Search results for "Color doppler"

showing 10 items of 21 documents

Two-dimensional and three-dimensional sonography of conjoined twins.

2002

Purpose The aim of this study was to evaluate and compare the diagnostic capabilities of 2-dimensional (2D) and 3-dimensional (3D) sonography for the study of conjoined twins. Methods Four pregnant women with an initial 2D sonographic diagnosis of conjoined twins were examined with color Doppler sonography, 3D multiplanar sonography, and orthogonal plane imaging and 3D surface rendering. Results All 4 cases of conjoined twins were initially diagnosed with either transvaginal or transabdominal 2D sonography. 3D sonography afforded more realistic views and demonstrated more clearly the linking areas and surface anomalies, but 2D and color Doppler sonography provided more definitive and specif…

3d sonographyAdultMalemedicine.medical_specialty3 dimensional ultrasonographybusiness.industryOrthogonal planeUltrasoundInfant NewbornColor dopplermedicine.diseaseSurgeryPregnancyConjoined twinsmedicineHumansRadiology Nuclear Medicine and imagingSurface renderingFemaleRadiologyUltrasonographyUltrasonography Doppler ColorbusinessTwins ConjoinedUltrasonographyJournal of clinical ultrasound : JCU
researchProduct

Color doppler ultrasonography of soft-tissue masses

1998

Purpose: To evaluate the capability of color Doppler ultrasonography to differentiate between benign and malignant soft-tissue tumors. Material and Methods: We reviewed the ultrasonographic (US) and color Doppler (CD) findings in 46 consecutive patients with a palpable periskeletal mass. The presence of 3 or more vascular hila and of tortuous and irregular internal vessels within the lesions was considered an indication of malignancy. The CD diagnosis was compared with that obtained at US alone. Results: The sensitivity and specificity of CD were respectively 85% and 92%; these values were higher than those obtained at US alone, respectively 75% and 50%. Arteriovenous malformations present…

AdultMalemedicine.medical_specialtyAdolescentDiagnostico diferencialSoft Tissue NeoplasmsMalignancySensitivity and SpecificityDiagnosis Differentialsymbols.namesakeColor doppler ultrasonographyHumansMedicineFalse Positive ReactionsRadiology Nuclear Medicine and imagingUltrasonography Doppler ColorChildFalse Negative ReactionsAgedRadiological and Ultrasound Technologybusiness.industrySoft tissueGeneral MedicineColor dopplerMiddle Agedmedicine.diseaseUltrasonography Doppler PulsedChild PreschoolsymbolsVascular impedanceFemaleRadiologyUltrasonographybusinessDoppler effectActa Radiologica
researchProduct

Extracranial Venous Drainage Pattern in Multiple Sclerosis and Healthy Controls: Application of the 2011 Diagnostic Criteria for Chronic Cerebrospina…

2015

The etiology of multiple sclerosis (MS) is still largely unknown and it has been proposed that an impaired venous drainage from the central nervous system, defined as chronic cerebrospinal venous insufficiency (CCSVI), may play a role in this. We investigated the prevalence of extracranial venous drainage pattern alterations in a cohort of MS patients based on the 2011 revised diagnostic criteria for CCSVI. Thirty-nine MS patients and 18 healthy subjects underwent blinded extra-cranial venous echo-color Doppler sonography to reveal the presence of CCSVI. There was no statistically significant difference between MS patients and healthy controls regarding CCSVI prevalence (p value = 0.53). Th…

AdultMalemedicine.medical_specialtyNeurologyChronic cerebrospinal venous insufficiencyUltrasonography Doppler TranscranialTranscranial030204 cardiovascular system & hematologyPathogenesisMultiple sclerosis03 medical and health sciences0302 clinical medicineEcho-color Doppler sonographyInternal medicineCerebral venous outflow; Chronic cerebrospinal venous insufficiency; Echo-color Doppler sonography; Multiple sclerosis; Neurology (clinical); NeurologymedicinePrevalenceHumansUltrasonographybusiness.industryMultiple sclerosisDopplerVenous drainageMiddle Agedmedicine.diseaseSurgerySettore MED/26 - NEUROLOGIADoppler sonographyChronic cerebrospinal venous insufficiencyVenous InsufficiencyNeurologyCase-Control StudiesCohortEtiologyCardiologyFemaleNeurology (clinical)Cerebral venous outflowbusiness030217 neurology & neurosurgery
researchProduct

Is avoidance of surgery possible in patients with perimenopausal ovarian tumors using transvaginal ultrasound and duplex color Doppler sonography?

1993

A total of 108 cases of small perimenopausal ovarian tumors (largest diameter, less than 7 cm) were evaluated by transvaginal sonography and duplex color Doppler sonography; 101 had criteria for benignity and 7 for malignancy. All cysts were punctured and aspirated to avoid unnecessary surgery (benign cases) and establish the cytologic diagnosis as well as to avoid the risk of leakage (malignant cases). Recurrence rate of benign punctured cysts was 25% within 1 year of follow up. No difference in recurrent rate was seen between pre- and postmenopausal patients (19 of 56 cases in the premenopausal group, and five of 28 cases in the postmenopausal group). The larger the cyst, the greater the …

Adultmedicine.medical_specialtyPuncturesSuctionMalignancyDiagnosis DifferentialRecurrencemedicineHumansRadiology Nuclear Medicine and imagingIn patientCystAgedUltrasonographyOvarian NeoplasmsRadiological and Ultrasound Technologybusiness.industryBenignityBiopsy NeedleUltrasoundColor dopplerMiddle Agedmedicine.diseaseSurgeryMenopauseOvarian CystsBloodDuplex (building)FemaleMenopausebusinessFollow-Up StudiesJournal of Ultrasound in Medicine
researchProduct

ASSOCIATION BETWEEN RENAL RESISTIVE INDEX AND CAROTID INTIMA-MEDIA THICKNESS IN HYPERTENSIVE PATIENTS.

