Search results for "Coherence"

showing 10 items of 905 documents

OCT is not useful for detection of minimal diabetic retinopathy in type 1 diabetes.

2009

Optical coherence tomography (OCT) has been proven useful in measuring retinal thickness (RT) in patients with diabetes, although with discordant results in different studies. We examined RT in patients with type 1 diabetes (T1D) with or without minimal diabetic retinopathy (MDR) to test whether OCT is able to identify early retinal changes and potential correlations with metabolic parameters. RT of 102 patients with T1D (53 females, 49 males, aged 27.03 +/- 7.4 years) and of 42 healthy controls was examined, with analysis of nine different sectors (fovea, four pericentral and four peripheral sectors). According to the results of basal fundus photography, patients were divided into two grou…

AdultMalemedicine.medical_specialtyEndocrinology Diabetes and MetabolismGastroenterologyRetinaSettore MED/13 - EndocrinologiaYoung AdultEndocrinologyOptical coherence tomography (OCT) type 1 diabetes (T1D) minimal diabetic retinopathy (MDR)retinal thickness (RT)Predictive Value of TestsInternal medicineDiabetes mellitusInternal MedicinemedicineHumansHypoglycemic AgentsInsulinMacular edemaType 1 diabetesDiabetic Retinopathymedicine.diagnostic_testbusiness.industrySettore MED/30 - Malattie Apparato VisivoFundus photographyGeneral MedicineDiabetic retinopathymedicine.diseaseRadiographyEndocrinologyDiabetes Mellitus Type 1Predictive value of testsMicroalbuminuriaFemalebusinessMedical FutilityTomography Optical CoherenceRetinopathy
researchProduct

Coronary embolism in a young patient with nonbacterial thrombotic endocarditis related to antiphospholipid syndrome

2020

myocardial infarction

AdultMalemedicine.medical_specialtyMEDLINEMagnetic Resonance Imaging CineCoronary AngiographyNonbacterial thrombotic endocarditisAntiphospholipid syndromeInternal medicinemedicineHumansAngioplasty Balloon Coronarycoronary embolismHeart Valve Prosthesis Implantationbusiness.industryGeneral MedicineAntiphospholipid SyndromeCoronary embolismmedicine.diseaseAortic Valve DiseaseTreatment OutcomeCoronary OcclusionEndocarditis Non-InfectiveCardiologyST Elevation Myocardial InfarctionCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealTomography Optical Coherence
researchProduct

Assessment of corneal thickness and tear meniscus during contact-lens wear

2014

To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…

AdultMalemedicine.medical_specialtyMaterials sciencegenetic structuresSurface PropertiesCorneaYoung AdultOptical coherence tomographyOphthalmologyCorneaMyopiamedicineHumansmedicine.diagnostic_testHealthy subjectsGeneral MedicineContact Lenses Hydrophiliceye diseasesContact lensOphthalmologyTear meniscusmedicine.anatomical_structureTearsTearsFemaleDaily disposablesense organsTomography Optical CoherenceOptometryContact Lens and Anterior Eye
researchProduct

Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.

2008

To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…

AdultMalemedicine.medical_specialtyMydriaticsMaterials scienceBiometrygenetic structuresLightAnterior ChamberDiagnostic Techniques OphthalmologicalEyeCorneaLens thicknessOphthalmologyLens CrystallinemedicineHumansBody Weights and Measuresbusiness.industryUltrasoundReproducibility of ResultsCycloplegiaPupileye diseasesSensory SystemsSurgeryOphthalmologyInterferometrySoundPartial coherence interferometrySurgeryFemalesense organsmedicine.symptombusinessPartial coherenceJournal of cataract and refractive surgery
researchProduct

Retinal Imaging through Phakic Iris-Claw IOL.

2014

AbstractBackground: Phakic anterior chamber iris-fixated IOL (PIOL) are established for the correction of high myopia. These patients require attention to macular pathologies. This study was to evaluate the quality of imaging through the PIOLs. Methods: 54 eyes of 31 myopic and hyperopic patients with Verisyse®, Verisyse toric®, and Veriflex® phakic iris-fixated IOL were included. Mean preoperative refraction was −11.0 D and +5.7 D, respectively; mean follow-up time was 7.4 years (5–11 years). A matched control group was formed without PIOL implantation. OCT scans were performed and evaluated qualitatively and quantitatively. Results: In 52 eyes of 31 patients (96%), a 3D-OCT image and fund…

AdultMalemedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresAnterior ChamberVisual AcuityIrisFoveal thicknessFundus (eye)Refraction OcularRetinaImaging Three-DimensionalLens Implantation IntraocularOphthalmologymedicineMyopiaHumansPhakic iolIris clawmedicine.diagnostic_testbusiness.industrySignificant differenceFundus photographyHigh myopiaGeneral MedicineMiddle Agedeye diseasesOphthalmologyHyperopiaRetinal imagingFemalesense organsbusinessTomography Optical CoherenceFollow-Up StudiesSeminars in ophthalmology
researchProduct

Association between early-stage chronic kidney disease and reduced choroidal thickness in essential hypertensive patients.

