Search results for "Crew"
showing 10 items of 93 documents
Finite element analysis of stress concentration between surface coated implants and non surface coated implants - An in vitro study.
2019
Background To determine qualitative comparison in stress distribution between surface coated implants and non surface coated implants using 2 different lengths and vertical, oblique, and lateral forces. Material and Methods 3 dimensional finite element study was carried out at first molar site with 4 surface coated and 4 non surface coated implants using mimic 8.11, solid edge 2004, hypermesh 9.0, and ansys12.1 software. Results The pattern of stress distribution was almost similar between vertical and oblique loading but varied with lateral loads between surface coated and non surface coated implants. As the length of the implants increased stress concentration had no significant variation…
Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Pa…
2019
Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years functional loading. Materials and Methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (Group GS); cemented crown without finishing line (biologically oriented preparation technique) (Group GBOPT); and conventional cemented crown with finishing line (Group GCC). The clinical behavior of each restoration type was analyzed after 3 years functional loading by analyzing radiographic peri-implant b…
Electromagnetic distal targeting system does not reduce the overall operative time of the intramedullary nailing for humeral shaft fractures
2018
Abstract Introduction We aimed to evaluate the efficacy of the use of the electromagnetic distal targeting system in treating humeral shaft fracture. Methods Patients were divided in: Group 1) patients that received a distal locking screw placement following the free-hand technique; Group 2) patients in which the distal locking screw was performed using the SURESHOT device. Results No differences were noted comparing Group 1 (freehand) [71,9 range 40–135 min] to Group 2 (SURESHOT)[70, range 25–125 min]. Conclusion The use of the EM distal targeting system doesn't reduce the overall operative time of the humeral shaft fracture fixation using IMN.
Subjective health complaints, work-related stress and self-efficacy in Norwegian aircrew.
2016
Background The European civilian aviation industry has undergone major changes in the last decade. Despite this, there is little knowledge about work-related stress and subjective health complaints (SHCs) affecting Norwegian aircrew. Aims To investigate the relationships between work-related stress, self-efficacy and SHCs in commercial aircrew in Norway and to explore differences between cockpit and cabin crew. Methods Aircrew members from the three major airlines operating from Norway completed an electronically distributed questionnaire. Linear regression analyses were used to investigate the association between work-related stress, self-efficacy and SHCs. Results There was a 21% response…
Estimated radiation exposure of German commercial airline cabin crew in the years 1960-2003 modeled using dose registry data for 2004-2015.
2016
Exposure to ionizing radiation of cosmic origin is an occupational risk factor in commercial aircrew. In a historic cohort of 26,774 German aircrew, radiation exposure was previously estimated only for cockpit crew using a job-exposure matrix (JEM). Here, a new method for retrospectively estimating cabin crew dose is developed. The German Federal Radiation Registry (SSR) documents individual monthly effective doses for all aircrew. SSR-provided doses on 12,941 aircrew from 2004 to 2015 were used to model cabin crew dose as a function of age, sex, job category, solar activity, and male pilots' dose; the mean annual effective dose was 2.25 mSv (range 0.01–6.39 mSv). In addition to an inverse …
A novel minimally invasive, dorsolateral, tubular partial odontoidectomy and autologous bone augmentation to treat dens pseudarthrosis: cadaveric, 3D…
2017
OBJECTIVE The goal of this study was to demonstrate the clinical and technical nuances of a minimally invasive, dorsolateral, tubular approach for partial odontoidectomy, autologous bone augmentation, and temporary C1–2 fixation to treat dens pseudarthrosis. METHODS A cadaveric feasibility study, a 3D virtual reality reconstruction study, and the subsequent application of this approach in 2 clinical cases are reported. Eight procedures were completed in 4 human cadavers. A minimally invasive, dorsolateral, tubular approach for odontoidectomy was performed with the aid of a tubular retraction system, using a posterolateral incision and an oblique approach angle. Fluoroscopy and postprocedur…
Do palatal implants remain positionally stable under orthodontic load? A clinical radiologic study.
2009
Introduction The aim of this study was to determine the positional stability and success rate of palatally placed length-reduced temporary anchorage devices (LRTADs) (length, 4 or 6 mm). Methods Twenty-two patients (ages, 21-62 years; 14 women, 8 men) were enrolled in the study. Each received 1 LRTAD (Orthosystem, Straumann, Switzerland) placed in the midsagittal palate for multifunctional anchorage tasks. Standardized cephalograms were taken directly after implant placement and at the end of treatment to analyze any implant movements. The cephalometric tracings were superimposed on anterior nasal spine to posterior nasal spine in posterior nasal spine to analyze changes in implant angulati…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws
2017
ObjectiveRecent studies have investigated the role of spinal image guidance for pedicle screw placement. Many authors have observed an elevated placement accuracy and overall improvement of outcome measures. This study assessed a bi-institutional experience following introduction of the Renaissance miniature robot for spinal image guidance in Europe.MethodsThe medical records and radiographs of all patients who underwent robot-guided implantation of spinal instrumentation using the novel system (between October 2011 and March 2015 in Mainz and February 2014 and February 2016 in Regensburg) were reviewed to determine the efficacy and safety of the newly introduced robotic system. Screw posit…
Maintenance of Integrity of Upper Facet Joints during Simulated Percutaneous Pedicle Screw Insertion Using 2D versus 3D Planning
2019
Background No studies have directly and quantitatively compared two-dimensional (2D) and three-dimensional (3D) planning as applied during conventional percutaneous or navigated percutaneous pedicle screw placement. Study Aims This lumbar pedicle-based stabilization simulation study aimed to investigate the risk of upper facet joint violation (FJV) during posterior percutaneous pedicle screw placement with conventional 2D planning of screw implantation (as a model for fluoroscopically guided screws) compared with 3D planning (as used with navigation techniques). Methods The placement of monosegmental lumbar pedicle screws using the data sets of 250 consecutive patients was simulated. Conve…