Search results for "Computer-Assisted"
showing 10 items of 1186 documents
Endo-neuro-sonography: principles and 3-D technique
1997
To evaluate the usefulness of transendoscopic sonography we studied two new sono probes 6 F in diameter in 17 fresh specimens. We saw precise imaging of well-known anatomical structures and also gained an additional dimension in endoscopy, as the sono adds to the endo-view a transverse scan like a mini-CT at the tip of the probe. We also experienced the navigation characteristic of this imaging technique, both in real time and on line. Some 3-D reconstructions of the ventricular system were examined. The equipment has been used in clinical practice and must now be adapted for neurosurgery.
Virtual reality treatment of claustrophobia: a case report.
1998
The efficacy of a treatment for claustrophobia using only Virtual Reality (VR) exposure was examined. The subject was a 43-year-old female who suffered from clinically significant distress and impairment and sought psychological therapy. Eight individual VR graded exposure sessions were conducted. All self-report measures were reduced following VR exposure and were maintained at one month follow-up. The necessity of a theoretical framework for this new medium for exposure therapy is discussed.
Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.
2015
To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…
A New Systematic Classification of Peripheral Anatomy of the Right Hepatic Duct: Experience From Adult Live Liver Donor Transplantation
2008
Abstract Objective The peripheral intrahepatic biliary anatomy, especially at the sectorial level on the right side, has not been adequately described. The purpose of our study was to systematically describe this complex anatomy in clinically applicable fashion. Patients and Methods We analyzed three-dimensional computed tomography (CT) imaging reconstructions of 139 potential living liver donors evaluated at our institution between January 2003 and June 2007. Results Eighty-nine (64%) donors had a normal right bile duct sectorial anatomy. In the other 50/139 (36%) cases, we observed abnormal sectorial branching patterns, with 45/50 abnormalities as trifurcations, whereas the remaining ones…
The use of computer-assisted video image analysis for the quantification of CD8+ T lymphocytes producing tumor necrosis factor alpha spots in respons…
1997
Enzyme-linked immunospot (ELISPOT) analysis is a sensitive technique for the detection and quantification of single T lymphocytes forming cytokine spots after antigen contact in vitro. Herein computer-assisted video image analysis (CVIA) was applied to automatically determine the number and size of tumor necrosis factor alpha (TNF-alpha) spots formed by single blood-derived CD8+ T cells after contact with peptide-loaded target cells. With CVIA and TNF-alpha ELISPOT analysis we quantified CD8+ T cells responsive to HLA-A2.1-binding tyrosinase and influenza matrix peptides in healthy donors. We followed the course of the virus-specific T cell response in two HLA-A2-positive patients with reac…
Multicenter validation of the magnetic resonance t2* technique for segmental and global quantification of myocardial iron
2009
Purpose To assess the transferability of the magnetic resonance imaging (MRI) multislice multiecho T2* technique for global and segmental measurement of iron overload in thalassemia patients. Materials and Methods Multiecho T2* sequences were installed on six MRI scanners. Five healthy subjects (n = 30) were scanned at each site; five thalassemia major (TM) patients were scanned at the reference site and were rescanned locally (n = 25) within 1 month. T2* images were analyzed using previously validated software. Results T2* values of healthy subjects showed intersite homogeneity. On TM patients, for global heart T2* values the correlation coefficient was 0.97, coefficients of variation (CoV…
Stakeholders? views on online interventions to prevent common mental health disorders in adults implemented into existing healthcare systems in Europe
2021
Abstract Background Online preventive interventions can help to reduce the incidence of mental disorders. Whereas knowledge on stakeholders’ attitudes and factors relevant for successfully integrating online treatment into existing healthcare systems is available, knowledge is scarce for online prevention. Methods Stakeholders from Germany, Switzerland, Austria and Spain were surveyed. Potential facilitators/delivery staff (e.g. psychologists, psychotherapists) completed an online questionnaire (n = 183), policy makers (i.e. from the governing sector or health insurance providers) participated in semi-structured interviews (n = 16) and target groups/potential users of mental illness prevent…
Quantifying stenosis in renal arteriograms: a fuzzy syntactic analysis.
1999
AbstractThe introduction of fuzzy logic improves a system for the automatic quantification of renal artery lesions seen in digital subtraction angiograms. A two-step approach has been followed. An earlier system based on non-fuzzy syntactic analysis provided a clear symbolic description of the stenotic lesions. Although this system worked correctly, it did not take into account the variability and uncertainty inherent to image processing and to knowledge on the reference diameter. This system has been improved by the introduction of fuzzy logic in the representation of the reference diameter. It provides a description of the stenosis in terms of fuzzy quantities. To illustrate the benefits …
Progress in electron microscopic diagnostics: semi-quantitative determination of precipitable calcium in different cell types of the organ of Corti i…
1991
Potassium antimonate was used to precipitate calcium in the cochlea of the guinea-pig. The distribution of the calcium antimonate precipitates was analysed by electron microscopy. The precipitate density was determined in different cell types in the organ of Corti by counting the number of calcium binding sites in a 10-micron 2 area. The size of the precipitates varied considerably, and thus the relative amount of the precipitable calcium was estimated only semi-quantitatively. As the prominent carbon signal is superimposed over the nearby small Ca(2+)-edge signals, the combined signal of the antimony M4,5-edge and the oxygen K-edge of the calcium antimonate salt formed was chosen for the s…
Use of electron spectroscopic imaging to determine element composition of the melanin granules in the stria vascularis of the guinea pig.
1998
Electron spectroscopic imaging (ESI) was used to analyze the element content of melanin granules in the stria vascularis seen in ultrathin sections of Spurr-embedded cochleae of the guinea pig. To determine element composition, ESI images were taken at different ionization edges, and non-specific background signals were subtracted digitally by an image processing system. The presence of calcium and nitrogen in the melanin granules could be demonstrated clearly. The calcium identified in the melanin granules was then compared with the spatial distributions of calcium binding sites after the application of an antimonate precipitation method, which was used to localize loosely bound calcium. D…