Search results for "Comunicaciones"
showing 10 items of 175 documents
An analytical model to evaluate the radiated power spectrum of a multipactor discharge in a parallel-plate region
2008
This paper is aimed at studying the electromagnetic radiation pattern of a multipactor discharge occurring in a parallel-plate waveguide. The proposed method is based on the Fourier expansion of the multipactor current in terms of time-harmonic currents radiating in the parallel-plate region. Classical radiation theory combined with the frequency domain Green's function of the problem allows the calculation of both the electric and the magnetic radiated fields. A novel analytical formula for the total radiated power of each multipactor harmonic has been derived. This formula is suitable for predicting multipactor with the third-harmonic technique. The proposed formulation has been successfu…
Testing Equality of Multiple Power Spectral Density Matrices
2018
This paper studies the existence of optimal invariant detectors for determining whether P multivariate processes have the same power spectral density. This problem finds application in multiple fields, including physical layer security and cognitive radio. For Gaussian observations, we prove that the optimal invariant detector, i.e., the uniformly most powerful invariant test, does not exist. Additionally, we consider the challenging case of close hypotheses, where we study the existence of the locally most powerful invariant test (LMPIT). The LMPIT is obtained in the closed form only for univariate signals. In the multivariate case, it is shown that the LMPIT does not exist. However, the c…
La Europa social / 6. La implosión sindical
2005
Neutrino interaction classification with a convolutional neural network in the DUNE far detector
2020
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure CP-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electron neutrino (antineutrino) selection efficiency peaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between 2–5 GeV. The muon neutrino (antineutrino) event selection is found to have a maximum efficiency of 96% (97%) and exceeds 90% (95%) efficiency for reconstructed neutrino…
Scalable haloscopes for axion dark matter detection in the 30$\mu$eV range with RADES
2020
RADES (Relic Axion Detector Exploratory Setup) is a project with the goal of directly searching for axion dark matter above the 30μeV scale employing custom-made microwave filters in magnetic dipole fields. Currently RADES is taking data at the LHC dipole of the CAST experiment. In the long term, the RADES cavities are envisioned to take data in the BabyIAXO magnet. In this article we report on the modelling, building and characterisation of an optimised microwave-filter design with alternating irises that exploits maximal coupling to axions while being scalable in length without suffering from mode-mixing. We develop the mathematical formalism and theoretical study which justifies the perf…
MWP phase shifters integrated in PbS-SU8 waveguides
2015
[EN] We present new kind of microwave phase shifters (MPS) based on dispersion of PbS colloidal quantum dots (QDs) in commercially available photoresist SU8 after a ligand exchange process. Ridge PbS-SU8 waveguides are implemented by integration of the nanocomposite in a silicon platform. When these waveguides are pumped at wavelengths below the band-gap of the PbS QDs, a phase shift in an optically conveyed (at 1550 nm) microwave signal is produced. The strong light confinement produced in the ridge waveguides allows an improvement of the phase shift as compared to the case of planar structures. Moreover, a novel ridge bilayer waveguide composed by a PbS-SU8 nanocomposite and a SU8 passive…
Parallel Recording of Single Quantum Dot Optical Emission Using Multicore Fibers
2016
Single Indium Arsenide Quantum Dot emission spectra have been recorded using a four-core, crosstalk-free, multicore fiber placed at the collection arm of a confocal microscope. We developed two different measurement set-ups depending on the relative configuration of the excitation and collection spots. In the single-matched mode, the emission from the excited area is collected by a single core in the multicore fiber, whereas the three remaining cores capture the emission from neighboring, non-excited areas. This procedure allows for the recording of the Quantum Dot emission from carrier diffusion between sample positions separated by more than 6 μm. In the multiple-matched mode, the ex…
Design of compensated multiport waveguide junctions considering mechanization effects
2015
Abstract A new tool for the rigorous and efficient design of compensated multiport waveguide junctions, considering the mechanization effects due to low-cost manufacture techniques, is presented. Several new designs for a great variety of key components, present in modern microwave and millimetre-wave equipment, are proposed taking into account the introduction of rounded corners in the rectangular waveguide access ports. The new implemented tool permits to control and compensate for the potential degradation of the wide-band performance of such components prior to their fabrication, thus achieving an optimal design. All the presented results have been successfully validated by comparing th…
Noninvasive monitoring of polymer curing reactions by dielectrometry
2011
A microwave sensor system for the noninvasive monitoring of the curing process of a thermoset material placed inside a metallic mold is described. The microwave sensor is designed as an open-ended coaxial resonator with a curved surface adapted to the mold inner shape. The analysis of the microwave resonator comprises a recently developed method for deembedding the effect of coupling network in overcoupled resonators, so the range of permitted measurements encompass both low and high dielectric losses of polymeric materials. Results show that noninvasive, continuous monitoring of the microwave dielectric properties of the thermoset material can be performed in real time, allowing one to che…
Time of flight measurements based on FPGA using a breast dedicated PET
2014
In this work the implementation of a Time-to-Digital Converter (TDC) using a Nutt delay line FPGA-based and applied on a Positron Emission Tomography (PET) device is going to be presented in order to check the system’s suitability for Time of Flight (TOF) measurements. In recent years, FPGAs have shown great advantages for precise time measurements in PET. The architecture employed for these measurements is described in detail. The system developed was tested on a dedicated breast PET prototype, composed of LYSO crystals and Positive Sensitive Photomultipliers (PSPMTs). Two distinct experiments were carried out for this purpose. In the first test, system linearity was evaluated in order to …