Search results for "Cone-beam computed tomography"

showing 10 items of 90 documents

Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions

2014

Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…

AdultMalemedicine.medical_specialtyLung NeoplasmsInitial SeedAutomated segmentationBreast NeoplasmsTumor responseSensitivity and SpecificityMultidetector Computed TomographyImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationTumor growthAgedMathematicsAged 80 and overbusiness.industryLiver NeoplasmsPattern recognitionSpiral Cone-Beam Computed TomographyGold standard (test)Middle AgedTumor BurdenEffective diameterLiverKernel (statistics)FemaleArtificial intelligenceRadiologyColorectal NeoplasmsbusinessSoftwareRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Cone-beam computed tomography and its applications in dental and maxillofacial radiology.

2020

Cone-beam computed tomography (CBCT) was first used in dental and maxillofacial radiology (DMFR) at the end of the 1990s. Since then, it has been successfully established as the standard three-dimensional radiographic imaging technique in DMFR, with a wide variety of applications in this field. This manuscript briefly reviews the background information on the technology and summarises available data on effective dose and dose optimisation. In addition, typical clinical applications and indications of the technique in DMFR are presented.

Background informationCone beam computed tomographymedicine.medical_specialtymedicine.diagnostic_testRadiographic imagingbusiness.industryStomatognathic DiseasesComputed tomographyGeneral MedicineCone-Beam Computed TomographyRadiation DosageFacial Bones030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineImaging Three-Dimensional030220 oncology & carcinogenesismedicineMaxillaDose optimisationHumansRadiology Nuclear Medicine and imagingRadiologybusinessClinical radiology
researchProduct

A study on the reproducibility of cephalometric landmarks when undertaking a three-dimensional (3D) cephalometric analysis

2012

Objectives: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The first step must be to study the characteristics of these devices in terms of accuracy and reliability of the most commonly used landmarks. The aims were 1- To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2- To determine which of those landmarks are more vs. less reliable and 3- To introduce planes of reference so as to create cephalometric analyses appropriated to the 3D reality. Study design: Fifteen patients who h…

Cephalometric analysisAdultMaleAdolescentMedicinaCephalometryTomografiaDentistryDiagnostic toolsYoung AdultImaging Three-DimensionalClinical and Experimental DentistryMedicineHumansChildGeneral DentistryReliability (statistics)OrthodonticsObserver VariationReproducibilityLandmarkbusiness.industryReproducibility of ResultsCraniometryCone-Beam Computed Tomography:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryResearch-ArticleFemaleTomographybusinessMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Craniomaxillofacial morphology alterations in children, adolescents and adults with neurofibromatosis 1 : a cone beam computed tomography analysis of…

2017

Background Oral manifestations are common in neurofibromatosis 1 (NF1), and include jaws and teeth alterations. Our aim was to investigate the craniomaxillofacial morphology of Brazilian children, adolescents and adults with NF1 using cone beam computed tomography. Material and Methods This study was conducted with 36 Brazilian individuals with NF1 with ages ranging from 4 to 75. The participants were submitted to anamnesis, extra and intraoral exam and cephalometric analysis using cone beam computed tomography. Height of the NF1 individuals was compared to the length of jaws and skull base. The results of the cephalometric measurements of the NF1 group were compared with a control group pa…

Cephalometric analysisAdultMaleCone beam computed tomographycongenital hereditary and neonatal diseases and abnormalitiesNeurofibromatosis 1AdolescentCephalometry03 medical and health sciencesYoung Adult0302 clinical medicinestomatognathic systemmedicineHumansProspective StudiesNeurofibromatosisChildGeneral DentistryneoplasmsAgedAnamnesisOrthodonticsSkull BaseOral Medicine and Pathologybusiness.industryResearchMandible030206 dentistryCone-Beam Computed TomographyMiddle Aged:CIENCIAS MÉDICAS [UNESCO]medicine.diseasenervous system diseasesSkullstomatognathic diseasesmedicine.anatomical_structureOtorhinolaryngologyJawMaxillaCase-Control StudiesChild PreschoolUNESCO::CIENCIAS MÉDICASEarly adolescentsSurgeryFemalebusiness030217 neurology & neurosurgeryBrazil
researchProduct

The evaluation of changes in maxillofacial bones using cone beam tomography in acromegaly

2022

BACKGROUND: The aim of the study was to evaluate the changes in craniofacial dimensions of newly diagnosed and untreated acromegaly patients, patients with non-functional pituitary adenoma and healthy individuals on Cone Beam Computed Tomography (CBCT). MATERIAL AND METHODS: 50 newly diagnosed acromegaly patients who did not receive any treatment for acromegaly were included in the study (Group A). Twenty patients with nonfunctional pituitary adenoma (Group B) and 30 healthy individuals were included (Group C). Linear, angular and volumetric measurements were performed. RESULTS: Mandibular length showed significant difference in acromegaly patients, and maxillar length statistically signifi…

Cephalometrybcl-2MandibleCone-Beam Computed Tomographyki67OtorhinolaryngologybaxAcromegalyHumansgja1 rs12197797 genotypingPituitary NeoplasmsSurgeryimmunostaining expression profileGeneral Dentistrycx43e-cadherinUNESCO:CIENCIAS MÉDICAS
researchProduct

Influence of root width and dentin wall thickness evaluated by endoscopy upon the outcome of periapical surgery. A cohort study.