2013

Introduction: The assessment of renal hemodynamic parameters by duplex Doppler sonography has been used for many years as a diagnostic tool in the daily work-up of kidney diseases. Recent data suggest that these parameters, especially the intrarenal resistive index (RI) may be also associated with changes of the systemic vascular tree and with an enhanced cardiovascular risk. However, conflicting data exist in literature about the independent association of carotid intima-media thickness (IMT) with RI. Aim: To evaluate the relationship between RI and carotid IMT in the hypertensive subjects consecutively attending our hypertension centre. Methods: We enrolled 264 subjects, aged between 30 a…

Carotid atherosclerosiRenal resistive indexEcho-color dopplerIntima media thickne
researchProduct

Role of Color Doppler Ultrasonography to Address the treatment of Epicondylitis with Mini-Invasive Techniques.

2008

Color Doppler Ultrasonography Epicondylitis
researchProduct

Color-Doppler Flow Mapping of the Heart in Normal Subjects

1988

Flow mappingbusiness.industryMedicineRadiology Nuclear Medicine and imagingColor dopplerCardiology and Cardiovascular MedicinebusinessBiomedical engineeringEchocardiography
researchProduct

Monitoring of fracture calluses with color Doppler sonography.

1999

Purpose Fracture callus formation is closely associated with vascular invasion, and the use of color Doppler sonography has been suggested as a means to monitor, earlier than gray-scale sonography, the first stages of the healing process. We report the findings in a series of patients with tibial fractures in whom both gray-scale sonography and color Doppler imaging were employed to monitor new bone formation at the fracture site. Methods Twenty patients with tibial fractures treated with external fixator frames were examined sonographically about 10 days after surgery and then about every 25 days until radiographic demonstration of consolidation. Results Eighteen of 20 patients had a well-…

Ilizarov TechniqueAdultMalemedicine.medical_specialtyAdolescentExternal FixatorsRadiographyBone healingIlizarov TechniqueSensitivity and SpecificityBone remodelingReference ValuesmedicineHumansRadiology Nuclear Medicine and imagingTibiaBony CallusUltrasonography Doppler ColorMonitoring PhysiologicFracture Healingbusiness.industryUltrasoundColor dopplerSurgeryTibial FracturesFracture (geology)FemaleRadiologybusinessFollow-Up StudiesJournal of clinical ultrasound : JCU
researchProduct

Does transvaginal color Doppler sonography differentiate between developing and involuting ectopic pregnancies?

1995

The objective of this study was to assess the addition of transvaginal color Doppler imaging to transvaginal ultrasonography and beta-human chorionic gonadotropin values to differentiate between developin and involuting ectopic pregnancies. Forty surgically confirmed ectopic pregnancies were classified into developing or involuting according to histopathologic findings. Results were compared retrospectively with the plasma beta-human chorionic gonadotropin values as well as the resistive index and pulsatility index obtained in corpora lutea and peritrophoblastic flow in serial examinations. Student's t-test was used for comparison of means. Logistic regression analysis was applied to predic…

Involution (mathematics)Adultendocrine systemmedicine.medical_specialtyAdolescentmedicine.drug_classChorionic GonadotropinUltrasonography PrenatalCorpus LuteumPregnancyMedicineHumansRadiology Nuclear Medicine and imagingStage (cooking)Ultrasonography Doppler Colorreproductive and urinary physiologyRetrospective StudiesGynecologyRadiological and Ultrasound TechnologyEctopic pregnancyurogenital systembusiness.industryObstetricsColor dopplermedicine.diseaseResistive indexPregnancy Ectopicmedicine.anatomical_structureVaginaGestationFemaleGonadotropinbusinessCorpus luteumBlood Flow VelocityJournal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
researchProduct

Color Doppler Ultrasound in Portal Hypertension

2020

Portal hypertension is one of the most important causes of morbidity and mortality in cirrhotic patients. A color Doppler evaluation of the left gastric vein (LGV) has proven utility in the prediction of esophageal varices and variceal bleeding in patients with portal hypertension. The purpose of this review is to discuss the ultrasound evaluation, imaging findings, and clinical application of Doppler ultrasound in the assessment of the LGV. Knowledge of the color Doppler technique and imaging findings of the LGV may help clinicians improve the monitoring of portal hypertension and predict patients with a high risk of esophageal varices.

Liver Cirrhosisesophageal varicemedicine.medical_specialtyleft gastric veinLeft gastric veinHemodynamicsEsophageal and Gastric Varicesurologic and male genital diseasesChronic liver disease030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineEsophageal varicesHypertension PortalHumansMedicineRadiology Nuclear Medicine and imagingUltrasonography Doppler Color030219 obstetrics & reproductive medicineRadiological and Ultrasound TechnologyPortal Veinultrasoundbusiness.industryUltrasoundHemodynamicschronic liver diseaseportal hypertensionColor doppler ultrasoundColor dopplermedicine.diseasefemale genital diseases and pregnancy complicationsPortal hypertensionRadiologycolor DopplerGastrointestinal HemorrhagebusinessJournal of Ultrasound in Medicine
researchProduct