Search results for "Criterion"
showing 10 items of 171 documents
EMG, heart rate, and accelerometer as estimators of energy expenditure in locomotion.
2014
AB Purpose: Precise measures of energy expenditure (EE) during everyday activities are needed. This study assessed the validity of novel shorts measuring EMG and compared this method with HR and accelerometry (ACC) when estimating EE. Methods: Fifty-four volunteers (39.4 +/- 13.9 yr) performed a maximal treadmill test (3-min loads) including walking with different speeds uphill, downhill, and on level ground and one running load. The data were categorized into all, low, and level loads. EE was measured by indirect calorimetry, whereas HR, ACC, and EMG were measured continuously. EMG from quadriceps (Q) and hamstrings (H) was measured using shorts with textile electrodes. Validity of the met…
Development and Validation of a New Tool for the Assessment and Spiritual Care of Palliative Care Patients
2013
Context. Spiritual assessment tools and interventions based on holistic approaches are needed to promote healing. Such tools must be adapted to the wide cultural backgrounds of contemporary Western society. Objectives. To develop and validate a new brief measure, simultaneously featuring clinical applicability and adequate psychometric properties. The tool uses six initial questions to establish a climate of trust with patients before they complete an eight-item, five-point Likert scale. The questionnaire is based on a model of spirituality generated by the Spanish Society of Palliative Care (SECPAL) Task Force on Spiritual Care (Grupo de Espiritualidad de la SECPAL), which aims to recogniz…
Psychometric properties of the General Self Efficacy-12 Scale in Spanish: general and clinical population samples.
2014
The General Self Efficacy Scale (GSES-12) is a short version of the Sherer’s Self-Efficacy Scale, and evaluates a general dimension and three aspects of self-efficacy: initiative, persistence and effort. The aim of this study is to explore the factorial structure, reliability, and criterion validity of the Spanish adaptation of the GSES-12 in general and clinical populations. The sample was composed of 714 volunteers (332 from the clinical population). Results of the principal components analysis yielded a 3-factor structure that was later confirmed through Confirmatory Factor Analysis. Moreover, this study shows good internal consistency and testretest values, and differences in self-effic…
Validation of the Italian version of the Burn Specific Health Scale-Brief
2014
Introduction A growing awareness of psychological and functional impairment due to burns have led to the development of specific instruments to evaluate Quality of Life in this population, such as the Burn Specific Health Scale - Brief (BSHS-B), whose psychometric properties have been consistently verified. The aim of this study was to translate the BSHS-B into Italian and to investigate its reliability and validity. Methods Translation procedures were carried out according to accepted standards. Internal reliability was assessed using Cronbach's alpha coefficient. Concurrent validity was evaluated through correlations between the BSHS-B and the Short-Form 36 Health Survey (SF-36), the Self…
The Revised Asthma Problem Behavior Checklist: Adaptation for Use in Spanish Asthmatic Patients
1997
Behavioral problems associated with asthma management were examined in a group of 100 adult Spanish outpatients with asthma (57 women, 43 men; 17-69 years of age). All of them completed a Spanish version of the Revised Asthma Problem Behavior Checklist (RAPBC). Data about duration, severity, and self-management of asthma (self-efficacy expectancies and health care utilization), as well as dyspnea and FEV1, were also recorded. The highest-reliability Cronbach alpha indices were for the criteria related to emotions and behaviors that could precipitate asthma attacks. Concurrent criterion validity was examined first by Pearson correlations between the RAPBC scores and clinical data about asthm…
Concurrent Criterion-related Validity, Reliability, and Responsiveness to Treatment of the Figure-of-Four Position for Measurement of Anterior Hip Jo…
2018
Abstract Objective The objective of this study was to examine the intra- and intertester reliability, concurrent criterion-related validity, and responsiveness to treatment of the “figure-of-four” position. Methods A total of 52 asymptomatic male soccer players participated in this study. The intraclass correlation coefficient (2, 1) was used to determine intra- and intertester reliability of the figure-of-four position. Pearson product moment correlation coefficients examining the association between the figure-of-four position and goniometric measurements of hip extension and external rotation were used to establish concurrent validity. To evaluate responsiveness to treatment, the figure-…
Confirmatory factor analysis of the Patient Assessment of Constipation-Symptoms (PAC-SYM) among patients with chronic constipation.
2015
Background and aim: PAC-SYM is widely adopted to asses constipation severity. However, it has been validated in a small sample, few items have been included based on expert opinion and not on empirical grounds, and its factor structure has never been replicated. We aimed at evaluating the psychometric properties of PAC-SYM in patients with chronic constipation. Methods: We enrolled 2,203 outpatients with chronic constipation in two waves. We used wave I sample to test the psychometric properties of the PAC-SYM and wave II sample to cross-validate its factor structure, to assess criterion validity, responsiveness to clinical change, and its minimal clinically important difference. Results: O…
Prospective randomized comparison of short-access mother-baby cholangioscopy versus direct cholangioscopy with ultraslim gastroscopes
2012
Mother-baby technologies, the criterion standard for cholangioscopy, have several limitations. A novel, short-access, mother-baby (SAMBA) system may improve this technique. Direct cholangioscopy (DC) was recently developed as an alternative to mother-baby cholangioscopy.Comparison of success rates with SAMBA and DC.Single-center, randomized, controlled trial.Academic tertiary-care referral center.Sixty patients with suspected cholangiopathies randomized to either SAMBA (n = 30) or DC (n = 30).Cholangioscopy under deep sedation.Technical success rate of diagnostic or therapeutic procedure.A total of 24 and 21 diagnostic procedures were performed in the SAMBA and DC groups, respectively. Ther…
Screening for generalized anxiety disorder in Spanish primary care centers with the GAD-7.
2017
The aim of the study was to determine the criterion validity of a computerized version of the General Anxiety Disorder-7 (GAD-7) questionnaire to detect general anxiety disorder in Spanish primary care centers. A total of 178 patients completed the GAD-7 and were administered the Composite International Diagnostic Interview (CIDI) for DSM-IV Axis I Disorders, which was used as a reference standard. Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios were calculated. A cut-off of 10 yielded a sensitivity of .87, a specificity of .78, a positive predictive value of .93, a negative predictive value of .64, a positive likelihood ratio o…
Diagnosing ICD-10 depressive episodes: superior criterion validity of the Patient Health Questionnaire.
2004
<i>Background:</i> Diagnosing and monitoring depression in primary care remains an issue of significant public health concern. Clinicians and researchers need to know if any one screening instrument is superior to the others in diagnosing ICD-10 depressive episodes. This study aimed to examine the criterion validity for diagnosing ICD-10 depressive episodes of the Patient Health Questionnaire (PHQ) in comparison with 2 well-established instruments, the Hospital Anxiety and Depression Scale (HADS), and the WHO Well-Being Index 5 (WBI-5). <i>Methods:</i> Five hundred and one medical outpatients completed the questionnaires and had a clinical interview. The presence of …