Search results for "Computer-assisted"
showing 10 items of 1186 documents
Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.
2011
Objectives The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients. Materials and methods In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer ac…
Spontaneous confabulation, temporal context confusion and reality monitoring: a study of three patients with anterior communicating artery aneurysms.
2010
AbstractSpontaneous confabulation involves the production of false or distorted memories, and is commonly associated with ventromedial prefrontal damage. One influential theory proposes that the critical deficit is a failure to suppress currently irrelevant memory traces that intrude into ongoing thinking (Schnider & Ptak, 1999). In this study, we report experimental investigations with three spontaneously confabulating patients aimed at exploring this account. Using Schnider and Ptak’s (1999) continuous recognition paradigm, we replicated their experimental results with our patients. However, our data suggest that the critical impairment might be more generalized than a failure to supp…
Reproducibility of CT Radiomic Features within the Same Patient: Influence of Radiation Dose and CT Reconstruction Settings.
2019
Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the reproducibility of radiomic features, as well as to identify correction factors for mitigating these sources of variability. Materials and Methods This was a secondary analysis of a prospective study of metastatic liver lesions in patients who underwent staging with single-energy dual-source contrast material-enhanced staging CT between September 2011 and April 2012. Technique p…
Quantification of epicardial adipose tissue in coronary calcium score and CT coronary angiography image data sets: comparison of attenuation values, …
2016
The aim of the study was to compare epicardial adipose tissue (EAT) characteristics assessed with coronary calcium score (CS) and CT coronary angiography (CTCA) image data sets.In 76 patients (mean age 59 ± 13 years) who underwent CS and CTCA owing to suspected coronary artery disease (CAD), EAT was quantified in terms of density (Hounsfield units), thickness and volume. The EAT volume was extracted with a semi-automatic software.A moderate correlation was found between EAT density in CS and CTCA image data sets (-100 ± 19 HU vs -70 ± 24 HU; p 0.05, r = 0.55). The distribution of EAT was not symmetrical with a maximal thickness at the right atrioventricular groove (14.2 ± 5.3 mm in CS, 15.…
Comparison of Diffusion MRI Acquisition Protocols for the In Vivo Characterization of the Mouse Spinal Cord: Variability Analysis and Application to …
2016
Diffusion-weighted Magnetic Resonance Imaging (dMRI) has relevant applications in the microstructural characterization of the spinal cord, especially in neurodegenerative diseases. Animal models have a pivotal role in the study of such diseases; however, in vivo spinal dMRI of small animals entails additional challenges that require a systematical investigation of acquisition parameters. The purpose of this study is to compare three acquisition protocols and identify the scanning parameters allowing a robust estimation of the main diffusion quantities and a good sensitivity to neurodegeneration in the mouse spinal cord. For all the protocols, the signal-to-noise and contrast-to noise ratios…
Deep Learning Techniques for Automatic MRI Cardiac Multi-Structures Segmentation and Diagnosis: Is the Problem Solved?
2018
Delineation of the left ventricular cavity, myocardium, and right ventricle from cardiac magnetic resonance images (multi-slice 2-D cine MRI) is a common clinical task to establish diagnosis. The automation of the corresponding tasks has thus been the subject of intense research over the past decades. In this paper, we introduce the “Automatic Cardiac Diagnosis Challenge” dataset (ACDC), the largest publicly available and fully annotated dataset for the purpose of cardiac MRI (CMR) assessment. The dataset contains data from 150 multi-equipments CMRI recordings with reference measurements and classification from two medical experts. The overarching objective of this paper is to measure how f…
Discrimination of retinal images containing bright lesions using sparse coded features and SVM
2015
Diabetic Retinopathy (DR) is a chronic progressive disease of the retinal microvasculature which is among the major causes of vision loss in the world. The diagnosis of DR is based on the detection of retinal lesions such as microaneurysms, exudates and drusen in retinal images acquired by a fundus camera. However, bright lesions such as exudates and drusen share similar appearances while being signs of different diseases. Therefore, discriminating between different types of lesions is of interest for improving screening performances. In this paper, we propose to use sparse coding techniques for retinal images classification. In particular, we are interested in discriminating between retina…
Distributed analysis of simultaneous EEG-fMRI time-series: modeling and interpretation issues
2009
Functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) represent brain activity in terms of a reliable anatomical localization and a detailed temporal evolution of neural signals. Simultaneous EEG-fMRI recordings offer the possibility to greatly enrich the significance and the interpretation of the single modality results because the same neural processes are observed from the same brain at the same time. Nonetheless, the different physical nature of the measured signals by the two techniques renders the coupling not always straightforward, especially in cognitive experiments where spatially localized and distributed effects coexist and evolve temporally at different …
Comparative studies on check-bite and central-bearing-point method for the remounting of complete dentures
1995
Thirty-six complete dentures were remounted both with check-bite as well as central-bearing-point (CBP) registration. The mandibular or denture position was registered in the condylar area three times with each method. Two independent operators carried out the registrations. One half of patients had their occlusion equilibrated according to the check-bite registration, the other half in the central-bearing-point position. After individual determination of the hinge axis the upper dentures were mounted by a face-bow transfer into a Dentatus articulator. A total of six registrations was performed and repeatedly compared in the condylar area in three dimensions using a computer supported measu…
The Full Revasc (Ffr-gUidance for compLete non-cuLprit REVASCularization) Registry-based randomized clinical trial
2021
Publisher Copyright: © 2021 Background: Complete revascularization in ST elevation myocardial infarction (STEMI) patients with multivessel disease has resulted in reduction in composite clinical endpoints in medium sized trials. Only one trial showed an effect on hard clinical endpoints, but the revascularization procedure was guided by angiographic evaluation of stenosis severity. Consequently, it is not clear how Fractional Flow Reserve (FFR)-guided percutaneous coronary intervention (PCI) affects hard clinical endpoints in STEMI. Methods and Results: The Ffr-gUidance for compLete non-cuLprit REVASCularization (FULL REVASC) – is a pragmatic, multicenter, international, registry-based rand…