Analysis of spectral irradiance distribution for PV applications at high latitude
2020
The spectral distribution of global tilted irradiance measured in Grimstad, Norway, is analyzed in terms of the average photon energy ( $APE$ ) blue fraction ( $BF$ ) and useful fraction ( $UF$ ). The results based on eight months of recorded data show a general shift of the $APE,\ BF$ , and $UF$ values to higher values than reference AM1.5G spectrum, with 1.63 eV, 0.45, and 0.88 being the average indices, respectively. The statistical coefficient of variation ( $CV$ ) is used to determine the variation of indices. The $CV$ for $APE,\ BF$ , and $UF$ are calculated to be 20.1%, 26.1%, and 25.7%, respectively confirming the earlier findings on $APE$ being a more accurate index for the quantif…
Estimating field-saturated soil hydraulic conductivity by a simplified Beerkan infiltration experiment
2012
Field-saturated soil hydraulic conductivity, Kfs, is highly variable. Therefore, interpreting and simulating hydrological processes, such as rainfall excess generation, need a large number of Kfs data even at the plot scale. Simple and reasonably rapid experiments should be carried out in the field. In this investigation, a simple infiltration experiment with a ring inserted shortly into the soil and the estimation of the so-called α* parameter allowed to obtain an approximate measurement of Kfs. The theoretical approach was tested with reference to 149 sampling points established on Burundian soils. The estimated Kfs with the value of first approximation of α* for most agricultural field s…
Intra‐ and inter‐instrument reliability of the Actiwatch 4 accelerometer in a mechanical laboratory setting.
2012
Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting This study aimed to quantify the intra-and inter-instrument reliability of the Actiwatch 4 accelerometer (AW4) in a mechanical setting. Twenty seven AW4 were attached to an isokinetic dynamometer and subjected to angular acceleration for 30 min at 50 deg/sec representing moderate intensity (MPA condition) and 200 deg/sec representing vigorous intensity (VPA condition), with a repeat trial conducted. Reliability was assessed using coefficient of variation (CV), absolute percent error (APE), and intraclass correlation coefficients (ICC). Mean AW4 activity counts displayed acceptable rel…
GAS CHROMATOGRAPHIC ESTIMATION OF ACETYLCHOLINE IN THE RABBIT HEART USING A NITROGEN SELECTIVE DETECTOR
1973
The distribution of ACh in the rabbit heart was investigated by a modified gas chromatographic estimation method. ACh was extracted with perchloric acid, precipitated as reineckate and demethylated with sodium benzenethiolate. The tertiary amines derived from ACh and other choline esters were concentrated by a microdistillation procedure. Gas chromatography was performed using a nitrogen selective detector. In the range of concentrations between 0.4 and 2.5 nmol ACh per tissue sample the coefficient of variation was 5.2 per cent. The recovery of ACh added to heart extracts was 101 per cent. Evidence for the identity of the choline ester isolated from rabbit hearts and authentic ACh was obta…
Determination of globotriaosylceramide in plasma and urine by mass spectrometry
2009
Abstract Background: Fabry disease is an X-chromosomally inherited lysosomal storage disorder leading to accumulation of glycosphingolipids, mainly globotriaosylceramide (ceramide-trihexoside, Gb3). Concentrations of Gb3 in plasma and urine have been used to diagnose Fabry disease and to monitor enzyme replacement therapy with recombinant α-galactosidase. Methods: Gb3 was purified from plasma or urine by combined liquid extraction/protein precipitation and solid-phase extraction, and was detected by flow-injection analysis electrospray mass spectrometry (MS) using multi-reaction-monitoring. Calibration was performed via standard addition using C17-Gb3 as internal standard. The most abundant…
Assessing Repeatability and Reproducibility of Anterior Active Rhinomanometry (AAR) in Children
2020
AbstractBackgroundRepeatability and reproducibility are essential for clinicians for several purposes. Although discouraged, use of the Coefficient of Variation (CV) for assessing repeatability and reproducibility, rather than the Intraclass Correlation Coefficient (ICC), is still widespread. The aim of the present study was to highlight how using inappropriate indices may lead to misleading results, and this is done by simulation study and using real data on Anterior Active Rhinomanometry (AAR) in both healthy children and ones with rhinitis.MethodsA simulation study was carried out to highlight how using inappropriate indices could be misleading. Then a comparison was made between CV and …
Individual Patterns in Blood-Borne Indicators of Fatigue-Trait or Chance.
2017
Julian, R, Meyer, T, Fullagar, HHK, Skorski, S, Pfeiffer, M, Kellmann, M, Ferrauti, A, and Hecksteden, A. Individual patterns in blood-borne indicators of fatigue-trait or chance. J Strength Cond Res 31(3): 608-619, 2017-Blood-borne markers of fatigue such as creatine kinase (CK) and urea (U) are widely used to fine-tune training recommendations. However, predictive accuracy is low. A possible explanation for this dissatisfactory characteristic is the propensity of athletes to react to different patterns of fatigue indicators (e.g., predominantly muscular [CK] or metabolic [U]). The aim of the present trial was to explore this hypothesis by using repetitive fatigue-recovery cycles. A total …
Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis
2017
PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…
Force-velocity profiling in athletes: Reliability and agreement across methods
2021
The aim of the study was to examine the test-retest reliability and agreement across methods for assessing individual force-velocity (FV) profiles of the lower limbs in athletes. Using a multicenter approach, 27 male athletes completed all measurements for the main analysis, with up to 82 male and female athletes on some measurements. The athletes were tested twice before and twice after a 2- to 6-month period of regular training and sport participation. The double testing sessions were separated by ~1 week. Individual FV-profiles were acquired from incremental loading protocols in squat jump (SJ), countermovement jump (CMJ) and leg press. A force plate, linear encoder and a flight time cal…
Validation of lung densitometry threshold at CT for the distinction between senile lung and emphysema in elderly subjects
2015
Background and Aims. An ageing lung is characterised by distal airspace enlargement without alveolar wall destruction: therefore the anatomical distinction between senile lung and emphysema is clear-cut. In clinical settings the definition of precise boundaries between normalcy and pathology is more difficult with the risk of overdiagnosis. CT is an important diagnostic advancement in the field of COPD. Most methods for the evaluation of emphysema are based on the detection and measurement of areas characterised by a density level below a threshold assumed to characterize parenchymal destruction. Methods. Our retrospective study included 47 healthy subjects (65-91 years), 36 never smokers a…