Search results for "Cornea."

showing 10 items of 403 documents

Clinical guidelines for diagnosing and managing ocular manifestations in children with mucopolysaccharidosis.

2011

The mucopolysaccharidoses (MPS) are a group of rare lysosomal storage disorders characterized by the accumulation of glycosaminoglycans in several tissues and organs. This accumulation results in an array of clinical manifestations and premature death in severe cases. Ocular problems are very common in children with MPS and may involve the cornea, sclera, trabecular meshwork, retina, optic nerve and also the posterior visual pathways. The aims of this study are to give an overview of ocular problems in MPS and to provide clinical guidelines for paediatric ophthalmologists for early diagnosis and management of ocular manifestations in children with MPS. Diagnostic problems may arise in child…

Pediatricsmedicine.medical_specialtygenetic structuresEye DiseasesMucopolysaccharidosisLysosomal storage disordersDiagnostic Techniques Ophthalmological03 medical and health sciences0302 clinical medicineOphthalmologyCorneaPrescription glassesMedicineHumansChildbusiness.industryInfant Newbornnutritional and metabolic diseasesInfantGeneral MedicineMucopolysaccharidosesmedicine.diseaseeye diseases3. Good healthScleraOphthalmologyPremature deathmedicine.anatomical_structureEyeglassesChild PreschoolPractice Guidelines as Topic030221 ophthalmology & optometryOptic nerveQuality of Lifesense organsTrabecular meshworkbusiness030217 neurology & neurosurgeryActa ophthalmologica
researchProduct

Propolis-Based Nanofiber Patches to Repair Corneal Microbial Keratitis

2021

In this research, polyvinyl-alcohol (PVA)/gelatin (GEL)/propolis (Ps) biocompatible nanofiber patches were fabricated via electrospinning technique. The controlled release of Propolis, surface wettability behaviors, antimicrobial activities against the S. aureus and P. aeruginosa, and biocompatibility properties with the mesenchymal stem cells (MSCs) were investigated in detail. By adding 0.5, 1, and 3 wt.% GEL into the 13 wt.% PVA, the morphological and mechanical results suggested that 13 wt.% PVA/0.5 wt.% GEL patch can be an ideal matrix for 3 and 5 wt.% propolis addition. Morphological results revealed that the diameters of the electrospun nanofiber patches were increased with GEL (from…

Pharmaceutical ScienceBiocompatible Materials02 engineering and technologyGelatinAnalytical ChemistryContact angleQD241-4410302 clinical medicineAnti-Infective AgentsSpectroscopy Fourier Transform InfraredDrug DiscoveryMesenchymal stem cell proliferationDrug CarriersChemistrySSCAFFOLDHYDROGELP<i>S. aureus</i>021001 nanoscience & nanotechnologyControlled releaseaeruginosaElectrospinningpropolisChemistry (miscellaneous)microbial keratitisPseudomonas aeruginosaBLINDNESSMolecular MedicineELECTROSPUN0210 nano-technologyStaphylococcus aureusfood.ingredient<i>P. aeruginosa</i>BiocompatibilitySurface PropertiesFABRICATIONMicrobial Sensitivity TestsCHEMICAL-COMPOSITIONaureusArticle03 medical and health sciencesfoodnanofibersPhysical and Theoretical Chemistrycorneal patchelectrospinningKeratitisCOMPOSITEGELATINOrganic ChemistryPropolisS. aureusDrug LiberationP. aeruginosaPolyvinyl AlcoholNanofiber030221 ophthalmology & optometryPROPERTYMEMBRANENuclear chemistry
researchProduct

Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt.

2011

PURPOSE: To evaluate the changes in optical quality when toric intraocular lenses (IOL) are rotated or tilted and to demonstrate that IOL rotation produces an increasing effect of aberrations. METHODS: Modulation transfer function (MTF) and average modulation were used to analyze the image quality of a toric IOL. The axis of the toric IOL was rotated 5°, 10°, 15°, 20°, 25°, and 30° in successive MTF measurements. The tilt values were 0° to 5°, in increments of 1°, plus a tilt of 15°. Pupil diameters of 3 and 5 mm were used. RESULTS: The MTF decay due to aberrations was more sensitive to rotation than tilt. The main decrement in the average modulation, of approximately 50% in both pupils, o…

