Search results for "Contract"

showing 10 items of 1719 documents

Design and validation of a neuroprosthesis for the treatment of upper limb tremor.

2013

Pathological tremor is the most prevalent movement disorder. In spite of the existence of various treatments for it, tremor poses a functional problem to a large proportion of patients. This paper presents the design and implementation of a novel neuroprosthesis for tremor management. The paper starts by reviewing a series of design criteria that were established after analyzing users needs and the expected functionality of the system. Then, it summarizes the design of the neuroprosthesis, which was built to meet the criteria defined previously. Experimental results with a representative group of 12 patients show that the neuroprosthesis provided significant (p <; 0.001) and systematic trem…

AdultMaleEngineeringmedicine.medical_specialtyNeuroprostheticsNeural ProsthesesMovementProsthesis DesignUpper ExtremityYoung AdultPhysical medicine and rehabilitationTremormedicineAnimalsHumansPatient treatmentAgedFunctional evaluationbusiness.industryReproducibility of ResultsRoboticsMiddle AgedLarge cohortmedicine.anatomical_structureMedical roboticsPhysical therapyUpper limbFemalebusinessMuscle ContractionAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
researchProduct

Timing of Triggering in Relation to the Cardiac Cycle in Nonelite Rifle Shooters

2003

This study investigated the timing of the trigger pull in relation to the cardiac cycle during air rifle shooting. Electrocardiogram) was recorded from 20 male nonelite rifle shooters in two separate testing sessions. The testing was conducted at an indoor shooting range using an optoelectronic shooting system. Each participant fired a shot in the standing position at a distance of 10 m from the target. The results showed that compared to random triggering, the shooters fired more often during the phase of 10-50% of the R wave-to-R wave (R-R) interval and less often during the phase of 50-90%. With regard to performance accuracy, the participants exhibited average or above average performan…

AdultMaleFirearmsmedicine.medical_specialtyCardiac cyclePhysical Therapy Sports Therapy and RehabilitationShooting rangeGeneral MedicineMyocardial ContractionElectrocardiographyPhysical FitnessNephrologyShot (pellet)Internal medicineHeart ratemedicineCardiologyHumansOrthopedics and Sports MedicineRifleSportsMathematicsResearch Quarterly for Exercise and Sport
researchProduct

Changes of electrically elicited reflexes in hand and forearm muscles in man.

1987

Cutaneo-muscular reflexes with short and long latency excitatory phases following digital nerve stimulation were observed in the first dorsal interosseus muscle of the hand in healthy subjects. The short latency reflex was obtained also with the H-reflex method in the flexor carpi radialis muscle, stimulating the median nerve, with a mean latency (+/- SE) of 15.4 +/- 0.5 ms. The height of the subject correlated with the H-reflex latency. The amplitudes of maximal M-response and maximal H-reflex were higher in athletes than in normals. During weak voluntary contraction of the muscle studied the 50% H-reflex amplitude increased and during passive stretching of wrist flexors the resting amplit…

AdultMaleFlexor carpi radialis musclePhysical Therapy Sports Therapy and RehabilitationPassive stretchingElectromyographyH-ReflexForearmmedicineHumansLatency (engineering)medicine.diagnostic_testbusiness.industryElectromyographyReflex MonosynapticMusclesRehabilitationAnatomyHandMedian nerveElectric Stimulationbody regionsForearmmedicine.anatomical_structurePhysical FitnessReflexUpper limbFemalebusinessMuscle ContractionAmerican journal of physical medicine
researchProduct

Time‐of‐Day Effect on the Torque and Neuromuscular Properties of Dominant and Non‐Dominant Quadriceps Femoris

2005

The study was conducted first, to determine the possibility of a dichotomy between circadian rhythm of maximal torque production of the knee extensors of the dominant and non-dominant legs, and second, to determine whether the possible dichotomy could be linked to a change in the downward drive of the central nervous system and/or to phenomena prevailing at the muscular level. The dominant leg was defined as the one with which subjects spontaneously kick a football. Tests were performed at 06:00, 10:00, 14:00, 18:00, and 22:00 h. To distinguish the neural and muscular mechanisms that influence muscle strength, the electromyographic and mechanical muscle responses associated with electricall…

AdultMaleFootednessmedicine.medical_specialtyTime FactorsPhysiologyElectromyographyThighBody TemperatureTime of dayPhysiology (medical)Internal medicinemedicineHumansTorqueCircadian rhythmMuscle Skeletalmedicine.diagnostic_testElectromyographybusiness.industryAnatomyElectric StimulationCircadian RhythmPeripheralmedicine.anatomical_structureThighTorqueCardiologymedicine.symptombusinessMuscle ContractionMuscle contractionChronobiology International
researchProduct

Four unrelated patients with lubs X-linked mental retardation syndrome and different Xq28 duplications

2010

The Lubs X-linked mental retardation syndrome (MRXSL) is caused by small interstitial duplications at distal Xq28 including the MECP2 gene. Here we report on four novel male patients with MRXSL and different Xq28 duplications delineated by microarray-based chromosome analysis. All mothers were healthy carriers of the duplications. Consistent with an earlier report [Bauters et al. (2008); Genome Res 18: 847-858], the distal breakpoints of all four Xq28 duplications were located in regions containing low-copy repeats (LCRs; J, K, and L groups), which may facilitate chromosome breakage and reunion events. The proximal breakpoint regions did not contain known LCRs. Interestingly, we identified …

