Orbscan Pachymetry: Differences between observers when carrying out measurements of the corneal thickness

L AlonsoRahhalJuan A. Sanchis-gimenoAntonio Lleó-pérez

subject

Physicsmedicine.medical_specialtycorneal thicknessSalt lakeCórneaCorneaOphthalmologymedicine.anatomical_structureOrbscanCorneaOphthalmologymedicinepachymetryOrbscan iiCartographypaquimetríaespesor corneal

description

espanolObjetivo: Estudiar el espesor corneal y la variabilidad entre observadores de las mediciones del espesor corneal empleando paquimetria Orbscan. Metodos: Analizamos el espesor corneal central y paracentral de 30 sujetos (n=30) cuya edad oscilaba entre 19 y 38 anos (media 27,27 D.E. 5,25) con el Sistema Topografico Orbscan II (Orbscan, Inc., Salt Lake City, UT, USA). La media de cinco mediciones consecutivas del espesor corneal fue obtenida por dos diferentes observadores. Los resultados obtenidos por los dos observadores se compararon. Resultados: No se encontraron diferencias significativas entre los valores medios del espesor corneal de los observadores en la cornea central (p=0,749), nasal (p= 0,931), superonasal (p=0,847), inferonasal (p=0,930), temporal (p=0,918), superotemporal (p=0,912) e inferotemporal (p=0,760). El maximo espesor corneal se encontro frecuentemente en la cornea superonasal (14 de 30 ojos para el observador 1, y 16 de 30 ojos para el observador 2). La diferencia entre el espesor central y el maximo paracentral fue de 117 D.E. 22 y 117 D.E. 23 micras para el observador 1 y 2 respectivamente (p=0,974). La diferencia entre el espesor central y el minimo paracentral fue 40 D.E. 20 y 39 D.E. 19 micras para el observador 1 y 2 respectivamente (p=0,846). La diferencia entre el minimo y el maximo espesor paracentral fue de 76 D.E. 24 y 77 D.E. 23 micras para el observador 1 y 2 respectivamente (p=0,895) Conclusiones: La paquimetria Orbscan permite realizar estudios del espesor corneal por diferentes observadores sin haber diferencias significativas entre ellos. EnglishPurpose: To study the corneal thickness and the inter-observer variability of corneal thickness measurements by means of Orbscan pachymetry. Methods: We analysed the central and para-central corneal thickness of 30 subjects, whose age ranged from 19 to 38 years (mean 27.27, S.D. 5.25), with the Orbscan Topography System II (Orbscan, Inc., Salt Lake City, UT, USA). The mean of five consecutive measurements of the corneal thickness were obtained by two different observers and the results obtained were compared. Results: No significant differences in mean corneal thickness between observers were found at central (p=0.749), nasal (p=0.931), supero-nasal (p=0.847), infero-nasal (p=0.930), temporal (p=0.918), supero-temporal (p=0.912) and infero-temporal (p=0.760) regions of the cornea. The maximum mean corneal thickness was found most commonly at the supero-nasal cornea (14 of 30 eyes for observer 1, and 16 of 30 eyes for observer 2). The difference between the central thickness and the maximum para-central thickness was 117 (S.D. 22) and 117 (S.D. 23) microns for observers 1 and 2 respectively (p=0.974). The difference between the central thickness and the minimum para-central thickness was 40 (S.D. 20) and 39 (S.D. 19) microns for observers 1 and 2 respectively (p=0.846). The difference between the minimum and the maximum para-central thickness was 76 (S.D. 24) and 77 (S.D. 23) microns for observers 1 and 2 respectively (p=0.895). Conclusions: Orbscan pachymetry allows central and para-central corneal studies to be carried out by different observers without any significant differences being found between them.

http://scielo.isciii.es/scielo.php?script=sci_arttext&pid=S0365-66912005000500005&lng=en&tlng=en