, consisting in a polymeric biomaterial covered by a dental pulp cellular stroma that acts as a scaffold offering a neurotrophic support for the subsequent survival and differentiation of neural stem Cells. In the first place, the behavior of dental pulp stroma on the polymeric biomaterial based on ethyl acrylate and hydroxy ethyl acrylate copolymer was studied. For this purpose, cells from normal human third molars were grown onto 0.5-mm-diameter biomaterial discs. After cell culture, quantification of neurotrophic factors generated by the stromal cells was performed by means of an ELISA assay. In the second place, s…
In vivo comparison of a granular and putty form of a sintered and a non-sintered silica-enhanced hydroxyapatite bone substitute material
2019
Improved handling characteristics of bone substitute materials may facilitate surgical handling. However, the respective modifications should not alter the biological activity. For comparison of a ...
A plasma protein corona enhances the biocompatibility of Au@Fe3O4 Janus particles
2015
AbstractAu@Fe3O4 Janus particles (JPs) are heteroparticles with discrete domains defined by different materials. Their tunable composition and morphology confer multimodal and versatile capabilities for use as contrast agents and drug carriers in future medicine. Au@Fe3O4 JPs have colloidal properties and surface characteristics leading to interactions with proteins in biological fluids. The resulting protein adsorption layer (“protein corona”) critically affects their interaction with living matter. Although Au@Fe3O4 JPs displayed good biocompatibility in a standardized in vitro situation, an in-depth characterization of the protein corona is of prime importance to unravel underlying mecha…
Physicochemical Surface Properties of Various Intraocular Lenses
2001
<i>Purpose:</i> It is of major interest to understand how intraocular lens (IOL) surfaces interact with aqueous humor or tissues after implantation. Important parameters to describe the physicochemical surface properties are the contact angle and critical surface tension. Therefore, we performed measurements of the contact angle and critical surface tension of several commercially available IOLs. <i>Setting:</i> Department of Ophthalmology, Johannes Gutenberg University, Mainz, University Eye Hospital, Tübingen, and Max Planck Institute for Polymer Research, Mainz, Germany. <i>Methods:</i> A total of 17 commercially available standard quality IOL types (6…
Dose-dependent osteoinductive effects of bFGF in rabbits.
2009
Growth factors lead to the induction of tissue regeneration in bone healing when coated on biomaterials. Basic fibroblast growth factor (bFGF) combines osteoinduction and neoangiogenesis. This study evaluated bFGF-coated hydroxylapatite implants in two experimental groups with 10 or 100 microg (n = 5 per group) compared with uncoated control implants in the rabbit patellar groove model. We observed an unexpected ineffectiveness compared to the control groups with no significant difference of bone growth after 35 days. However, all samples from the 100 microg experiment (control and coated implant) showed significantly stronger 19-25 day label than both 10 microg groups (control and coated i…
Modern Strategies in the Prevention of Implant-Associated Infections
2005
The application of medical devices either for temporary or permanent use has become an indispensible part of almost all fields of medicine. However, foreign bodies are associated with a substantial risk of bacterial and fungal infections. Implant-associated infections significantly contribute to the still increasing problem of nosocomial infections. To reduce the incidence of such infections, specific guidelines providing evidence-based recommendations and comprising both technological and nontechnological strategies for prevention have been established. Strict adherence to hygienic rules during insertion or implantation of the device are aspects of particular importance. Besides such basi…