Search results for "Cornea"

showing 10 items of 404 documents

Interchangeability among five devices that measure anterior eye distances.

2014

The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…

AdultMaleBiometrybusiness.industryAnterior ChamberMeasure (physics)Corneal TopographyReproducibility of ResultsEquipment DesignRefraction OcularRefractive ErrorsInterchangeabilityCorneaOphthalmologyYoung AdultOpticsOptometryMedicineHumansFemaleProspective StudiesbusinessOptometryFollow-Up StudiesClinicalexperimental optometry
researchProduct

Association of Low Birth Weight With Altered Corneal Geometry and Axial Length in Adulthood in the German Gutenberg Health Study

2019

IMPORTANCE: Low birth weight is associated with altered ocular organ development in childhood, including the morphology of the eye. However, no population-based data exist about this association in adulthood. OBJECTIVE: To evaluate whether low birth weight has a long-term association with anterior segment anatomy and axial length in adulthood. DESIGN, SETTING, AND PARTICIPANTS: The Gutenberg Health Study is a population-based, observational cohort study in Germany. All participants underwent ocular biometry. Among the participants with follow-up and self-reported birth weight available, associations were assessed between low birth weight and anterior segment anatomy and axial length using m…

AdultMaleBirth weightPopulationGeometry01 natural sciencesCohort StudiesCornea03 medical and health sciences0302 clinical medicineCorneaGermanymedicineHumansIn patient0101 mathematicseducationOriginal InvestigationAgedAged 80 and overeducation.field_of_studybusiness.industry010102 general mathematicsInfant NewbornRetinopathy of prematurityAxial lengthInfant Low Birth WeightMiddle Agedmedicine.diseaseOphthalmologyLow birth weightAxial Length Eyemedicine.anatomical_structure030221 ophthalmology & optometryFemalemedicine.symptombusinessCohort study
researchProduct

Topodiagnostic value of blink reflex R1 changes: a digital postprocessing MRI correlation study.

2001

The aim of the study was to investigate the relation of the blink reflex R1 arc to known anatomical brainstem structures. Acute vascular brainstem lesions as identified by magnetic resonance imaging (MRI) of patients with isolated R1 pathology were superimposed into a stereotactic anatomical atlas using a new method of digital postprocessing. Isolated acute brainstem lesions were documented by diffusion-weighted MRI in 12 of 24 patients with unilateral R1 pathology. The lesions were located in the ipsilateral mid- to lower pons. In three patients only, the lesion had partial contact with the principal sensory nucleus of the trigeminal nerve (PSN) on at least one level. In two patients, the …

AdultMaleBrain Stem InfarctionsPhysiologyCellular and Molecular NeurosciencePhysiology (medical)medicineImage Processing Computer-AssistedHumansCorneal reflexAgedTrigeminal nerveAged 80 and overmedicine.diagnostic_testBlinkingReflex arcSpinal trigeminal nucleusMagnetic resonance imagingAnatomyMiddle AgedMedial longitudinal fasciculusMagnetic Resonance ImagingPonsElectric Stimulationmedicine.anatomical_structureFemaleNeurology (clinical)BrainstemPsychologyBrain StemMusclenerve
researchProduct

Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system

2014

Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…

AdultMaleChord (geometry)medicine.medical_specialtyCorneal Wavefront AberrationCorneal Pachymetrygenetic structuresIntraclass correlationScheimpflug principleDiagnostic Techniques OphthalmologicalAstigmatismRefraction OcularCorneaYoung AdultOpticsOphthalmologyPhotographymedicineHumansProspective StudiesCorneal pachymetryDioptreMathematicsObserver VariationWavefrontmedicine.diagnostic_testbusiness.industryReproducibility of ResultsRepeatabilitymedicine.diseaseHealthy Volunteerseye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk

2017

Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…

AdultMaleCorneal PachymetryIntraclass correlationmedicine.medical_treatmentCoefficient of variationBiomedical Engineeringlaw.inventionCorneaYoung Adult03 medical and health sciences0302 clinical medicineOpticslawRefractive surgerymedicineHumansCorneal pachymetryMathematicsKeratometermedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsGeneral MedicineRepeatabilityCorneal topographySpherical aberration030221 ophthalmology & optometryFemaleSurgerybusinessTomography Optical Coherence030217 neurology & neurosurgeryBiomedical engineeringExpert Review of Medical Devices
researchProduct

Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.

2012

Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…

AdultMaleCorneal Wavefront AberrationIntraclass correlationZernike polynomialsmedicine.medical_treatmentRefraction Ocularsymbols.namesakeYoung AdultOpticsRefractive surgeryAberrometrymedicineHumansProspective StudiesMathematicsWavefrontObserver VariationReproducibilitybusiness.industryAberrometryReproducibility of ResultsRepeatabilityWavefront sensorMiddle AgedRefractive ErrorsOphthalmologysymbolsOptometryFemalebusinessAmerican journal of ophthalmology
researchProduct

Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Cohere…

2016

To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 periph…

AdultMaleDaytimeMaterials sciencegenetic structuresCornea03 medical and health sciences0302 clinical medicineOpticsOptical coherence tomographyCorneamedicineHumansProspective StudiesFourier domainObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryEpithelium CornealReproducibility of ResultsMiddle Agedeye diseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsObserver variationbusiness030217 neurology & neurosurgeryTomography Optical CoherenceBiomedical engineeringCornea
researchProduct

The effect of aberrations on objectively assessed image quality and depth of focus

2017

The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…

AdultMaleDepth of focusCorneal Wavefront AberrationAdolescentImage qualityPopulationVisual AcuityComa (optics)Astigmatism050105 experimental psychologyYoung Adult03 medical and health sciences0302 clinical medicineOpticsOptical transfer functionAberrometrymedicineHumansComputer Simulation0501 psychology and cognitive scienceseducationVision OcularRetrospective StudiesMathematicsDepth Perceptioneducation.field_of_studybusiness.industryAberrometry05 social sciencesAstigmatismStrehl ratiomedicine.diseaseSensory SystemsOphthalmologyVisual Perception030221 ophthalmology & optometryFemalebusinessJournal of Vision
researchProduct

Optical factors influencing the amplitude of accommodation

2017

AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…

AdultMaleDepth of focusmedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresZernike polynomialsAmplitude of accommodationAudiologyRefraction Ocular050105 experimental psychologyYoung Adult03 medical and health sciencessymbols.namesake0302 clinical medicineOpticsAberrometrymedicineHumans0501 psychology and cognitive sciencesSpherical aberrationRetrospective Studiesbusiness.industryAberrometry05 social sciencesAccommodation OcularPupilPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseSubjective refractioneye diseasesAmplitude of accommodationSensory SystemsStatistical modelingSpherical aberrationOphthalmologyAmplitude030221 ophthalmology & optometrysymbolsRegression AnalysisFemalePsychologybusinessAccommodationVision Research
researchProduct

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct