Search results for "Computer-assisted"

showing 10 items of 1186 documents

Artefacts in CBCT: a review

2011

Artefacts are common in today's cone beam CT (CBCT). They are induced by discrepancies between the mathematical modelling and the actual physical imaging process. Since artefacts may interfere with the diagnostic process performed on CBCT data sets, every user should be aware of their presence. This article aims to discuss the most prominent artefacts identified in the scientific literature and review the existing knowledge on these artefacts. We also briefly review the basic three-dimensional (3D) reconstruction concept applied by today's CBCT scanners, as all artefacts are more or less directly related to it.

medicine.medical_specialtyCone beam computed tomographyComputer scienceMetal artefactImage processingReviewImaging Three-DimensionalScattering radiationImage Processing Computer-AssistedmedicineHumansScattering RadiationRadiology Nuclear Medicine and imagingMedical physicsComputer visionGeneral DentistryCone beam ctPhantoms Imagingbusiness.industryGeneral MedicineCone-Beam Computed TomographyModels TheoreticalRadiographic Image EnhancementOtorhinolaryngologyArtificial intelligenceArtifactsbusinessAlgorithmsDentomaxillofacial Radiology
researchProduct

Variations in acoustical beam properties of intracoronary Doppler catheters.

1993

The limitations of coronary angiography in assessing the functional significance of coronary obstructions is well known. While the critical variable of coronary blood flow cannot be readily measured, intraluminal Doppler sonography offers useful related functional information on blood flow velocity. In order to fully evaluate Doppler signals it is essential to have exact knowledge of the transducer transmission characteristics and of the ultrasound beam topology. In an experimental set-up, the transmitter-receiver characteristics of five commonly used Doppler catheters were investigated. In comparing the beam characteristics we found inhomogeneities in the lateral beam spread. At a penetrat…

medicine.medical_specialtyCoronary DiseaseSignalsymbols.namesakeCoronary CirculationComputer GraphicsMedicineHumansComputer SimulationAngioplasty Balloon CoronaryUltrasonography Interventionalbusiness.industryUltrasoundModels CardiovascularSignal Processing Computer-AssistedBlood flowEquipment DesignLaser Doppler velocimetryEchocardiography DopplerTransducersymbolsUltrasonic sensorRadiologyCardiology and Cardiovascular MedicinebusinessDoppler effectBeam (structure)Blood Flow VelocityBiomedical engineeringCatheterization and cardiovascular diagnosis
researchProduct

Cost-effectiveness analysis of robot-assisted vs. open partial nephrectomy

2017

Background The cost-effectiveness of robot-assisted partial nephrectomy (RAPN) vs. the open procedure is not established. Methods We estimated in-hospital complications and the cost of RAPN vs. open partial nephrectomy (OPN) using an economic model. Costs incurred both intraoperatively and in hospital were considered. US data were extracted from existing literature. Results Mean in-hospital costs were $14,824 (95% CI $13,368-$16,898) for RAPN and $15,094 (95% CI $13,491-$17,140) for OPN. Complications after RAPN occurred in 23.3% (95% CI 20.0-25.8%) and after OPN in 36.1% (95% CI 35.6-36.6%) of the patients. In a sensitivity analysis, limited centre experience was associated with relevant i…

medicine.medical_specialtyCost-Benefit Analysismedicine.medical_treatment030232 urology & nephrologyBiophysicsNephrectomy03 medical and health sciencesPostoperative Complications0302 clinical medicineRobotic Surgical ProceduresmedicineHumansOpen partial nephrectomyHospital CostsComputer-assisted surgerybusiness.industryDecision TreesPerioperativeCost-effectiveness analysisNephrectomyComputer Science ApplicationsSurgeryModels EconomicTreatment Outcome030220 oncology & carcinogenesisSurgeryLower costbusinessThe International Journal of Medical Robotics and Computer Assisted Surgery
researchProduct

A fully automatic 2D segmentation method for uterine fibroid in MRgFUS treatment evaluation