AdultMaleHeterozygoteBotulinum ToxinsAdolescentMethyl-CpG-Binding Protein 2MECP2 duplication syndromeMothersBiologyMECP2Gene duplicationGeneticsmedicineHumansChildGenetics (clinical)X chromosomeMuscle contractureChromosome AberrationsGeneticsChromosomes Human XBreakpointInfantmedicine.diseasePedigreeXq28Child PreschoolMental Retardation X-LinkedFemaleChromosome breakageAmerican Journal of Medical Genetics Part A
researchProduct

Positive inotropic response to 5-HT in human atrial but not in ventricular heart muscle

1992

The effects of 5-hydroxytryptamine (5-HT) on force of contraction (FC), action potential (AP) and calcium current (ICa) were studied in human right atrial and left ventricular heart muscle. 5-HT exerted a concentration-dependent increase in FC in multicellular atrial preparations; the EC50 was approximately 3 x 10(-7) mol/l. Maximal increases in FC (252 +/- 58% of control values; mean +/- SEM, n = 6) were obtained at 5-HT 10(-5) mol/l. At this concentration, ICa was increased four- to sevenfold in enzymatically isolated atrial myocytes. In contrast, ventricular preparations did not respond to 5-HT; FC, AP and ICa remained unaffected. In the same preparations, FC was increased by isoprenalin…

AdultMaleInotropeSerotoninmedicine.medical_specialtyHeart VentriclesIn Vitro TechniquesAdenylyl cyclasechemistry.chemical_compoundInternal medicineIsoprenalineHumansMedicineHeart AtriaAtrium (heart)ReceptorAgedPharmacologybusiness.industryMyocardiumIsoproterenolGeneral MedicineMiddle AgedPapillary Musclesmedicine.diseaseMyocardial Contractionmedicine.anatomical_structureEndocrinologychemistryVentricleHeart failureCirculatory systemcardiovascular systemFemaleCalcium Channelsbusinessmedicine.drugNaunyn-Schmiedeberg's Archives of Pharmacology
researchProduct

Modulation of intracortical inhibition induced by low- and high-frequency repetitive transcranial magnetic stimulation.

2001

We studied the changes of duration of subsequent silent periods (SPs) during repetitive magnetic stimulation (rTMS) trains of ten stimuli delivered at low (1 Hz) and high (7 Hz) frequencies. The effects at different intensities of stimulation (motor threshold, MT, 115% and 130% above the MT) were also evaluated. rTMS was performed in eight healthy subjects with a figure-of-eight coil placed over the hand motor area. The SP was recorded from abductor pollicis brevis (APB) muscle during a voluntary contraction of 30% of maximum effort. rTMS at 1-Hz frequency progressively decreased the duration of SP, whereas an alternating pattern of smaller and larger values was observed during trains at 7-…

AdultMaleInterneuronmedicine.medical_treatmentMovementStimulationStimulus (physiology)H-ReflexNuclear magnetic resonanceNeural PathwaysmedicineReaction TimeHumansMuscle SkeletalMotor NeuronsChemistryElectromyographyGeneral NeuroscienceMotor CortexMotor controlNeural InhibitionEvoked Potentials MotorTranscranial Magnetic StimulationElectric StimulationTranscranial magnetic stimulationElectrophysiologymedicine.anatomical_structureSilent periodFemaleNeuroscienceMotor cortexMuscle ContractionExperimental brain research
researchProduct

Human isometric force production and electromyogram activity of knee extensor muscles in water and on dry land.

1999

This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both th…

AdultMaleKnee JointPhysiologyVastus medialisIntraclass correlationIsometric exerciseElectromyographyBicepsIsometric ContractionMedicineHumansMuscle SkeletalHydrotherapyReproducibilityKnee extensorsmedicine.diagnostic_testbusiness.industryElectromyographyPublic Health Environmental and Occupational HealthReproducibility of ResultsWaterAnatomyElectrophysiologyFemalebusinessBiomedical engineeringEuropean journal of applied physiology and occupational physiology
researchProduct

Electromechanical behaviour of human muscles in vertical jumps

1982

The relationships of muscle structure to the potentiation of myoelectrical activity and to the use of prestretching in five lower limb muscles were studied in different vertical jumping conditions. The subjects for the study were six male students, divided according to the muscle fiber distribution in m. vastus lateralis into “fast” and “slow” groups. The subjects performed vertical jumps (1) from a static squatting position (SJ), (2) with a preliminary counter movement (CMJ) and (3) after dropping (DJ) from five different heights. Myoelectrical (EMG) activity was recorded from mm. gluteus maximus, vastus lateralis, vastus medialis, rectus femoris and gastrocnemius in each jumping condition…

AdultMaleKnee JointPhysiologyVastus medialisMovementElectromyographyConcentricSports Medicinemedicine.disease_causeJumpingPhysiology (medical)medicineHumansEccentricOrthopedics and Sports MedicineMuscle fibreLegmedicine.diagnostic_testElectromyographyChemistryMusclesTrack and FieldPublic Health Environmental and Occupational HealthGeneral MedicineAnatomymusculoskeletal systemVertical jumpingbody regionsSquatting positionMuscle ContractionEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Effects of a 21 days space flight on the mechanical performance and the EMG power spectrum of the leg muscles

2002

AdultMaleLegMaterials scienceElectromyographyWeightlessnessBiomedical EngineeringSpectral densitySignal Processing Computer-AssistedSpace Flightmaximal power; space fligth; microgravitySpaceflightmicrogravitylaw.inventionLeg musclespace fligthlawReference Valuesmaximal powerIsometric ContractionExercise TestHumansMuscle SkeletalSimulation
researchProduct