2020

Background: An analysis was made of the correlation between root width, the thickness of the remaining dentinal wall as determined by endoscopy, and the outcome of periapical surgery. Material and Methods: A retrospective cohort study was carried out involving patients subjected to periapical surgery between 2017 and 2019 at the University of Valencia (Valencia, Spain). One year after surgery, cone-beam computed tomography (CBCT) was used to evaluate healing against the preoperative volumes. The maximum root width was measured on the postoperative CBCT scan at the apical section of the treated root. This measurement was transferred to the intraoperative endoscopic image, where the minimum r…

Cirurgia oralCirurgia dentalEndoscopyCone-Beam Computed Tomographyhead and neckCohort StudiesOral surgeryOtorhinolaryngologyDental surgeryoncologyDentincancerHumansSurgeryoral cavityoropharynxEndoscòpiaDentinaTooth RootGeneral DentistryUNESCO:CIENCIAS MÉDICASRetrospective StudiesMedicina oral, patologia oral y cirugia bucal
researchProduct

Simple computation of the approximated modulation transfer function (MTF) using spreadsheet-software: method and evaluation in five maxillofacial CBC…

2019

OBJECTIVES: To develop a simple way to compute the approximated modulation transfer function (MTF) manually using conventional spreadsheet software. METHODS: Basing on an edge-image a method was developed, facilitating computation of the edge spread and line spread function in open-source spreadsheet software (Gnumeric; http://projects.gnome.org/gnumeric/downloads.shtml). By means of the integrated fast Fourier transformation Fourier coefficients are obtained from the line spread function which can then be plotted vs spatial frequency to obtain MTF-plots. For the experimental evaluation an edge test object was exposed in five commercial CBCT devices for maxillofacial applications. RESULTS: …

Computer science030218 nuclear medicine & medical imaging03 medical and health sciencessymbols.namesake0302 clinical medicineTechnical ReportSimple (abstract algebra)Optical transfer functionRadiography DentalHumansRadiology Nuclear Medicine and imagingGeneral DentistryDigital signal processingSimple computationbusiness.industrySpreadsheet softwarePhantoms ImagingComputer Science::Software EngineeringReproducibility of Results030206 dentistryGeneral MedicineSpiral Cone-Beam Computed TomographyRadiographic Image EnhancementFourier transformOtorhinolaryngologysymbolsbusinessAlgorithmSoftware
researchProduct

Automated detection of patient movement during a CBCT scan based on the projection data.

2015

Objectives To develop an automated procedure to detect patient motion on the projection images acquired during a cone beam computed tomography (CBCT) scan and to evaluate the method's feasibility on small real-world CBCT images in relation to visual assessment. Methods Based on optical flow theory, software was developed using the sequence of the projection images of a CBCT machine for automated detection of patient motion. Averaged acceleration vectors were used as measurement data and compared with visual assessment of the projection images displayed as video. Seventy-nine CBCT data sets (small field-of-view: 40 mm) from our patient database were selected in a sequential fashion and evalu…

Cone beam computed tomographyComputer scienceMovementOptical flowVideo RecordingSensitivity and SpecificityPathology and Forensic MedicineAccelerationSoftwareImaging Three-DimensionalHumansRadiology Nuclear Medicine and imagingDentistry (miscellaneous)Computer visionSensitivity (control systems)Projection (set theory)Pixelbusiness.industryPhantoms ImagingFrame (networking)Cone-Beam Computed TomographyFeasibility StudiesRadiographic Image Interpretation Computer-AssistedSurgeryArtificial intelligenceOral SurgerybusinessArtifactsAlgorithmsSoftwareOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Evaluation of lens absorbed dose with Cone Beam IGRT procedures

2015

The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v.1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to …

Cone beam computed tomographyDosimeterPhantoms Imagingbusiness.industryPublic Health Environmental and Occupational HealthTruebeamRadiotherapy DosageGeneral MedicineCone-Beam Computed Tomographyequipment and supplieslaw.inventionLens (optics)lawAbsorbed doseLens CrystallineThermoluminescent DosimetryMedicineThermoluminescent Dosimetrysense organsLaser beam qualitybusinessNuclear medicineHeadWaste Management and DisposalImage-guided radiation therapyJournal of Radiological Protection
researchProduct

Dental CBCT equipment and performance issues

2012

Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As a new imaging modality, there were no established suspension levels at a European level. A literature review, encompassing scientific, professional publications and existing national guidelines was performed in an attempt to develop a set of suspension levels for dental CBCT, using additional expert opinion from the members of the European Academy of dento-maxillo-facial radio…

Cone beam computed tomographyEuropean levelmedicine.medical_specialtyImage qualityComputer scienceGuidelines as TopicComputed tomographyRadiation DosageDental EquipmentImaging Three-DimensionalImage Processing Computer-AssistedRadiography DentalmedicineHumansRadiology Nuclear Medicine and imagingMedical physicsRadiometryRadiationModality (human–computer interaction)Radiological and Ultrasound Technologymedicine.diagnostic_testX-RaysDental EquipmentPublic Health Environmental and Occupational HealthTesting equipmentReproducibility of ResultsEquipment DesignGeneral MedicineCone-Beam Computed TomographyClinical Practicestomatognathic diseasesToothRadiation Protection Dosimetry
researchProduct