2015

PurposeMagnetic Resonance guided Focused UltraSound (MRgFUS) represents a non-invasive surgical approach that uses thermal ablation to treat uterine fibroids. After the MRgFUS treatment, an operator must manually segment the treated fibroid areas to evaluate the NonPerfused Volume (NPV). This manual approach is operator-dependent, introducing issues of result reproducibility, which could lead to errors in the subsequent follow-up phase. Moreover, manual segmentation is time-consuming, and can have a negative impact on the optimization of both machine-time and operator-time. MethodTo address these issues, in this paper a novel fully automatic method based on the unsupervised Fuzzy C-Means cl…

medicine.medical_specialtyDatabases FactualUterine fibroidsComputer scienceAdaptive thresholdingImage ProcessingAdaptive thresholding; Automatic segmentation; Fuzzy C-Means clustering; MRgFUS treatment; Uterine fibroids; Female; Humans; Image Processing Computer-Assisted; Leiomyoma; Radiography; Algorithms; Databases Factual; Magnetic Resonance Imaging; Ultrasonography InterventionalHealth InformaticsFuzzy logicDatabasesComputer-AssistedImage Processing Computer-AssistedmedicineHumansSegmentationCluster analysisFactualUltrasonography InterventionalUltrasonographySettore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniInterventionalLeiomyomaPixelbusiness.industryPattern recognitionmedicine.diseaseMagnetic Resonance ImagingFuzzy C-Means clusteringComputer Science ApplicationsSurgeryRadiographyTreatment evaluationMRgFUS treatmentFully automaticFemaleManual segmentationArtificial intelligenceAutomatic segmentationAdaptive thresholding Automatic segmentation Fuzzy C-Means clustering MRgFUS treatment Uterine fibroidsbusinessAlgorithmsUterine fibroids
researchProduct

Histometric investigations of placental villi in cases of unexpected fetal acidosis.

1994

It is not unusual that, after an apparently uneventful pregnancy and birth, postpartal analysis of fetal blood unexpectedly reveals the presence of peripartal acidosis, a finding that is inexplicable on the basis of routine observation of the placenta. Using computer-assisted histometric procedures, it is possible to make a quantitative assessment with respect to the maturity and differentiation of villi, thus casting light on the functional anatomy of these structures. 89 single-birth pregnancies were grouped in accordance to the pH of blood in the umbilical artery (pre-acidosis, acidosis, non acidotic). In acidotic newborns, there is an absolute reduction in the surface area of the placen…

medicine.medical_specialtyFetal acidosisPlacentaPhysiologyPathogenesisFetal Organ MaturityPregnancyInternal medicinePlacentamedicine.arterymedicineHumansDiagnosis Computer-AssistedMaternal-Fetal ExchangeAcidosisFetusPregnancybusiness.industryHistological TechniquesInfant NewbornObstetrics and GynecologyUmbilical arterymedicine.diseaseFetal Diseasesmedicine.anatomical_structureEndocrinologyPediatrics Perinatology and Child HealthChorionic villiFemalemedicine.symptomChorionic VillibusinessAcidosisJournal of perinatal medicine
researchProduct

Discrimination of early/intermediate and advanced/complicated coronary plaque types by radiofrequency intravascular ultrasound analysis

2002

Radiofrequency intravascular ultrasound (IVUS-RF) analysis, as an extension of conventional IVUS imaging, may provide more accurate plaque discrimination. Thirty-two autopsy atherosclerotic coronary arteries were investigated. Corresponding sectors in different plaques were matched by histologic and RF analysis. Histologic analysis utilized the American Heart Association plaque classification. The backscattered ultrasound RF signal was analyzed by fast-Fourier transform, providing the underlying frequency components of its power spectrum. The normalized backscattered signal power (in decibels [dB]) for frequencies between 15.3 and 40.3 MHz was then measured for plaque discrimination. Advanc…

medicine.medical_specialtyFourier Analysismedicine.diagnostic_testbusiness.industryUltrasoundSpectral densityCoronary Artery DiseaseCoronary VesselsSensitivity and SpecificitySignalCoronary arteriesmedicine.anatomical_structureCoronary plaqueIntravascular ultrasoundCadaverImage Processing Computer-AssistedmedicineHumansRadio frequencyRadiologyCardiology and Cardiovascular MedicinebusinessUltrasonography InterventionalDecibelThe American Journal of Cardiology
researchProduct

Studying hypertension in ocular fundus images using Hausdorff dispersion ordering.

