Helical computed tomographyangiography: Technical considerations and clinical applications
1997
Abstract A combination of volume acquisition techniques (helical CT), dedicated protocolsfor bolus injections of contrast medium, and postprocessing modalities have paved the way for computed tomography (CT) angiography. To obtain optimum results the collimation must be adapted to the vascular territory of interest, and the reconstruction of overlapping source images from the volume data set is advantageous for further postprocessing. Strong intravascular opacification is indispensable for the evaluation of vascular abnormalities and pathology and is also helpful for image postprocessing, where different modalities can be applied: multiplanar reconstruction, maximum intensity projection, se…
Gadolinium-DTPA (Magnevist®) als Kontrastmittel für die arterielle DSA
1994
16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2-0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even…
Systematische Analyse der Geometrie eines definierten Kontrastmittelbolus - Implikationen für die kontrastmittelverstärkte 3D-MR-Angiographie thoraka…
2005
Purpose: Little is known about the dispersion of a defined contrast bolus during its passage through the heart and pulmonary vasculature. The purpose of this study was to analyze factors influencing a defined contrast bolus for ce-MRA of thoracic vessels. Materials and Methods: For analysis of bolus geometry, an ECG-gated saturation-recovery Turbo-Flash sequence with a TI of 20 msec was used. It was acquired axially at the level of the pulmonary trunc, so that with one data acquisition a curve analysis was possible in the ascending and descending aorta, and in the pulmonary trunc. Twenty-nine patients received 3 ml of Gd-DTPA diluted with saline to a total of 20 ml. Contrast injection was d…
Eine Kombination niedrig und hochauflösender dynamischer T1-gewichteter Sequenzen zur besseren Beurteilung der Morphologie Kontrastmittel aufnehmende…
2002
Purpose: Presentation of a new protocol for simultaneous acquisition of both low and high resolution T 1 -weighted images of breast lesions for dynamic contrast-enhanced MR mammography. Demonstration of possible diagnostic improvement with representative measurements in patients with suspected breast cancer by adding morphologic parameters from high resolution sequences to the analysis of the signal-time curve. Materials and Methods: Dynamic MR imaging was performed with a 1.5 T system (Magnetom SONATA, Siemens Medical Systems, Germany) and the manufacturer's double-breast coil. Coronal T 1 -weighted 3D FLASH sequences (spatial resolution 1.25 ×1.25 mm 2 ; slice thickness 1.7 mm) were acqui…
Zur Frage der Darmkontrastierung in der abdominellen Computertomographie
1992
In 56 patients undergoing abdominal CT the gastrointestinal tract was defined by negative contrast instead of the conventional positive contrast from an iodine containing contrast medium. The contrast material was a 2 1/2% mannitol solution and was used for filling the rectum. Filling of the gastrointestinal tract was of similar quality to that obtained with positive contrast media. The number of artifacts due to high contrast boundaries was slightly greater with the negative contrast than it would have been with positive contrast. Differentiation of the gastrointestinal tract from other abdominal organs was equally good for both methods. The negative contrast method was poor in diagnosing …
MR imaging of perianal Crohn’s disease: Is contrast medium necessary?
2010
Purpose Methods and Materials Results Conclusion References Personal Information
Kontrastmittel-Kurzinfusion oder -Bolusinjektion bei der i.v. Urographie
1993
The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the …
Contrast-enhanced MRI of the lung
2000
The lung has long been neglected by MR imaging. This is due to unique intrinsic difficulties: (1) signal loss due to cardiac pulsation and respiration; (2) susceptibility artifacts caused by multiple air-tissue interfaces; (3) low proton density. There are many MR strategies to overcome these problems. They consist of breath-hold imaging, respiratory and cardiac gating procedures, use of short repetition and echo times, increase of the relaxivity of existing spins by administration of intravenous contrast agents, and enrichment of spin density by hyperpolarized noble gases or oxygen. Improvements in scanner performance and frequent use of contrast media have increased the interest in MR ima…
Ultrastructural biologic effects of sonography with pulse inversion and microbubble contrast in rabbit liver
2005
Purpose This prospective study was conducted to evaluate the biologic effects of microbubble destruction with pulse-inversion harmonic imaging on rabbit liver parenchyma. Methods The livers of 6 albino rabbits were examined sonographically by a single investigator. Three rabbits underwent contrast-enhanced sonography, with scanning starting 5 seconds after injection by using pulse-inversion harmonic imaging with a mechanical index of 1.2. Four time-triggered images were recorded at a rate of 1 frame every 2 seconds. For comparison, 3 control rabbits had pulse-inversion harmonic imaging with a mechanical index of 1.2 only, without contrast medium. Immediately after sonography, the animals we…
Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair
2019
Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…