Search results for "Cyclodextrin"

showing 10 items of 266 documents

A new heuristic algorithm for the analysis of NMRD dispersion curves

Regression analysis of the NMRD dispersion curves obtained by the FFC-NMR relaxometric technique involves several conceptual and practical issues, which must be carefully addressed in order to gain reliable information on the system studied. Indeed, particular caution is needed when the FFC technique is applied to the investigation of complex systems such as polymeric matrixes, porous materials, food samples, and so on. In these cases, and in general whenever a rigorous approach based on a suitable physical modelization of the system is not available, data analysis must be performed by means of a “model–free” approach. Moving forward from previous literature, in the present communication we…

CyclodextrinsSettore AGR/13 - Chimica AgrariaSettore CHIM/06 - Chimica OrganicaRelaxometryHeuristic AlgorithmFFC-NMRSettore CHIM/02 - Chimica Fisica
researchProduct

Comparative evaluation of liquid chromatography versus gas chromatography using a β-cyclodextrin stationary phase for the determination of BTEX in oc…

2009

An HPLC method for the determination of benzene, toluene, ethylbenzene and o-xylene, m-xylene and p-xylene in occupational environments was developed and compared with a GC-MS method. Chromatographic analysis using a beta-cyclodextrin stationary phase was performed after active and passive air sampling by adsorption on activated charcoal and pressurized fluid extraction. The analytes were completely separated and quantified using both methods, although GC-MS provided better resolutions and lower detection limits than HPLC. The HPLC method was unsuccessfully applied to the determination of benzene in real samples because its sensitivity was too low. Both methods were applied to the analysis …

Detection limitChromatography GasChromatographybeta-CyclodextrinsAnalytical chemistryBenzeneBeta-CyclodextrinsBTEXXylenesHigh-performance liquid chromatographyEthylbenzeneAnalytical Chemistrychemistry.chemical_compoundCertified reference materialschemistryOccupational ExposureBenzene DerivativesGas chromatographyGas chromatography–mass spectrometryChromatography LiquidTolueneTalanta
researchProduct

Simultaneous determination of third-generation synthetic cannabinoids in oral fluids using cyclodextrin-silica porous sorbents

2022

Abstract A microporous material made of cyclodextrin units covalently immobilized into a silica network has found an innovative bioanalytical application in the sample clean-up and simultaneous isolation of three synthetic cannabinoids (ADB-CHMICA, MMB-CHMICA, and MDMB-CHMCZCA) from human oral fluid through solid-phase extraction. The subsequent quantitation is carried out using liquid chromatography coupled to fluorescence detection. The optimized experimental procedure gives recoveries ranging from 76% to 96% in oral fluid samples spiked with the studied cannabinoids at the µg L-1 level. High selectivity is obtained through the extraction procedure due to the presence of cyclodextrin in t…

Detection limitchemistry.chemical_classificationBioanalysisChromatographyCyclodextrinExtraction (chemistry)SorptionMicroporous materialAnalytical ChemistrychemistrySynthetic cannabinoidsmedicinePorous mediumSpectroscopymedicine.drugMicrochemical Journal
researchProduct

Chromatographic Separation of Cresol Isomers by a β‐Cyclodextrin: Application for the Determination of Volatile Phenols in Alcoholic Beverages

2006

Abstract The chromatographic separation of o‐cresol, m‐cresol, and p‐cresol by using β‐cyclodextrin as a chiral reagent has been studied. Conditions for the chromatographic separation of these isomers by using the cyclodextrin in the mobile phase or bonded in the stationary phase were optimized, and both procedures provided good results for the resolution of the chromatographic peaks. The use of fluorimetric detection (λexc 275 nm λem 300 nm) allows detection and quantification limits of the µg/L for eight studied phenols by using both procedures. The determination of volatile phenols in alcoholic beverages must be carried out using the cyclodextrin in the mobile phase because of the co‐elu…

Detection limitchemistry.chemical_classificationChromatographyCyclodextrinElutionBiochemistry (medical)Clinical BiochemistryFluorescence spectrometryCresolBiochemistryAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundchemistryReagentparasitic diseasesElectrochemistrymedicineOrganic chemistryPhenolsSpectroscopymedicine.drugAnalytical Letters
researchProduct

Determination of the UV filters worldwide authorised in sunscreens by high-performance liquid chromatography

2001

Simultaneous determination of organic UV filters worldwide authorised in sunscreen formulations was performed by HPLC with UV spectrophotometric detection. The filters determined were: benzophenone-4, benzophenone-3, butyl methoxydibenzoylmethane, octyl dimethyl PABA, octyl methoxycinnamate, homosalate and octyl salicylate. A C18 stationary phase and an isocratic mobile phase of ethanol-water-acetic acid (70:29.5:0.5) containing 65.4 mM of hydroxypropyl-beta-cyclodextrin, were used with a flow-rate of 0.6 ml/min. UV measurements were carried out at 313 nm. The time required for the analysis was 20 min and the limits of detection were between 1.5 and 2.3 mg/l. The procedure proposed provides…

Detection limitchemistry.chemical_classificationChromatographyCyclodextrinOrganic ChemistryOctyl methoxycinnamateGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryHomosalatechemistry.chemical_compoundchemistrymedicineOctyl salicylateQuantitative analysis (chemistry)medicine.drugJournal of Chromatography A
researchProduct

Two components hydrogels formed by host-guest interactions

Dicationic imidazolium salts cyclodextrins hydrogelsSettore CHIM/06 - Chimica Organica
researchProduct

