Search results for "Coherence tomography"

showing 10 items of 150 documents

CORRELATION OF OPTICAL COHERENCE TOMOGRAPHY PATTERN AND VISUAL RECOVERY AFTER VITRECTOMY WITH SILICONE OIL FOR RETINAL DETACHMENT

2006

PURPOSE: To assess prospectively the features of the macular surface in silicone oil-filled eyes after surgery by analyzing whether silicone oil affects optical coherence tomography (OCT) measurements and their reproducibility and whether a statistical correlation exists between postoperative best-corrected visual acuity (BCVA) and foveal thickness measured by OCT. METHODS: Twenty eyes of 20 patients underwent vitrectomy with silicone oil tamponade for retinal detachment. After vitrectomy, complete ophthalmic examination including determination of BCVA and OCT was performed to quantify the visual recovery and the foveal thickness. RESULTS: Ophthalmoscopy revealed that the retina appeared to…

AdultMaleFovea Centralismedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentsilicone oilVisual AcuityVitrectomyOphthalmoscopyOptical coherence tomographyVitrectomyOphthalmologyfoveal thicknemedicineHumansSilicone OilsProspective StudiesPostoperative PeriodAgedoptical coherence tomographyFovea Centralimedicine.diagnostic_testbusiness.industryRetinal DetachmentFovea centralisRetinal detachmentRecovery of FunctionGeneral Medicinevisual recoveryMiddle Agedmedicine.diseaseCombined Modality Therapyeye diseasesOphthalmoscopyVitreous BodyProspective StudieOphthalmologymedicine.anatomical_structureVitreous chamberFemalesense organsTamponademedicine.symptombusinessTomography Optical CoherenceHumanRetina
researchProduct

Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery

2009

PURPOSE To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS In the biaxial group, median foveal thickness changed from 160 microm preoperatively to 168 microm 8 weeks postoperatively (p=0.018…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityFoveal thicknessMacular EdemaCornea03 medical and health sciencesPostoperative Complications0302 clinical medicineOptical coherence tomographyOphthalmologyBlood-Retinal BarrierHumansMedicineMacula LuteaProspective StudiesIntraoperative ComplicationsAgedAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industrySignificant differenceGeneral MedicinePhacoemulsificationMiddle AgedCataract surgeryeye diseasesOphthalmologySmall incision030221 ophthalmology & optometryFemalesense organsmedicine.symptomCoaxialbusinessTomography Optical Coherence030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

2019

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …

AdultMalemedicine.medical_specialtyBiometryHigh resolutionVergenceStatistics NonparametricYoung Adult03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOptical coherence tomographyReference ValuesOphthalmologyHumansMedicineTomographyMúsculo ciliarBiometriaAnalysis of Variancemedicine.diagnostic_testbusiness.industryCiliary BodyOptical coherenceBiomechanicsAccommodation OcularPresbyopiaGeneral MedicinePresbyopiamedicine.diseaseBiomechanical PhenomenaCiliary muscleOphthalmologyCiliary musclelcsh:RE1-994Acomodação ocularTomografia de coerência ópticaAccommodation ocularLinear Models030221 ophthalmology & optometryPositive relationshipFemalesense organsPresbiopiabusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

OCT is not useful for detection of minimal diabetic retinopathy in type 1 diabetes.

2009

Optical coherence tomography (OCT) has been proven useful in measuring retinal thickness (RT) in patients with diabetes, although with discordant results in different studies. We examined RT in patients with type 1 diabetes (T1D) with or without minimal diabetic retinopathy (MDR) to test whether OCT is able to identify early retinal changes and potential correlations with metabolic parameters. RT of 102 patients with T1D (53 females, 49 males, aged 27.03 +/- 7.4 years) and of 42 healthy controls was examined, with analysis of nine different sectors (fovea, four pericentral and four peripheral sectors). According to the results of basal fundus photography, patients were divided into two grou…

AdultMalemedicine.medical_specialtyEndocrinology Diabetes and MetabolismGastroenterologyRetinaSettore MED/13 - EndocrinologiaYoung AdultEndocrinologyOptical coherence tomography (OCT) type 1 diabetes (T1D) minimal diabetic retinopathy (MDR)retinal thickness (RT)Predictive Value of TestsInternal medicineDiabetes mellitusInternal MedicinemedicineHumansHypoglycemic AgentsInsulinMacular edemaType 1 diabetesDiabetic Retinopathymedicine.diagnostic_testbusiness.industrySettore MED/30 - Malattie Apparato VisivoFundus photographyGeneral MedicineDiabetic retinopathymedicine.diseaseRadiographyEndocrinologyDiabetes Mellitus Type 1Predictive value of testsMicroalbuminuriaFemalebusinessMedical FutilityTomography Optical CoherenceRetinopathy
researchProduct

Assessment of corneal thickness and tear meniscus during contact-lens wear

2014

To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…

AdultMalemedicine.medical_specialtyMaterials sciencegenetic structuresSurface PropertiesCorneaYoung AdultOptical coherence tomographyOphthalmologyCorneaMyopiamedicineHumansmedicine.diagnostic_testHealthy subjectsGeneral MedicineContact Lenses Hydrophiliceye diseasesContact lensOphthalmologyTear meniscusmedicine.anatomical_structureTearsTearsFemaleDaily disposablesense organsTomography Optical CoherenceOptometryContact Lens and Anterior Eye
researchProduct

Avaliação por OCT in vivo do comprimentos axiais centrais do segmento anterior

2017

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any s…

AdultMalemedicine.medical_specialtySegmento anterior do olhoPosterior poleOcular physiologyYoung AdultOcular accommodationOptical coherence tomographyLens thicknesslcsh:OphthalmologyAnterior Eye SegmentOphthalmologymedicineHumansmedicine.diagnostic_testOptical coherence tomographybusiness.industrySegment lengthAccommodation OcularGeneral MedicineMiddle AgedAnterior eye segmentAnterior Eye SegmentOphthalmologylcsh:RE1-994Acomodação ocularTomografia de coerência ópticaFemaleTomographysense organsbusinessAccommodationTomography Optical Coherence
researchProduct

Visualization of corneal vascularization in peripheral hypertrophic subepithelial corneal opacification with OCT angiography.