PhysicsLenses IntraocularOptics and PhotonicsCorneal Wavefront AberrationRotationbusiness.industrymedicine.medical_treatmentIntraocular lensModels TheoreticalRotationArtificial Lens Implant MigrationOptical qualityExponential functionOphthalmologyTilt (optics)OpticsIntraocular lensesModulationOptical transfer functionmedicineHumansSurgerybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Repeatability of whole-cornea measurements using a new swept-source optical coherence tomographer

2020

Purpose: The aim of this study was to evaluate the repeatability of several corneal parameters provided by a high-resolution swept-source optical coherence tomographer (SS-OCT). Methods: One eye from each of 74 patients was measured five times consequently using the ANTERION SS-OCT. The following corneal parameters were analyzed: average, steep and flat keratometry (K), astigmatism for anterior, posterior and total at 3-mm, average K and astigmatism at 6-mm, anterior and posterior eccentricity, higher-order aberrations (HOA) and spherical aberration ([Formula: see text]), and anterior and posterior best-fit sphere at 8-mm. The intrasubject standard deviation (Sw), coefficient of variation (…

Physicsmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyReproducibility of ResultsGeneral MedicineRepeatabilityCoherence (statistics)030204 cardiovascular system & hematologyRefraction OcularCorneal topographyCornea03 medical and health sciencesOphthalmology0302 clinical medicineOpticsmedicine.anatomical_structureOptical coherence tomographyCornea030221 ophthalmology & optometrymedicineHumansbusinessTomography Optical CoherenceEuropean Journal of Ophthalmology
researchProduct

Orbscan Pachymetry: Differences between observers when carrying out measurements of the corneal thickness

2005

espanolObjetivo: Estudiar el espesor corneal y la variabilidad entre observadores de las mediciones del espesor corneal empleando paquimetria Orbscan. Metodos: Analizamos el espesor corneal central y paracentral de 30 sujetos (n=30) cuya edad oscilaba entre 19 y 38 anos (media 27,27 D.E. 5,25) con el Sistema Topografico Orbscan II (Orbscan, Inc., Salt Lake City, UT, USA). La media de cinco mediciones consecutivas del espesor corneal fue obtenida por dos diferentes observadores. Los resultados obtenidos por los dos observadores se compararon. Resultados: No se encontraron diferencias significativas entre los valores medios del espesor corneal de los observadores en la cornea central (p=0,749…

Physicsmedicine.medical_specialtycorneal thicknessSalt lakeCórneaCorneaOphthalmologymedicine.anatomical_structureOrbscanCorneaOphthalmologymedicinepachymetryOrbscan iiCartographypaquimetríaespesor corneal
researchProduct

Midbrain vs. pontine medial longitudinal fasciculus lesions: The utilization of masseter and blink reflexes

1991

Masseter (MR) and blink reflexes (BL) were investigated in 51 patients with internuclear ophthalmoplegia (INO) due to multiple sclerosis (28) and lacunar infarction (23). The MR was abnormal in 20 of 23 cases with bilateral INO and in 21 of 28 with unilateral INO. The R1 component of the BL (BL-R1) was abnormal in 7 of 23 patients with bilateral INO and 10 of 28 with unilateral INO. Combined MR and BL-R1 changes occurred in 8 of 28 cases with unilateral INO and 7 of 23 with bilateral INO. The findings provide evidence for a rostral/caudal localization of lesions within the medial longitudinal fasciculus causing INO on the basis of MR and BL-R1 abnormalities. An abnormality limited to MR sug…

Physiologybusiness.industryCerebral infarctionInternuclear ophthalmoplegiaAnatomymedicine.diseaseMedial longitudinal fasciculusPonsMasseter muscleMidbrainCellular and Molecular NeurosciencePhysiology (medical)MedicineNeurology (clinical)Corneal reflexbusinessJaw jerk reflexMuscle &amp; Nerve
researchProduct

In Vitro Generation of Pancreatic Endocrine Cells from Human Adult Fibroblast-Like Limbal Stem Cells

