Search results for "Contrast media"
showing 10 items of 323 documents
LESIONI FOCALI RENALI (LFR): RUOLO DELLA CEUS NELLA CARATTERIZZAZIONE DI LESIONI BENIGNE E MALIGNE
2018
MultiSlice human organ extraction based on GVF
2008
Segmentation techniques based on active contours algorithm are widely used in medical imaging. Unfortunately, they require a lot of parameters to be used and this can rep- resent an issue for those physicians with not much informatics skills. This paper proposes a software tool which allows to segment multiple slice can differ organ extraction setting a small number of parameters. Moreover, the tool offers the functionality to perform a multiple segmentation the same time, so that an entire volume composed by hundreds slices can be segmented.
Mixed micelles composed of Peptides and Gadolinium complexes as tumor-specific contrast agents in MRI: a SANS study
2004
A detailed structural investigation on mixed micelle aggregates as target-specific contrast agents for magnetic resonance imaging technique has been carried out by way of small angle neutron scattering measurements. These mixed micelles are formed by two new amphiphilic molecules formed by a bioactive peptide and a claw moiety. The first molecule, C18H37CONH(AdOO)(x)-G-CCK8 (C18LxCCK8, x = 2, 5), contains an 18-carbon-atom alkylic chain bound to the C-terminal of the cholecystokinin octapeptide amide (CCK 26-33 or CCK8) and is able to bind to the overexpressed CCK receptor of some tumor cells. The second molecule, C(18)H(37)CONHLys(DTPAGlu)CONH25- (C18DTPAGlu) or its gadolinium complex [C(1…
Diffusion of ionic and non-ionic contrast agents in articular cartilage with increased cross-linking--contribution of steric and electrostatic effect…
2013
Abstract Objective To investigate the effect of threose-induced collagen cross-linking on diffusion of ionic and non-ionic contrast agents in articular cartilage. Design Osteochondral plugs (O=6mm) were prepared from bovine patellae and divided into two groups according to the contrast agent to be used in contrast enhanced computed tomography (CECT) imaging: (I) anionic ioxaglate and (II) non-ionic iodixanol. The groups I and II contained 7 and 6 sample pairs, respectively. One of the paired samples served as a reference while the other was treated with threose to induce collagen cross-linking. The equilibrium partitioning of the contrast agents was imaged after 24h of immersion. Fixed char…
The role of MR imaging in the assessment of renal allograft vasculature.
2018
Renal allograft dysfunction after transplantation is a relatively common occurrence with various potential etiologies. Vascular etiologies are of particular importance as early surgical or minimally invasive intervention can, in some cases, salvage the graft. Diagnosis of vascular pathology resulting in allograft dysfunction requires a thorough workup, of which imaging is a key component. Generally, ultrasound is the first-line imaging modality. More recently, MRI has been shown to be an effective and safe modality for diagnosis of vascular pathology after renal transplantation, particularly for diagnosis of transplant renal artery stenosis. This review will summarize imaging modalities tha…
MRI of tarantulas: morphological and perfusion imaging.
2005
This paper describes a study performed to evaluate the feasibility of using a 1.5-T whole-body magnetic resonance imaging (MRI) equipment, in combination with pharmacokinetic modeling, to obtain in vivo information about the morphology and perfusion of tarantulas (Eurypelma californicum). MRI was performed on three tarantulas using spin-echo sequences for morphological imaging and a rapid spoiled gradient-echo sequence for dynamic imaging during and after contrast medium (CM; Gd-DTPA) injection. Signal enhancement in dynamic measurements was evaluated with a pharmacokinetic two-compartment model. Spin-echo images showed morphological structures well. Dynamic images were of sufficient qualit…
Qualitative and quantitative evaluation of solitary thyroid nodules with contrast-enhanced ultrasound: initial results
2005
To assess the feasibility of contrast-enhanced ultrasound (CEUS) of the thyroid gland and to evaluate the potential of this method for characterising solitary thyroid nodules.18 patients affected by solitary thyroid nodules (size range: 0.6 to 3.6 cm; mean: 1.8 cm) confirmed by surgery (nine papillary carcinomas, four follicular carcinomas, three hyperplasias, one follicular adenoma and one Plummer’s adenoma) underwent pulse inversion US at low M.I. (0.06 to 0.08) after i.v. injection of a 2.4-mL bolus of SonoVue. Baseline echogenicity and the dynamic enhancement pattern of each nodule, in comparison with adjacent thyroid parenchyma, were assessed. Signal intensity values on grey-scale imag…
Stability of irinotecan-loaded drug eluting beads (DC BeadTM) used for transarterial chemoembolization
2009
Purpose. The aim of this study was to determine the loading efficiency, physicochemical stability, and release of irinotecan-loaded DC BeadsTM (bead size 100—300 μm, 300—500 μm) before and after mixing with nonionic contrast medium (Accupaque® 300, Imeron® 300, Ultravist ® 300) during a prolonged period of time (28 days) when stored at room temperature or refrigerated. Methods. DC Beads TM were loaded with 50 mg irinotecan (Campto®) per milliliter beads in a 2 h loading period. Drug loading efficiency and stability were determined by measuring the irinotecan concentration in the excess solution. A free-flowing in vitro elution method for a period of 2 h and phosphate buffered solution (PBS…
Introduction to coronary imaging with 64-slice computed tomography
2005
The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.
Analysis of fluorescent MRI contrast agent behavior in the liver and thoracic aorta of mice.
2004
To characterize the behavior of magnetofluorescent products injected in mice intravenously.The magnetic resonance imaging (MRI) products were labelled with fluorescent molecules to examine the biodistribution process in vivo and observe them at the cellular level by means of confocal microscopy. Three-dimensional (3D) sequences of images were obtained by spectral analysis of sample preparations in a multiphoton confocal microscope and analyzed by the factor analysis of medical image sequence algorithm, which provides factor curves. Factor images are the result of image-processing methods that utilize information from emission spectra. Preparations are also screened in the counting mode to p…