2010

Retinal arterial and vein diameters are altered in individuals at risk of cardiovascular events mainly due to high blood pressure. The measurement of retinal vessel diameters has been proved to reflect individuals' vascular health. Dispersion of such measures which are obtained by means of ocular fundus images is a major factor not usually considered in clinical research. In this paper, a method to evaluate if different levels of clinically relevant covariables induce greater dispersion in retinal arterial and vein diameters is proposed. A multivariate dispersion ordering, the Hausdorff dispersion order, is used to compare the level of dispersion in such diameters for different groups of pa…

medicine.medical_specialtyFundus OculiGeneral Biochemistry Genetics and Molecular BiologyRetinaVascular healthchemistry.chemical_compoundOphthalmologymedicineImage Processing Computer-AssistedHumansStatistical dispersionVeinGeneral Environmental SciencePharmacologyGeneral Immunology and Microbiologybusiness.industryApplied MathematicsGeneral NeuroscienceRetinal VesselsRetinalGeneral MedicineRetinal vesselBlood pressuremedicine.anatomical_structurechemistryHomogeneousModeling and SimulationHypertensionbusinessMathematical medicine and biology : a journal of the IMA
researchProduct

Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning

2008

Purpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the cathete…

medicine.medical_specialtyGenital Neoplasms Femalebusiness.industryRadiotherapy Planning Computer-AssistedSlice thicknessmedicine.medical_treatmentBrachytherapyBrachytherapyRadiotherapy DosageHematologyMagnetic Resonance ImagingCatheterizationCatheterOncologymedicineHumansDosimetryFemaleRadiology Nuclear Medicine and imagingRadiologyNuclear medicinebusinessRadiation treatment planningT2 weighted
researchProduct

Multimodality 3-dimensional volumetric ultrasound in obstetrics and gynecology with an emphasis in HDlive technique.

2013

HDlive (high-definition live or real-time US), a new ultrasound software, combines a movable virtual adjustable light source in a software that calculates the proportion of light reflecting through surface structures, depending on light direction. The light source can be manually positioned to illuminate the desired area of interest. The ultrasound technician can control light intensity to create shadows that enhance image quality. HDlive is an innovation that will render even more realistic images of fetal anatomy and of gynecologic lesions. The full potential of this new technology is yet to be determined and deserves scientific evaluation.

medicine.medical_specialtyImage qualityMultimodal ImagingMultimodalitySoftwareLight sourceObstetrics and gynaecologyComputer SystemsPregnancyImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingComputer visionDiagnostic Techniques Obstetrical and GynecologicalUltrasonographybusiness.industryEmphasis (telecommunications)UltrasoundImage EnhancementObstetric Labor ComplicationsLight intensityFemaleRadiologyArtificial intelligencebusinessGenital Diseases FemaleSoftwareUltrasound quarterly
researchProduct

Automatic detection of lung nodules in CT datasets based on stable 3D mass–spring models

2012

We propose a computer-aided detection (CAD) system which can detect small-sized (from 3 mm) pulmonary nodules in spiral CT scans. A pulmonary nodule is a small lesion in the lungs, round-shaped (parenchymal nodule) or worm-shaped (juxtapleural nodule). Both kinds of lesions have a radio-density greater than lung parenchyma, thus appearing white on the images. Lung nodules might indicate a lung cancer and their early stage detection arguably improves the patient survival rate. CT is considered to be the most accurate imaging modality for nodule detection. However, the large amount of data per examination makes the full analysis difficult, leading to omission of nodules by the radiologist. We…

medicine.medical_specialtyLung NeoplasmsDatabases FactualHealth InformaticsCADModels BiologicalSensitivity and SpecificityImaging Three-DimensionalSegmentationLung nodulemedicineFalse positive paradoxSegmentation; Lung nodules; Active contours models;Computer tomography (CT); Mass–spring models; Spline curves; Image featuresHumansSegmentationDiagnosis Computer-AssistedStage (cooking)Lung cancerComputer tomography (CT)business.industryNodule (medicine)Image featuresSpline curvemedicine.diseaseSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Computer Science ApplicationsRegion growingMass–spring modelRadiologyTomographymedicine.symptombusinessTomography Spiral ComputedAlgorithmsActive contours model
researchProduct