2012

Stem cells might provide unlimited supply of transplantable cells for β-cell replacement therapy in diabetes. The human limbus is a highly specialized region hosting a well-recognized population of epithelial stem cells, which sustain the continuous renewal of the cornea, and the recently identified stromal fibroblast-like stem cells (f-LSCs), with apparent broader plasticity. However, the lack of specific molecular markers for the identification of the multipotent limbal subpopulation has so far limited the investigation of their differentiation potential. In this study we show that the human limbus contains uncommitted cells that could be potentially harnessed for the treatment of diabete…

Pluripotent Stem CellsStromal cellCellular differentiationPopulationBiomedical Engineeringlcsh:MedicineEnteroendocrine cellLimbus CorneaeBiologyLimbus; β-CellsSettore MED/13 - EndocrinologiaLimbuInsulin-Secreting CellsInsulin SecretionDiabetes MellitusHumansInsulineducationInduced pluripotent stem cellCells CulturedProinsulinTransplantationeducation.field_of_studyDiabeteslcsh:RCell DifferentiationCell Biologyβ-CellsCell biologyAdult Stem CellsStem cellFibroblast-like stem cellsBiomarkersAdult stem cellCell Transplantation
researchProduct

Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

2013

Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…

Point spread functionAdultMalePhakic Intraocular LensesVisual acuityCorneal Wavefront AberrationAdolescentVisual AcuityAstigmatismPupilContrast SensitivityYoung AdultBioptics (surgery)Lens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansAdaptive opticsSimulationMathematicsAberrometryAstigmatismmedicine.diseaseSensory SystemsOphthalmologyFemaleSpatial frequencymedicine.symptomOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Diffractive corneal inlay for presbyopia

2017

[EN] A conceptually new type of corneal inlays for a customized treatment of presbyopia is presented. The diffractive inlay consists on a small aperture disc having an array of micro-holes distributed inside the open zones of a Fresnel zone plate. In this way, the central hole of the disc lets pass the zero order diffraction and produces an extension of the depth of far focus of the eye, while the diffracted light through the holes in the periphery produce the near focus. Additionally, the micro-holes in the inlay surface fulfill the essential requirement of allowing the flow of nutrients through it to the cells of the corneal stroma. Theoretical and optical-bench experimental results for t…

Point spread functionDiffractionMaterials sciencegenetic structuresCorneal Stromamedicine.medical_treatmentDiffractive lensesVisual AcuityGeneral Physics and AstronomyZone plateProsthesis Design01 natural sciencesGeneral Biochemistry Genetics and Molecular Biologylaw.inventionCornea010309 optics03 medical and health sciences0302 clinical medicineOpticslawcorneaRefractive surgeryCornea0103 physical sciencesmedicineHumansGeneral Materials ScienceRefractive surgerydiffractive lensesintegumentary systemInlaybusiness.industryGeneral EngineeringProstheses and ImplantsPresbyopiaGeneral ChemistryPresbyopiamedicine.diseaseCorneal inlayeye diseasesmedicine.anatomical_structureFISICA APLICADArefractive surgery030221 ophthalmology & optometrysense organsbusinessJournal of Biophotonics
researchProduct

Imaging Performance of a Diffractive Corneal Inlay for Presbyopia in a Model Eye

2019

[EN] In this work we evaluated the imaging properties of the Diffractive Corneal Inlay (DCI), a novel type of corneal implant working by diffraction that we proposed for the treatment of presbyopia. ZEMAX OpticStudio software was employed for the numerical assessment, with simulations performed in a human-based eye model. In the ray tracing analysis, we used the Modulation Transfer Function (MTF), the Area under the MTF (AMTF), and the Point Spread Function (PSF). The theoretical performance of the DCI under different situations was evaluated in comparison with a commercially available pinhole based corneal inlay. Finally, real images were obtained experimentally in vitro in a model eye wit…

Point spread functionGeneral Computer ScienceComputer scienceDiffractive lenses01 natural sciencesoptical design010309 optics03 medical and health sciencesOpticsOptical transfer function0103 physical sciencesmedicine03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadesGeneral Materials ScienceZemax030304 developmental biologydiffractive lenses0303 health sciencesbusiness.industryGeneral EngineeringPresbyopiaPresbyopiamedicine.diseaseReal imageCorneal inlayPresbyopia Optical designFISICA APLICADARay tracing (graphics)lcsh:Electrical engineering. Electronics. Nuclear engineeringbusinessCorneal inlayslcsh:TK1-9971IEEE Access
researchProduct