2018

Purpose The major goal of this study was to test the hypothesis that in patients with peripheral hypertrophic subepithelial corneal opacification (PHSCO), visualization of corneal vessels is better with optical coherence tomography angiography (OCTA) than with conventional slit lamp microphotography. Methods Patients with PHSCO were included in this prospective study. The corneal findings were photographed using a slit lamp camera (Haag Streit BM 900® ) and visualized with anterior-segment OCT (Optovue XR Avanti, Fremont, California, USA). Additionally, OCTA with the Angiovue Imaging™ System was performed in the area of PHSCO. Results Thirty-four eyes of 19 patients (26% male and 74% female…

AdultMalemedicine.medical_specialtyTime Factorsgenetic structuresFundus OculiSlit Lamp MicroscopyCornea03 medical and health sciences0302 clinical medicineOct angiographyCorneal OpacityOphthalmologyMedicineHumansIn patientCorneal NeovascularizationProspective StudiesFluorescein AngiographyAgedAged 80 and overSlit lampbusiness.industryEpithelium CornealReproducibility of ResultsGeneral MedicineOptical coherence tomography angiographyMiddle Agedmedicine.diseaseeye diseasesPeripheralOphthalmologyCorneal neovascularization030221 ophthalmology & optometryCorneal vascularizationFemalesense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceFollow-Up StudiesActa ophthalmologica
researchProduct

Bilateral maculopathy after exposure to a laser pointer: Optical coherence tomography angiography findings.

2018

Abstract Case report A 36-year-old man went to the emergency department the day after exposure to a laser pointer. Funduscopy revealed dispersed macular pigment alterations, and optical coherence tomography showed a disruption of the retinal layers. The visual acuity was counting fingers in both eyes. Nine months later, optical coherence tomography angiography showed a rarefaction in the choriocapillaris vascular flow in the area of the laser injuries. Discussion The retinal layer mainly damaged by the laser injury was the retinal pigment epithelium. However, it is suggested that the laser injury could involve tissues beyond the retinal pigment epithelium, since a rarefaction of the chorioc…

AdultMalemedicine.medical_specialtyVisual acuitygenetic structuresRetinal Pigment Epitheliumlaw.invention03 medical and health scienceschemistry.chemical_compound0302 clinical medicineEye InjuriesOptical coherence tomographylawOphthalmologymedicineHumansMacula LuteaFluorescein AngiographyRetinal pigment epitheliummedicine.diagnostic_testbusiness.industryChoroidCystsLasersRetinalGeneral MedicineOptical coherence tomography angiographymedicine.diseaseLasereye diseasesmedicine.anatomical_structurechemistry030221 ophthalmology & optometryLaser pointerMaculopathysense organsmedicine.symptomEmergenciesbusiness030217 neurology & neurosurgeryTomography Optical Coherence
researchProduct

Optical coherence tomography-based retinal vessel analysis for the evaluation of hypertensive vasculopathy

2013

Purpose Evaluation of retinal vessels in cardiovascular disease traditionally relies upon funduscopy, but more recently digital photo analysis has expanded the spectrum. As spectral domain optical coherence tomography (OCT) allows an in-vivo assessment of retinal tissue and its vessels on a histological scale, our study aimed at using this tool for the analysis of the retinal vasculature. Methods Circumferential peripapillary OCT scans (3DOCT-2000; Topcon Inc., Tokyo, Japan), with centration on the optic nerve head, were taken from 20 eyes (20 participants) with normal blood pressure and 20 eyes (20 participants) with arterial hypertension above 120 mmHg (mean blood pressure). The diameter …

AdultMalemedicine.medical_specialtygenetic structuresRetinal ArteryHypertensive Retinopathychemistry.chemical_compoundOptical coherence tomographyHypertensive retinopathyOphthalmologymedicineHumansArterial Pressuremedicine.diagnostic_testbusiness.industryBlood Pressure DeterminationRetinalGeneral MedicineMiddle Agedmedicine.diseaseRetinal VeinSurgeryRetinal vesselOphthalmologyMean blood pressureBlood pressurechemistryOptic nerveArterial bloodFemalesense organsbusinessVenous PressureTomography Optical CoherenceActa Ophthalmologica
researchProduct

Evaluating tear clearance rate with optical coherence tomography

2017

Purpose: To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. Methods: TCR was classified as the percentage decrease of the inferior tear meniscus height 30s after instillation of 5uL 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean +/- standard deviation) 25.5 +/- 4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR …

AdultMalemedicine.medical_specialtymedicine.medical_treatmentDry Eye SyndromesFOS: Physical sciencesLacrimal apparatusSlit Lamp Microscopy03 medical and health sciencesYoung Adult0302 clinical medicineOptical coherence tomographyOphthalmologyTear meniscus heightmedicineHumansOcular Surface Disease IndexSalineFluorescent Dyesmedicine.diagnostic_testbusiness.industryLacrimal ApparatusGeneral MedicinePhysics - Medical Physicseye diseasesSurgeryOphthalmologyTear meniscusmedicine.anatomical_structureTears030221 ophthalmology & optometryTearsDry Eye SyndromesFemaleFluoresceinMedical Physics (physics.med-ph)sense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceOptometryOptics (physics.optics)Physics - Optics
researchProduct