Search results for "Cone"
showing 10 items of 772 documents
Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manu…
2007
PURPOSE: The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. METHODS: Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range…
Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy
2006
The purpose of this study was to analyze three commercial siloxane-hydrogel contact lens materials, lotrafilcon A, balafilcon A, and galyfilcon A, by cryogenic scanning electron microscopy (cryoSEM). The fully hydrated lenses were frozen in slush liquid nitrogen and qualitatively observed in a cryogenic scanning electron microscope. The superficial ultrastructure of the siloxane-hydrogels was observed at the areas where the lens fractured during sample cryogenic preparation. There are qualitative differences among the three examined materials in the complex polymer network structure existing between the outer layer and the underlying polymer. CryoSEM, although destructive, is a useful tool …
Candida albicans biofilms on different materials for manufacturing implant abutments and prostheses
2019
[EN] Background: Morphological, physical and chemical properties of both implants and prostheses can determine the biofilm formation on their surface and increase the risk of biological complications. The aim of this study was to evaluate the capacity of biofilm formation of Candida albicans on different materials used to manufacture abutments and prostheses. Material and Methods: Biofilm formation was analyzed on cp grade II titanium, cobalt-chromium alloy and zirconia, silicone, acrylic resin (polymethylmethacrylate) and nano-hybrid composite. Some samples were partially covered with lithium disilicate glass ceramic to study specifically the junction areas. C. albicans was incubated in a …
Additive Manufacturing of Multi‐Scale Porous Soft Tissue Implants That Encourage Vascularization and Tissue Ingrowth
2021
Medical devices, such as silicone-based prostheses designed for soft tissue implantation, often induce a suboptimal foreign-body response which results in a hardened avascular fibrotic capsule around the device, often leading to patient discomfort or implant failure. Here, it is proposed that additive manufacturing techniques can be used to deposit durable coatings with multiscale porosity on soft tissue implant surfaces to promote optimal tissue integration. Specifically, the “liquid rope coil effect”, is exploited via direct ink writing, to create a controlled macro open-pore architecture, including over highly curved surfaces, while adapting atomizing spray deposition of a silicone ink t…
Long-term sealing ability of GuttaFlow versus Ah Plus using different obturation techniques.
2010
Objective. To compare the long-term sealing ability of GuttaFlow® using different obturation techniques. Study Design. Three hundred teeth, prepared with a crown-down technique, were divided into thirty experimental groups (n=10) to evaluate the apical and coronal leakage, at 3, 30 and 120 days, of lateral compaction gutta-percha + AH Plus?, lateral compaction gutta-percha + GuttaFlow®, single cone + AH Plus?, single cone + GuttaFlow®, and GuttaFlow® only. Results. Both coronal and apical leakage, at the three times of measurement, no significant differences were found among GuttaFlow® + lateral compaction gutta-percha and GuttaFlow® + single cone groups, whereas the only GuttaFlow® reached…
Sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel …
2011
Objectives: The aim of this study was to evaluate the sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium root canal instruments by fluid filtration method. Study design: The root canals were prepared with stainless steel (SS) and nickel titanium (NiTi) instruments. The canals prepared with SS were obturated with lateral compaction technique using .02 tapered cones and the canals prepared with NiTi instruments were obturated with lateral compaction technique using .02 tapered cones or 06 tapered single cones. The amount of leakage was evaluated by fluid filtration model. The results wer…
Adhesives and mounting media in aerobiological sampling
1989
Abstract Because microscopical identification and counting is vital in most aerobiological studies, pollen and spores are usually collected on some adhesive. The adhesives should not be water-soluble. For optically best results water-soluble mounting media with refractive indices about 1.40–1.45 are used. There are compatibility problems between water insoluble adhesives and watery mounting media. The former tend to move to stripes or droplets, distorting the image and moving the spores from their original positions. To solve this problem several adhesives based on silicone oils, silicone greases and vaseline or their mixtures were tested. The usual watery mounting media, glycerine gelatine…
Solving the Discrete Multiple Criteria Problem using Convex Cones
1984
An interactive method employing pairwise comparisons of attainable solutions is developed for solving the discrete, deterministic multiple criteria problem assuming a single decision maker who has an implicit quasi-concave increasing utility (or value) function. The method chooses an arbitrary set of positive multipliers to generate a proxy composite linear objective function which is then maximized over the set of solutions. The maximizing solution is compared with several solutions using pairwise judgments asked of the decision maker. Responses are used to eliminate alternatives using convex cones based on expressed preferences, and then a new set of weights is found that satisfies the i…
Blown-up toric surfaces with non-polyhedral effective cone
2020
We construct examples of projective toric surfaces whose blow-up at a general point has a non-polyhedral pseudo-effective cone, both in characteristic $0$ and in every prime characteristic $p$. As a consequence, we prove that the pseudo-effective cone of the Grothendieck-Knudsen moduli space $\overline M_{0,n}$ of stable rational curves is not polyhedral for $n\geq 10$ in characteristic $0$ and in characteristic $p$, for all primes $p$. Many of these toric surfaces are related to a very interesting class of arithmetic threefolds that we call arithmetic elliptic pairs of infinite order. Their analysis in characteristic $p$ relies on tools of arithmetic geometry and Galois representations in …
Sets with constant normal in Carnot groups: properties and examples
2019
We analyze subsets of Carnot groups that have intrinsic constant normal, as they appear in the blowup study of sets that have finite sub-Riemannian perimeter. The purpose of this paper is threefold. First, we prove some mild regularity and structural results in arbitrary Carnot groups. Namely, we show that for every constant-normal set in a Carnot group its sub-Riemannian-Lebesgue representative is regularly open, contractible, and its topological boundary coincides with the reduced boundary and with the measure-theoretic boundary. We infer these properties from a cone property. Such a cone will be a semisubgroup with nonempty interior that is canonically associated with the normal directio…