2018

The introduction in the past few years of advanced optical coherence tomography (OCT) techniques has greatly increased our understanding of the choroid, which is the most important vascular layer of the eye. Our study aimed to assess choroidal thickness by using swept-source OCT (SS-OCT) in essential hypertensive patients (EHs) with and without early-stage chronic kidney disease (CKD). We enrolled 100 EHs, of whom 65 were without kidney damage, and 35 had stage 1-3 CKD. In all of the participants, SS-OCT and a routine biochemical workup were performed. Glomerular filtration rate (GFR) was estimated by the CKD Epidemiology Collaboration equation (eGFR). CKD was defined in agreement with the …

AdultMalemedicine.medical_specialtyPhysiologyUrologyRenal function030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineRenal damageInternal MedicinemedicineHumans030212 general & internal medicineProspective StudiesRenal Insufficiency ChronicAgedKidneyHypertensive eye diseasebusiness.industryChoroidMicrocirculationConfoundingDiabetic retinopathyOdds ratioMiddle Agedmedicine.diseaseeye diseasesConfidence intervalmedicine.anatomical_structureRenal dysfunctionFemalesense organsChoroidEssential HypertensionCardiology and Cardiovascular MedicinebusinessTomography Optical CoherenceKidney diseaseHypertension research : official journal of the Japanese Society of Hypertension
researchProduct

Avaliação por OCT in vivo do comprimentos axiais centrais do segmento anterior

2017

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any s…

AdultMalemedicine.medical_specialtySegmento anterior do olhoPosterior poleOcular physiologyYoung AdultOcular accommodationOptical coherence tomographyLens thicknesslcsh:OphthalmologyAnterior Eye SegmentOphthalmologymedicineHumansmedicine.diagnostic_testOptical coherence tomographybusiness.industrySegment lengthAccommodation OcularGeneral MedicineMiddle AgedAnterior eye segmentAnterior Eye SegmentOphthalmologylcsh:RE1-994Acomodação ocularTomografia de coerência ópticaFemaleTomographysense organsbusinessAccommodationTomography Optical Coherence
researchProduct

Causal cross-spectral analysis of heart rate and blood pressure variability for describing the impairment of the cardiovascular control in neurally m…

2006

A causal approach to the calculation of coherence and transfer function between systolic pressure (SP) and RR interval variability was applied in eight patients and eight control subjects during prolonged tilt test for investigating the impairment of cardiovascular control related to neurally mediated syncope. The causal analysis showed a depressed baroreflex regulation in resting patients, with reduced gain and increased latency from SP to RR, and a drop of the baroreflex coupling immediately before syncope. These findings, which were not elicited by traditional cross-spectral analysis, strongly suggest the use of the causal approach for the study of syncope mechanisms. © 2006 IEEE.

AdultMalemedicine.medical_specialtyStatistics as TopicBiomedical EngineeringBlood PressureNeurally-mediated syncopeCardiovascular controlBaroreflexCardiovascular SystemSensitivity and SpecificitySeverity of Illness IndexFeedbackElectrocardiographyHeart RateInternal medicineSeverity of illnessHeart rateSyncope VasovagalmedicineHumansComputer SimulationDiagnosis Computer-AssistedModels Statisticalmedicine.diagnostic_testbusiness.industryTransfer functionModels CardiovascularReproducibility of ResultsBaroreflexBlood pressureData Interpretation StatisticalAnesthesiaCardiologyRegression AnalysisFemalebusinessElectrocardiographyCoherenceAlgorithmsSyncope (phonology)
researchProduct

Measuring postural-related changes of spontaneous baroreflex sensitivity after repeated long-duration diving: Frequency domain approaches

2012

Sustained water immersion is thought to modulate orthostatic tolerance to an extent dependent on the duration and repetition over consecutive days of the diving sessions. We tested this hypothesis investigating in ten healthy subjects the potential changes in the cardiovascular response to head-up tilt induced by single and multiple resting air dives. Parametric cross-spectral analysis of spontaneous RR interval and systolic arterial pressure variability was performed in three experimental sessions: before diving (BD), after single 6-hour dive (ASD), and after multiple 6-hour dives (AMD, 5 consecutive days with 18-hour surface interval). From this analysis, baroreflex sensitivity (BRS) was …

AdultMalemedicine.medical_specialtySupine positionDivingPostureRR intervalOrthostatic intoleranceBaroreflexSensitivity and SpecificityEndocrine and Autonomic SystemCellular and Molecular NeuroscienceOrthostatic vital signsInternal medicinemedicineHumansShort durationAnalysis of VarianceElectronic Data ProcessingEndocrine and Autonomic Systemsbusiness.industrySpectrum AnalysisHead-up tiltBaroreflexCardiovascular variabilitymedicine.diseaseCausal coherenceParametric cross-spectral analysiFrequency domainSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaPower ratioCardiologyNeurology (clinical)businessOrthostatic toleranceAutonomic Neuroscience
researchProduct

Exploring directionality in spontaneous heart period and systolic pressure variability interactions in humans: implications in the evaluation of baro…

2004

Although in physiological conditions RR interval and systolic arterial pressure (SAP) are likely to interact in a closed loop, the traditional cross-spectral analysis cannot distinguish feedback (FB) from feedforward (FF) influences. In this study, a causal approach was applied for calculating the coherence from SAP to RR ( Ks-r) and from RR to SAP ( Kr-s) and the gain and phase of the baroreflex transfer function. The method was applied, compared with the noncausal one, to RR and SAP series taken from 15 healthy young subjects in the supine position and after passive head-up tilt. For the low frequency (0.04–0.15 Hz) spectral component, the enhanced FF coupling ( Kr-s = 0.59 ± 0.21, signi…

AdultMalemedicine.medical_specialtySympathetic Nervous SystemPhysiologyPeriod (gene)PostureRR intervalBlood PressureBaroreflexHeart RateTilt-Table TestCoherence and transfer functionFeedback and feedforward mechanismPhysiology (medical)Internal medicineHumansMedicineDirectionalityNonbaroreflex interactionFeedback Physiologicalbusiness.industryModels CardiovascularCardiovascular regulationHeartVagus NerveBaroreflexBlood pressureCirculatory systemCardiologySystolic arterial pressureFemaleCross-spectral analysiCardiology and Cardiovascular MedicinebusinessClosed loopAmerican Journal of Physiology-Heart and Circulatory Physiology
researchProduct