Peracetylated β‐cyclodextrin as solubilizer of arylphosphines in supercritical carbon dioxide

2006

Abstract Effect of peracetylated β-cyclodextrin on the solubility of diphenyl(4-phenylphenyl)phosphine in supercritical carbon dioxide medium has been investigated. As shown by gravimetric measurements, the presence of cyclodextrin (CD) (1 equivalent) allows to increase the solubility of phosphine (P) in supercritical carbon dioxide (scCO 2 ) (40 °C, 35.2 MPa, nominal system density 0.89 g/mL). This solubility enhancement was attributed to host–guest interactions in scCO 2 as the P was recovered in the form of an inclusion complex. Furthermore, a diffuse reflectance spectroscopy study on the samples recovered after the experiments and on various CD/P solid mixtures obtained by co-grinding i…

Diffuse reflectance infrared fourier transformGeneral Chemical EngineeringInorganic chemistry010402 general chemistry01 natural scienceschemistry.chemical_compoundGravimetric measurementDifferential scanning calorimetryDifferential scanning calorimetryDiffuse reflectance spectroscopy[CHIM]Chemical SciencesPhysical and Theoretical ChemistrySolubilityComputingMilieux_MISCELLANEOUSchemistry.chemical_classificationSupercritical carbon dioxideCyclodextrin010405 organic chemistry[CHIM.MATE]Chemical Sciences/Material chemistryCondensed Matter Physics0104 chemical sciences[CHIM.THEO]Chemical Sciences/Theoretical and/or physical chemistrySolubilityCarbon dioxidechemistryCarbon dioxideGravimetric analysisPhosphinePhosphine
researchProduct

In vitro study of N-succinyl chitosan for targeted delivery of 5-aminosalicylic acid to colon

2011

In vitro study on N-succinyl chitosan and chitosan (control) matrices for selective colon delivery of 5-aminosalicylic acid is described. Matrices containing β-cyclodextrin were also prepared. As shown by DSC analyses, the drug was successfully loaded into the matrices reaching up to 95% entrapment efficiency. Swelling and drug release were studied at pH 1.2, pH 7.4, and in a pH gradient medium to simulate the gastro-intestinal transit. Main result of this study was a higher capability of N-succinyl chitosan alone to better control drug release in the simulated gastro-intestinal transit: N-succinyl chitosan gave the lowest release in acid medium (≅15%) and the highest in alkaline environmen…

Drugchemistry.chemical_classificationAminosalicylic acidPolymers and PlasticsCyclodextrinmedia_common.quotation_subjectOrganic Chemistrytechnology industry and agricultureAdhesioncarbohydrates (lipids)Chitosanchemistry.chemical_compoundchemistryPolymer chemistryMaterials ChemistryPh gradientmedicineIn vitro studySwellingmedicine.symptommedia_commonNuclear chemistryCarbohydrate Polymers
researchProduct

Adsorption of a dye on clay and sand. Use of cyclodextrins as solubility-enhancement agents.

2007

Abstract Laboratory-scale studies were aimed at elucidating the physico-chemical aspects on the removal process of crystal violet (CV) from waters and solid substrates. The laponite clay (RD) and sand were chosen for the double aim at investigating them as CV adsorbents for water treatment and as substrates which mime the soil components. Sand is very effective in removing CV from waters. The cyclodextrins (CDs) were exploited as solubility-enhancement agents to remove CV from the solid substrates. They are powerful solvent media because they extract the CV from sand forming water-soluble CV/CD inclusion complexes and do not show affinity for sand. Optimum performance was shown by the modif…

Environmental EngineeringDyeHealth Toxicology and MutagenesisSolid substrateInclusion compoundWater Purificationchemistry.chemical_compoundAdsorptionCyclodextrinEnvironmental ChemistryCrystal violetSolubilityEquilibrium constantSettore CHIM/02 - Chimica Fisicachemistry.chemical_classificationCyclodextrinsInclusion complexChromatographyCyclodextrinChemistryPublic Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistrySilicon DioxidePollutionSolventModels ChemicalSolubilityClayThermodynamicsWater treatmentAluminum SilicatesGentian VioletAdsorptionFlushing agentWater Pollutants ChemicalNuclear chemistryChemosphere
researchProduct

Design, characterization and comparison of materials based on β and γ cyclodextrin covalently connected to microporous silica for environmental analy…

2018

Abstract Determination of organic pollutants in environmental samples presents great difficulties due to the lack of sensitivity and selectivity in many of the existing analytical methods. In this work, the efficiency of materials based on silica structures containing bounded γ-cyclodextrin has been evaluated to determinate phenolic compounds and polycyclic aromatic hydrocarbons in air and water samples, respectively, in comparison with materials made of β-cyclodextrin. According to the results obtained for the material characterization, the new γ-cyclodextrin solid phase does not apparently present any porosity when used in air samples, but it has been shown to work efficiently for the pre…

Environmental analysisInorganic chemistry010402 general chemistry01 natural sciencesBiochemistryGas Chromatography-Mass SpectrometryAnalytical ChemistryLimit of DetectionPhase (matter)DesorptionPolycyclic Aromatic HydrocarbonsPorositychemistry.chemical_classificationAir PollutantsChromatographyCyclodextrinSolid Phase Extractionbeta-Cyclodextrins010401 analytical chemistryOrganic ChemistryGeneral MedicineMicroporous materialSilicon Dioxide0104 chemical sciencesCharacterization (materials science)chemistrySelectivityPorosityWater Pollutants Chemicalgamma-CyclodextrinsJournal of Chromatography A
researchProduct