Search results for "Computer-Assisted"
showing 10 items of 1186 documents
Reference Ranges and Distribution of Placental Volume by 3-Dimensional Virtual Organ Computer-Aided Analysis Between 11 Weeks and 13 Weeks 6 Days
2013
OBJECTIVES The purpose of this study was to determine the feasibility, reproducibility, and distribution of placental volume measurements according to the crown-rump length between 11 weeks and 13 weeks 6 days. METHODS Images were acquired in 128 pregnancies followed in Burgundy during first-trimester screening sonography using an abdominal 3-dimensional transducer. The placental volume was then calculated by the virtual organ computer-aided analysis method with a rotation angle of 30° by a single operator. RESULTS Placental volumes ranged from 33.3 to 107.6 cm(3) with a mean ± SD of 62.3 ± 14.8 cm(3); the 5th and 10th percentiles were 38.0 and 44.20 cm(3), respectively, whereas the 90th an…
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…
2010
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…
The Association between Dietary Habits, Substance Use, and Mental Distress among Adults in Southern Norway: A Cross-Sectional Study among 28,047 Adul…
2021
The aim of the present study was to examine associations between dietary habits, substance use, and mental distress among adults. This cross-sectional study was conducted in 2019 using an online questionnaire and included 28,047 adults (≥18 years) from Southern Norway. Multivariable logistic regression models stratified by gender were used to examine the associations between different lifestyle behaviors and mental distress. The results showed increased odds of mental distress among males and females with low consumption of vegetables (OR:1.26
Automatic Detection of Left Ventricular Contours from Cardiac Cine Magnetic Resonance Imaging Using Fuzzy Logic
1999
Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method.The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejecti…
Automatic determination of aortic compliance with cine-magnetic resonance imaging - An application of fuzzy logic theory
2002
International audience; Abstract: RATIONALE AND OBJECTIVES. Aortic compliance is defined as the relative change in aortic cross-sectional area divided by the change in arterial pressure. Magnetic resonance imaging (MRI) is a useful imaging modality for the noninvasive evaluation of aortic compliance. However, manual tracing of the aortic contour is subject to important interobserver variations. To estimate the aortic compliance from cine-MRI, a method based on fuzzy logic theory was elaborated. MATERIALS AND METHODS. Seven healthy volunteers and eight patients with Marfan syndrome were examined using an ECG gated cine-MRI sequence. The aorta was imaged in the transverse plane at the level o…
The internal calcar septum and its contact with the virtual stem in THR: a computer tomographic evaluation.
2003
The internal calcar septum is a ridge of cortical bone protruding from the inner cortical wall of the proximal femur into the medullary canal. It extends from the lesser trochanter into the femoral neck and narrows the femoral cavity in its dorsal third. This region is essential for THR stability, but the degree of contact between the septum and standard THR implants has never been studied. We obtained CT scans of 50 arthrotic hip joints from patients requiring THR. Virtual stems (50 straight/wedge-shaped and 50 anatomic stems) were placed in CT images of the femora using a PC-based preoperative planning unit. The dimensions of the septum, degree and location of contact between the septum a…
Hepatic Hilar and Sectorial Vascular and Biliary Anatomy in Right Graft Adult Live Liver Donor Transplantation
2008
Abstract Introduction The aim of this study was to analyze vascular and biliary variants at the hilar and sectorial level in right graft adult living donor liver transplantation. Methods From January 2003 to June 2007, 139 consecutive live liver donors underwent three-dimensional computed tomography (3-D CT) reconstructions and virtual 3-D liver partitioning. We evaluated the portal (PV), arterial (HA), and biliary (BD) anatomy. Results The hilar and sectorial biliary/vascular anatomy was predominantly normal (70%–85% and 67%–78%, respectively). BD and HA showed an equal incidence (30%) of hilar anomalies. BD and PV had a nearly identical incidence of sectorial abnormalities (64.7% and 66.2…
Macular edema computer-aided evaluation in ocular vein occlusions.
1998
This paper is concerned with the use of digital fundus imaging to detect, quantify, and follow up macular angiographic leakage due to retinal vein occlusions. Images were matched automatically. We detected those pixels with a high increment in gray level within the closest area to the foveal center. Binary images displaying leakage were obtained. The procedure was checked against two observers' agreement. Twenty-one angiographic studies were collected. Two images of each sequence were selected for digitalization. Numerical descriptors of the leakage were proposed and quantification plots were designed for each pair of images. Interobserver concordance ranged between 82 and 98% when manually…
OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers
2011
PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…
The accuracy and reproducibility of the endometrial receptivity array is superior to histology as a diagnostic method for endometrial receptivity
2013
Objective To compare the accuracy and reproducibility of the endometrial receptivity array (ERA) versus standard histologic methods. Design A comparative prospective study (May 2008–May 2012). Setting University-affiliated infertility clinic. Patient(s) Eighty-six healthy oocyte donors, regularly cycling, aged 20–34 years with a body mass index (BMI) of 19–25 kg/m 2 . Intervention(s) Endometrial biopsies were collected throughout the menstrual cycle. For the accuracy study, 79 samples were grouped into two cohorts: the training set (n = 79) for ERA machine-learning training and dating, and a dating subset (n = 49) for comparison between histologic and ERA dating. For the reproducibility stu…